GB 16556-2025: Respiratory protection - Self-contained open-circuit compressed air breathing apparatus
Status: Valid

GB 16556: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB 16556-2025English719 Add to Cart 6 days [Need to translate] Respiratory protection - Self-contained open-circuit compressed air breathing apparatus Valid GB 16556-2025
GB/T 16556-2007English759 Add to Cart 5 days [Need to translate] self-contained open-circuit compressed air breathing apparatus Valid GB/T 16556-2007
GB 16556-1996English399 Add to Cart 3 days [Need to translate] Self-contained compressed air breathing apparatus Obsolete GB 16556-1996

PDF similar to GB 16556-2025


Standard similar to GB 16556-2025

GB 14866   GB/T 18664   GB/T 20097   GB 13641   GB 18664   

Basic data

Standard ID GB 16556-2025 (GB16556-2025)
Description (Translated English) Respiratory protection - Self-contained open-circuit compressed air breathing apparatus
Sector / Industry National Standard
Classification of Chinese Standard C73
Classification of International Standard 13.340.30
Word Count Estimation 36,338
Date of Issue 2025-08-29
Date of Implementation 2026-09-01
Older Standard (superseded by this standard) GB/T 16556-2007
Issuing agency(ies) State Administration for Market Regulation; Standardization Administration of China

GB 16556-2025: Respiratory protection - Self-contained open-circuit compressed air breathing apparatus


---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GB16556-2025
ICS 13.340.30 CCSC73 National Standards of the People's Republic of China Replaces GB/T 16556-2007 Self-contained open-circuit compressed air breathing apparatus Implemented on 2026-09-01 State Administration for Market Regulation The State Administration for Standardization issued a statement.

Table of Contents

Preface III 1.Scope 1 2 Normative References 1 3.Terms and Definitions 1 4.Classification and Labeling 2 5.Technical Requirements 2 6.Test Method 11 7.Labeling, packaging, and manufacturer-provided information 24 Appendix A (Normative) Flame Engulfment Test Method 26 References 31

Foreword

This document complies with the provisions of GB/T 1.1-2020 "Standardization Work Guidelines Part 1.Structure and Drafting Rules of Standardization Documents". Drafting. This document replaces GB/T 16556-2007 "Self-Contained Open-Circuit Compressed Air Breathing Apparatus". Compared with GB/T 16556-2007, the following changes are made. Aside from structural adjustments and editorial changes, the main technical changes are as follows. a) The classification and labeling have been changed (see Chapter 4, Chapter 4 of the.2007 edition); b) The technical requirements for expiratory resistance have been changed (see 5.5.2, 5.21.2 in the.2007 edition); c) Requirements for the overall flame retardancy of emergency air respirators and flame engulfment test methods have been added (see 5.8.2.2, 6.9.4, and Appendix A); d) Requirements and test methods for the water immersion resistance of respirators have been added (see 5.10 and 6.11); e) The requirements for mask leakage rate, airtightness, and impact resistance have been changed (see 5.11, 5.8.2, 5.8.4, and 5.8.6 of the.2007 edition); f) Increased requirements for the protection of face shield lenses against high-speed particle impacts (see 5.11); g) The technical requirements and test methods for pressure regulator safety valves have been revised (see 5.19.2, 6.16, 5.16.2 and 6.10 in the.2007 edition); h) The explosion-proof technical requirements for electronic pressure gauges and electronic alarms have been revised (see 5.20.3, 5.21.3, and 5.17.3 and 5.18.3 in the.2007 edition); i) The temperature and flame adaptability test methods have been changed (see 6.9, 6.5 in the.2007 edition); j) Technical requirements and test methods for medium-pressure auxiliary joints have been added (see 5.22, 6.14.2); k) Added technical requirements and test methods for rapid inflation devices (see 5.23, 6.19); l) Technical requirements and test methods for quick-change gas cylinder devices have been added (see 5.24 and 6.20); m) Added technical requirements and test methods for pressure head-up display devices (see 5.25, 6.21); n) A test method for low-temperature alarm performance of alarm devices has been added (see 6.18.3). Please note that some content in this document may involve patents. The issuing organization of this document assumes no responsibility for identifying patents. This document was proposed and is under the jurisdiction of the Ministry of Emergency Management of the People's Republic of China. The release history of this document and the document it replaces is as follows. ---First published as GB 16556-1996 in.1996, and first revised as GB/T 16556-2007 in.2007; ---This is the second revision. Self-contained open-circuit compressed air breathing apparatus 1.Scope This document specifies the technical requirements, labeling, packaging, and manufacturer information for self-contained open-circuit compressed air breathing apparatus, and provides a classification system. The symbols and tags describe the corresponding test methods. This document applies to self-contained open-circuit compressed air breathing apparatus (hereinafter referred to as air breathing apparatus) for industrial and emergency use. This document does not apply to closed-circuit breathing apparatus, diving breathing apparatus, escape breathing apparatus, and negative pressure breathing apparatus.

