US$139.00 · In stock Delivery: <= 2 days. True-PDF full-copy in English will be manually translated and delivered via email. SN/T 2498.3-2011: Basic environmental testing procedure for the import and export fireworks. Test Z/AD: Composite temperature/humidity cyclic test Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| SN/T 2498.3-2011 | English | 139 |
Add to Cart
|
2 days [Need to translate]
|
Basic environmental testing procedure for the import and export fireworks. Test Z/AD: Composite temperature/humidity cyclic test
| Valid |
SN/T 2498.3-2011
|
PDF similar to SN/T 2498.3-2011
Basic data | Standard ID | SN/T 2498.3-2011 (SN/T2498.3-2011) | | Description (Translated English) | Basic environmental testing procedure for the import and export fireworks. Test Z/AD: Composite temperature/humidity cyclic test | | Sector / Industry | Commodity Inspection Standard (Recommended) | | Classification of Chinese Standard | Y88 | | Classification of International Standard | 74.100.30 | | Word Count Estimation | 5,566 | | Date of Issue | 2011-09-09 | | Date of Implementation | 2012-04-01 | | Quoted Standard | SN/T 0306.2; SN/T 0306.3; SN/T 0306.5-2012 | | Regulation (derived from) | National-Quality-Inspection-accreditation (2011) 492; Industry Standard Filing Announcement 2012 No.9 (Total No.153) | | Issuing agency(ies) | General Administration of Customs | | Summary | This standard specifies the import and export of fireworks products, environmental testing in the "temperature, humidity cyclic test, " the test method. This standard applies to the use of the accelerated method. Determine the import and export of fireworks products at high temperatures, suitability of use and storage of high humidity and low temperature conditions deteriorate. |
SN/T 2498.3-2011: Basic environmental testing procedure for the import and export fireworks. Test Z/AD: Composite temperature/humidity cyclic test ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Basic environmental testing procedure for the import and export fireworks.Test Z/AD. Composite temperature/humidity cyclic test
People's Republic of China Entry-Exit Inspection and Quarantine Standards
Importers Pyrotechnic products Basic environmental testing norms
Test Z/AD. temperature, humidity combined cycle test methods
TestZ/AD. Compositetemperature/humiditycyclictest
Issued on. 2011-09-09
2012-04-01 implementation
People's Republic of China
The State Administration of Quality Supervision, Inspection and Quarantine released
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
This standard is proposed and managed by the National Certification and Accreditation Administration Committee.
This standard was drafted. People's Republic of China Hunan Exit Inspection and Quarantine.
The main drafters of this standard. Jiang owned Cheng, Zhang Guanghui, Europe Yang, Tan Aixi, Xiaojia Yong, Jiang put Ming, Li Yue, Tan Xiaohua, Chen Cheng, Qiu Zhao tree.
Importers Pyrotechnic products Basic environmental testing norms
Test Z/AD. temperature, humidity combined cycle test methods
1 Scope
This standard specifies the import and export of fireworks products basic environmental tests "Temperature, humidity cyclic test" test method.
This standard applies to the use of the accelerated method to determine the import and export of fireworks products in high temperature, high humidity and low temperature reservoir conditions and deterioration
Keep applicability.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
SN/T 0306.2 export fireworks testing procedures - Part 2. Toy fireworks delivery inspection
SN/T 0306.3 inspection of export fireworks Part 3. Large fireworks delivery inspection
SN/T 0306.5-2012 inspection of export fireworks Part 5. Type tests
Test Method 3
3.1 Equipment
3.1.1 Temperature/humidity chamber. The temperature can be maintained at 75 ℃ ± 2 ℃, relative humidity can be maintained at 93% ± 2%.
3.1.2 cryostat tank. the temperature can be maintained at -50 ℃ ± 2 ℃.
3.1.3 Temperature/humidity automatic recording system. real-time measurement, recording and storage temperature/humidity test chamber temperature and humidity, and can record low
Warm incubator temperature.
NOTE. As a climatic chamber can meet the requirements of 3.1.1 and 3.1.2, you can only use the same climatic chamber.
3.2 Sample Requirements
Sample to be tested should be Pyrotechnic products, the number of samples is 6 or 6 sales package.
3.3 Test Procedure
3.3.1 Initial Detection
Three randomly selected samples of packing or three sales, according to SN/T 0306.5-2012 requirements of Appendix A, respectively appearance
Size, component mounting, fuse and discharge performance testing, if not any SN/T 0306.2 and SN/T 0306.3 provisions
Defects, the remaining three samples or three sales package for environmental testing.
3.3.2 Environmental Testing
3.3.2.1 The sample was kept at room temperature for 2h.
3.3.2.2 The sample was placed in a cryostat chamber temperature of -50 ℃, keeping 6h.
3.3.2.3 sample was removed from the cryostat chamber, kept at room temperature for 2h.
|