US$209.00 ยท In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. LY/T 1765-2008: Technical regulation for forest fire lookouts observation
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| LY/T 1765-2008 | English | 209 |
Add to Cart
|
3 days [Need to translate]
|
Technical regulation for forest fire lookouts observation
| |
LY/T 1765-2008
|
PDF similar to LY/T 1765-2008
Basic data | Standard ID | LY/T 1765-2008 (LY/T1765-2008) | | Description (Translated English) | Technical regulation for forest fire lookouts observation | | Sector / Industry | Forestry Industry Standard (Recommended) | | Classification of Chinese Standard | B65 | | Classification of International Standard | 65.020 | | Word Count Estimation | 6,696 | | Date of Issue | 2008-09-03 | | Date of Implementation | 2008-12-01 | | Quoted Standard | LY/T 1679-2006 | | Regulation (derived from) | Industry standard filing Notice No. 10 of 2008 | | Issuing agency(ies) | State Forestry Administration | | Summary | This standard specifies the forest fire forest fire observation floor observatory scope, terms and definitions, basic requirements, lookout, fire reports. This standard applies to stare across the country of Forest Fire Lookout (tower) lookout observation. |
LY/T 1765-2008: Technical regulation for forest fire lookouts observation---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Technical regulation for forest fire lookouts observation
ICS 65.020
B65
People's Republic of China Forestry Industry Standard
Technical regulations for observing observation of forest fire prevention observatory
Released on.2008-09-03
2008-12-01 implementation
State Forestry Administration released
Foreword
This standard is proposed and managed by the State Forestry Administration.
This standard was drafted. Heilongjiang Provincial Forest Protection Research Institute.
The main drafters of this standard. Wang Yaohua, Bai Xuefeng, Wang Xianxiang, Xu Yiling, Cai Zhiyong, Li Hui, Yu Wennan, Li Huidong, Sun Pingyan, Yu Zhan
Yu, Liu Futang, Huang Yizhe, Liu Shixiong, Zeng Qingfeng, Bi Yongcai.
Technical regulations for observing observation of forest fire prevention observatory
1 Scope
This standard specifies the scope, terminology and definitions, basic requirements, expectations, and fire reports of forest fire prevention ground gazebo forest fire observation.
This standard applies to the observation of the forest fire prevention observation platform (tower) in all forest areas of the country.
2 Normative references
The terms in the following documents become the terms of this standard by reference to this standard. All dated references, followed by all
Modifications (not including errata content) or revisions do not apply to this standard, however, parties to agreements based on this standard are encouraged to study
Is it possible to use the latest version of these files? For undated references, the latest edition applies to this standard.
LY/T 1679-2006 Technical Regulations for Forest Fire Fighting
3 Terms and definitions
The terms and definitions established by LY/T 1679-2006 and the following terms apply to this standard.
3.1
A ground building set up in the forest area dedicated to observing forest fires.
3.2
An open flame that has not been completely extinguished and is re-ignited by the influence of the wind, also called a resurgence of fire.
3.3
Forest fires caused directly or indirectly by lightning strikes are mostly caused by dry thunderstorms.
3.4
The smoke produced by the combustion of combustibles in the forest area is vertical or at a certain angle of inclination.
3.5
The initial combustion of the combustibles in the forest area, the starting point of the spread of the fire source, or the place where the fire in the fire has been re-burned.
4 basic requirements
4.1 Lookout mission
4.1.1 Identify the fire, determine the position of the fireworks, and report it to the competent department in time.
4.1.2 In the fire, continuous observation, and provide fire information to the superior authorities at any time. And record the fire situation.
4.1.3 Post-fire reports and records.
4.2 Lookout equipment
4.2.1 Observation instruments. compasses, telescopes, forest fire detectors, video monitors, infrared cameras, etc.
4.2.2 Communication equipment. telephones, walkie-talkies, short-wave radios, etc.
4.2.3 Other and ancillary facilities. digital camera, sun visor, timer, various charts and power supply equipment, simple meteorological element observer, anti-
Wind, rain, heating, etc.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of LY/T 1765-2008_English be delivered?Answer: Upon your order, we will start to translate LY/T 1765-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of LY/T 1765-2008_English with my colleagues?Answer: Yes. The purchased PDF of LY/T 1765-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|