HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (25 Oct 2025)

GB/T 39488-2020 English PDF

US$489.00 · In stock
Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 39488-2020: Safety and control devices for gas burners and gas-burning appliances - Particular requirements - Electronic type gas and air ratio control system
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 39488-2020English489 Add to Cart 5 days [Need to translate] Safety and control devices for gas burners and gas-burning appliances - Particular requirements - Electronic type gas and air ratio control system Valid GB/T 39488-2020

PDF similar to GB/T 39488-2020


Standard similar to GB/T 39488-2020

GB/T 41317   GB/T 38603   GB/T 39434   GB/T 39493   GB/T 39485   

Basic data

Standard ID GB/T 39488-2020 (GB/T39488-2020)
Description (Translated English) Safety and control devices for gas burners and gas-burning appliances - Particular requirements - Electronic type gas and air ratio control system
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard P45
Classification of International Standard 91.140
Word Count Estimation 26,260
Date of Issue 2020-11-19
Date of Implementation 2021-10-01
Regulation (derived from) National Standard Announcement No. 26 of 2020
Issuing agency(ies) State Administration for Market Regulation, China National Standardization Administration

GB/T 39488-2020: Safety and control devices for gas burners and gas-burning appliances - Particular requirements - Electronic type gas and air ratio control system


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Safety and control devices for gas burners and burning appliances.Special requirements.Electronic gas and air ratio control system) ICS 91.140 P45 National Standards of People's Republic of China Safety and control devices for gas burners and burning appliances Special requirements electronic gas and air proportional control system Released on 2020-11-19 Implemented on 2021-10-01 State Administration for Market Regulation Issued by the National Standardization Management Committee

Table of contents

Preface Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 1 4 Structure and materials 2 4.1 General requirements 2 4.2 Structure 3 4.3 Material 3 4.4 Gas connection 3 4.5 Electronic components 3 5 Requirements 4 5.1 General requirements 4 5.2 Component requirements 4 5.3 Performance requirements 4 6 Test method 6 6.1 Test conditions 6 6.2 Component test 6 6.3 Performance test 6 7 Inspection rules 7 7.1 Factory inspection 7 7.2 Type inspection 8 8 Signs, installation and operating instructions 10 8.1 Sign 10 8.2 Installation and operating instructions 10 8.3 Warning notice 10 9 Packaging, transportation and storage 10 Appendix A (informative appendix) Structural changes of this standard compared with ISO 23552-1.2007 11 Appendix B (informative appendix) Technical differences between this standard and ISO 23552-1.2007 and their reasons 12 Appendix C (informative appendix) Correspondence table 14 for clauses supporting the basic requirements of GB 16914-2012 Appendix D (Normative Appendix) Special requirements for single position feedback potentiometers in electromechanical regulators 16 Appendix E (Normative Appendix) Manufacturer's Statement on Sensors and Regulators and ERC Accuracy 17 Reference 20

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard uses the redrafting law to amend and adopt ISO 23552-1.2007 "Gas and/or oil burners and gas and/or oil appliances Particular requirements for safety and control devices for use. Part 1.Electronic gas/air ratio controller. Compared with ISO 23552-1.2007, this standard has many adjustments in structure. Appendix A lists this standard and ISO 23552-1. The.2007 chapter number comparison list. Compared with ISO 23552-1.2007, there are technical differences between this standard and the clauses involved in these differences have been passed in the outer margins. The set vertical single line (|) is marked, and a list of the corresponding technical differences and their reasons is given in Appendix B. This standard is consistent with GB 16914-2012 "Safety Technical Conditions for Gas Burning Appliances", and the support of this standard is given in Appendix C Correspondence table of GB 16914-2012 basic requirements. This standard also made the following editorial changes. --- Amend the standard name to "Special requirements for safety and control devices for gas burners and combustion appliances, electronic gas and air Gas proportional control system"; ---Chapter 4 of ISO 23552-1.2007 is deleted. This standard was proposed and managed by the Ministry of Housing and Urban-Rural Development of the People's Republic of China. Drafting organizations of this standard. China Municipal Engineering North China Design and Research Institute Co., Ltd., Guangzhou Jingding Electrical Technology Co., Ltd., Site Gas Control System Manufacturing (Suzhou) Co., Ltd., Shanghai Qiaoheng Industrial Co., Ltd., Shaoxing Eco Electric Co., Ltd., Io Smith (Chinese China) Water Heater Co., Ltd., Qingdao Economic and Technological Development Zone Haier Water Heater Co., Ltd., Guangdong Wanhe Thermal Energy Technology Co., Ltd., Zhejiang Sanguo Precision Electromechanical Co., Ltd., Zhanjiang CITIC Solenoid Valve Co., Ltd., Guangdong Evergreen (Group) Co., Ltd., Zhejiang Shuaifeng Electric Co., Ltd. The company, Wuhu Midea Kitchen and Bathroom Appliance Manufacturing Co., Ltd., Ariston Thermal Products (China) Co., Ltd., and Yushidu Intelligent Equipment (Tianjin) have Limited company, National Gas Appliance Quality Supervision and Inspection Center. The main drafters of this standard. Qu Yanhong, Pang Zhiyong, Ling Juan, Bao Haiqiang, Du Jianming, Qiu Bu, Liu Yun, Xie Yi, Li Pingyou, Ye Yanghai, Yao Biaocheng, Shao Yuji, Xu Guoping, Zhang Yi, Gao Chunqing, Yang Lijie, Zhang Mengting. Safety and control devices for gas burners and burning appliances Special requirements electronic gas to air ratio Control System

1 Scope

This standard specifies the electronic gas to air ratio control for burners and burning appliances that use urban gas specified in GB/T 13611. The structure and materials, requirements, test methods, inspection rules, signs, installation and operation instructions, packaging, transportation and storage of the control system. This standard applies to gas water heaters, gas heating water heaters, gas burners/machines, gas heaters that are controlled by closed loops and used for premixed combustion. Electronic gas and air ratio control system for heaters, gas boilers and other gas burning appliances or combustion equipment.

2 Normative references

The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this document. For undated references, the latest version (including all amendments) applies to this document. GB/T 2828.1 Sampling inspection procedure by attributes Part 1.Batch inspection sampling plan retrieved by acceptance quality limit (AQL) GB/T 4208 enclosure protection class (IP code) (GB/T 4208-2017, IEC 60529.2013, IDT) GB/T 13611 Classification and basic characteristics of urban gas GB/T 14536.1-2008 Household and similar electric automatic controllers Part 1.General requirements [IEC 60730-1.2003(Ed3.1), IDT] GB/T 14536.6-2008 Household and similar electric automatic controllers, special requirements for burner electric automatic control systems (IEC 60730-2-5.2004, IDT) GB/T 30597-2014 General requirements for safety and control devices for gas burners and burning appliances (ISO 23550.2011, MOD)

3 Terms and definitions

The following terms and definitions defined in GB/T 30597, GB/T 14536.1, GB/T 14536.6, and the following apply to this document. 3.1 Electronic gas and air proportional control system Composed of an electronic control module, an actuator (including at least a gas regulating unit and an air flow regulating unit), and a designated feedback signal, The closed-loop control system used to adjust the ratio of gas and air is shown in Figure 1. 3.2 Electronic control module The electronic main control module with all input/output control components is shown in Figure 1. 3.3 Define state System failure enters a safe state with one of the following characteristics.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 39488-2020_English be delivered?

Answer: Upon your order, we will start to translate GB/T 39488-2020_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 39488-2020_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 39488-2020_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.