US$559.00 · In stock Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 39493-2020: (Safety and control devices for gas burners and burning appliances Special requirements Pressure regulating devices) Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 39493-2020 | English | 559 |
Add to Cart
|
5 days [Need to translate]
|
(Safety and control devices for gas burners and burning appliances Special requirements Pressure regulating devices)
| Valid |
GB/T 39493-2020
|
PDF similar to GB/T 39493-2020
Basic data | Standard ID | GB/T 39493-2020 (GB/T39493-2020) | | Description (Translated English) | (Safety and control devices for gas burners and burning appliances Special requirements Pressure regulating devices) | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | P45 | | Word Count Estimation | 30,342 | | Date of Issue | 2020-11-19 | | Date of Implementation | 2021-10-01 | | Regulation (derived from) | National Standard Announcement No. 26 of 2020 | | Issuing agency(ies) | State Administration for Market Regulation, China National Standardization Administration |
GB/T 39493-2020: (Safety and control devices for gas burners and burning appliances Special requirements Pressure regulating devices) ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Safety and control devices for gas burners and burning appliances Special requirements Pressure regulating devices)
ICS 91.140
P45
National Standards of People's Republic of China
Safety and control devices for gas burners and burning appliances
Special requirements pressure regulator
2020-11-19 released
2021-10-01 implementation
State Administration for Market Regulation
Issued by the National Standardization Management Committee
Table of contents
Foreword Ⅰ
1 Scope 1
2 Normative references 1
3 Terms and definitions 1
4 Classification and grouping 2
4.1 Voltage regulator classification 2
4.2 Voltage regulator group 3
5 Structure and materials 3
5.1 General requirements 3
5.2 Structure 3
5.3 Material 4
5.4 Connection 4
6 Requirements 5
6.1 General requirements 5
6.2 Component requirements 5
6.3 Performance requirements 5
7 Test method 7
7.1 Test conditions 7
7.2 Test sequence 7
7.3 Component test 7
7.4 Performance test 7
8 Inspection rules 10
8.1 Factory inspection 10
8.2 Type inspection 11
9 Signs, installation and operating instructions 12
9.1 Sign 12
9.2 Installation and operating instructions 12
9.3 Warning notice 13
10 Packaging, transportation and storage 13
Appendix A (informative appendix) The structural changes of this standard compared with ISO 23551-2.2018 14
Appendix B (informative appendix) Technical differences between this standard and ISO 23551-2.2018 and their reasons 15
Appendix C (informative appendix) Correspondence table 18 for clauses supporting the basic requirements of GB 16914-2012
Appendix D (informative appendix) Application of voltage regulator 19
Appendix E (informative appendix) Examples of typical voltage regulators and their parts 20
Appendix F (Normative Appendix) Regulator Function Requirements and Test Methods 21
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard uses the redrafting law to amend and adopt ISO 23551-2.2018 ``Gas burner and gas appliance safety and control device characteristics
Special requirements Part 2.Pressure regulating device.
Compared with ISO 23551-2.2018, this standard has many adjustments in structure. Appendix A lists this standard and ISO 23551-2.
2018 chapter number comparison list.
Compared with ISO 23551-2.2018, this standard has technical differences. The terms involved in these differences have been
The vertical single line (∣) in the white position is marked. Appendix B gives a list of the corresponding technical differences and their reasons.
This standard is consistent with GB 16914-2012 "Safety Technical Conditions for Gas Burning Appliances", and the support of this standard is given in Appendix C.
Support the clause correspondence table of GB 16914-2012 basic requirements.
This standard was proposed and managed by the Ministry of Housing and Urban-Rural Development of the People's Republic of China.
Drafting organizations of this standard. Guangzhou Jingding Electrical Technology Co., Ltd., North China Municipal Engineering Design and Research Institute Co., Ltd., Qingdao
Economic and Technological Development Zone Haier Water Heater Co., Ltd., Shanghai Feiao Gas Equipment Co., Ltd., Cite Gas Control System Manufacturing (Suzhou) Co., Ltd.
Company, Ito Future Energy Equipment (Shanghai) Co., Ltd., Guangdong Suzuki Intelligent Technology Co., Ltd., Shaoxing Eco Electric Co., Ltd., Ios
Mies (China) Water Heater Co., Ltd., Guangdong Wanhexin Electric Co., Ltd., Zhongshan Junye Jiaant Electric Co., Ltd., Guangdong Qiangji
Electrical Technology Co., Ltd., Shanghai Qiaoheng Industrial Co., Ltd., Zhejiang Sanguo Precision Electromechanical Co., Ltd., National Gas Appliance Quality Supervision and Inspection Center.
The main drafters of this standard. Pang Zhiyong, Pan Cuijing, Li Jian, Zhou Shijun, Ling Juan, Wang Xianglin, Yao Zhanpeng, Gu Wei, Qiu Bu, Jiang Xianming, Bai Yang,
Peng Yin, Bao Haiqiang, Li Pingyou, Yang Guoqiang, Zhang Mengting, Pang Bo.
Safety and control devices for gas burners and burning appliances
Special requirements pressure regulator
1 Scope
This standard specifies the classification and classification of burners and pressure regulating devices for burning appliances that use urban gas specified in GB/T 13611.
Group, structure and materials, requirements, test methods, inspection rules, signs, installation and operation instructions, packaging, transportation and storage.
This standard applies to the nominal size not greater than DN250 and the maximum inlet pressure not greater than 500kPa, which is used for gas water heaters and gas heating
The following pressure regulating devices for gas burning appliances or burning equipment such as water heaters, gas stoves, gas burners/machines, gas heaters, gas steam boxes, gas boilers.
---Self-operated pressure regulating device;
---Auxiliary energy can be used, and the auxiliary energy is only used to change the outlet pressure setting instead of the pressure regulating device of positive pressure, zero pressure and negative pressure in the control mode.
This standard does not apply to.
--- Pressure regulating devices installed outdoors and exposed to the environment;
---Gas/air ratio adjustment device/system.
2 Normative references
The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this document.
For undated references, the latest version (including all amendments) applies to this document.
GB/T 2423.10 Environmental Test Part 2.Test Method Test Fc. Vibration (Sine)
GB 2828.1 Sampling Inspection Procedures by Attributes Part 1.Batch Inspection Sampling Plan Retrieved by Acceptance Quality Limit (AQL)
GB 3836.4 Explosive atmosphere Part 4.Equipment protected by intrinsically safe "i"
GB/T 13611 Classification and basic characteristics of urban gas
GB/T 30597-2014 General requirements for safety and control devices for gas burners and burning appliances
3 Terms and definitions
The following terms and definitions defined in GB/T 30597 apply to this document.
3.1
Pressure regulator
Regulator
No matter where the inlet pressure and/or flow rate changes within a given range, the outlet pressure remains stable within a given range.
Note. See Appendix D for its application, and Appendix E for examples.
3.2
Adjustable voltage regulator
A pressure regulator that can change the set value of its outlet pressure.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 39493-2020_English be delivered?Answer: Upon your order, we will start to translate GB/T 39493-2020_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 39493-2020_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 39493-2020_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|