2 Normative references

The contents of the following documents, through normative references within the text, constitute essential provisions of this document. Dated citations are not included. For references to documents, only the version corresponding to that date applies to this document; for undated references, the latest version (including all amendments) applies. This document. GB/T 1226 General Pressure Gauges GB 2626-2019 Respiratory Protection - Self-priming Filtering Respirators for Particulate Matter GB 2890-2022 Respiratory Protective Self-priming Filtering Gas Mask GB/T 3836.1 Explosive Atmospheres – Part 1.General Requirements for Equipment GB/T 3836.4 Explosive atmospheres – Part 4.Equipment protected by intrinsic safety type “i” GB/T 4208-2017 Degrees of protection provided by enclosures (IP code) GB/T 5099.1 Seamless steel gas cylinders - Part 1.Steel cylinders with a tensile strength of less than 1100 MPa after quenching and tempering. GB/T 5099.3 Seamless steel gas cylinders - Part 3.Normalized steel cylinders GB/T 5099.4 Seamless steel gas cylinders - Part 4.Seamless stainless steel gas cylinders GB/T 7307-2001 55° Non-sealing Pipe Threads GB/T 12903 Terminology for Personal Protective Equipment GB 14866-2023 General Technical Specification for Eye and Face Protective Equipment GB/T 23465-2009 Practical Performance Evaluation of Respiratory Protective Equipment GB/T 28053 Aluminum Alloy Liner Carbon Fiber Fully Wound Gas Cylinder GB 31975 Technical requirements for compressed air for respiratory protection GB/T 32166.2-2015 Personal Protective Equipment - Eye and Face Protection; Occupational Eye and Face Protection - Part 2.Measurement Methods GB/T 34527 Technical requirements for cylinder valves for air respirators 3.Terms and Definitions The terms and definitions defined in GB/T 12903 and the following terms and definitions apply to this document. 3.1 By ensuring a tight seal between the mask and the wearer's face, the wearer's respiratory organs, eyes, and face are kept away from toxic or oxygen-deficient air. A respirator that completely isolates the user, who carries their own clean compressed air as a breathing source, and whose exhaled air is directly released into the ambient air. 3.2 and emergency services A self-contained open-circuit compressed air breathing apparatus used by personnel undertaking emergency tasks such as fire fighting, hazardous chemical disposal, and rescue. 3.3 In addition to the areas where emergency air respirators are applicable, they are also suitable for use in mining, petrochemical, industrial and commercial, metallurgical, transportation, municipal construction, public utilities, and other fields. A self-contained open-circuit compressed air breathing apparatus used by workers in various industries. 3.4 static pressure The pressure inside the mask cavity when the air supply valve positive pressure device is turned on and the air circuit of the air respirator is balanced. 4.Classification and Labeling 4.1 Classification 4.1.1 Classification by Applicable Occasion According to their applicable occasions, air respirators are divided into. a) Industrial air respirator, marking code. GY; b) Emergency air respirator, marking code. YJ. 4.1.2 Classification by Cylinder Material According to the material of the air cylinder, air respirators are divided into. a) Seamless steel gas cylinder, marked with code. G; b) Aluminum alloy liner carbon fiber fully wrapped gas cylinder (referred to as "composite gas cylinder"), marking code. F. 4.1.3 Classification by nominal volume of gas cylinders The nominal volume of the air cylinder for an air respirator should be no less than 3L and no more than 12L. The cylinder can be marked with a value of 3 based on its actual nominal volume. 4.7, 6.8, 8, 9, 12, etc. 4.2 Marking Product markings include the product name, this document number, applicable category of the air respirator, cylinder material category, nominal cylinder volume, and cylinder number. It consists of six parts, including nominal work pressure. Example 1.Emergency air respirator, using an aluminum alloy liner and carbon fiber fully wound cylinder, with a nominal cylinder volume of 9L and a nominal working pressure of 35MPa, marked as follows. The specification is. Self-contained open-circuit compressed air breathing apparatus GB 16556-YJ-F-9-35MPa. Example 2.An industrial air respirator, using a seamless steel cylinder with a nominal volume of 6.8L and a nominal working pressure of 30MPa, is marked as. self-contained open-circuit type. Compressed air breathing apparatus GB 16556-GY-G-6.8-30MPa, or self-contained open-circuit compressed air breathing apparatus GB 16556-GY-G-6.8-30MPa. 5 Technical Requirements 5.1 Materials When inspected according to the methods specified in 6.3 and 6.8, the materials used in air-breathing apparatus shall meet the following requirements. a) The materials used in air respirators should have sufficient mechanical strength, fatigue resistance, and aging resistance, and should not fail to function properly during normal use.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB 16556-2025_English be delivered?

Answer: Upon your order, we will start to translate GB 16556-2025_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 6 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB 16556-2025_English with my colleagues?

Answer: Yes. The purchased PDF of GB 16556-2025_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB 16556-2025?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB 16556-2025 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.