HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (26 Oct 2025)

SN/T 2446-2010 English PDF

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
SN/T 2446-2010English239 Add to Cart 3 days [Need to translate] Determination of dimethyl fumarate in leather and leather products. Gas chromatography-mass method Obsolete SN/T 2446-2010

PDF similar to SN/T 2446-2010


Standard similar to SN/T 2446-2010

QB/T 2709   QB/T 2706   QB/T 2464.23   SN/T 5322   SN/T 5319   SN/T 2449   

Basic data

Standard ID SN/T 2446-2010 (SN/T2446-2010)
Description (Translated English) Determination of dimethyl fumarate in leather and leather products. Gas chromatography-mass method
Sector / Industry Commodity Inspection Standard (Recommended)
Classification of Chinese Standard Y45
Classification of International Standard 59.140.01
Word Count Estimation 6,693
Date of Issue 2010-03-02
Date of Implementation 2010-09-16
Regulation (derived from) State inspection recognized (2010) 98; industry standard filing Notice 2010 No. 5 (No. 125 overall)
Issuing agency(ies) General Administration of Customs
Summary This standard specifies the leather and its products of dimethyl fumarate by gas chromatography/mass spectrometry. This standard applies to leather and its products Determination of dimethyl fumarate.

SN/T 2446-2010: Determination of dimethyl fumarate in leather and leather products. Gas chromatography-mass method


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Determination of dimethyl fumarate in leather and leather products.Gas chromatography-mass method Exit inspection and quarantine industry standard book People's Republic of China Determination of dimethyl fumarate in leather and leather products Gas Chromatography/Mass Spectrometry Issued on. 2010-03-02 2010-09-16 implementation People's Republic of China The State Administration of Quality Supervision, Inspection and Quarantine released

Foreword

Appendix A of this standard is an informative annex. This standard is proposed and managed by the National Certification and Accreditation Administration Committee. This standard by the People's Republic of China Guangdong SAIEC IQ drafting, People's Republic of China Fujian Exit Inspection and Quarantine, China PRC Shenzhen Entry-Exit Inspection and Quarantine of Jilin People's Republic of China participated in the drafting. The main drafters of this standard. Liu Yingfeng, Di Cuiping, Linbi Fen, ZHOU Ming-hui, Li Dan, Homocysteine on Zheng Jianguo, Zhang Zhihui, Yueda Lei, Xiaoda Hui, Li Bin, Jiang Xiaoli. This standard is the first release of the entry-exit inspection and quarantine industry standards. Determination of dimethyl fumarate in leather and leather products Gas Chromatography/Mass Spectrometry

1 Scope

This standard specifies the leather industry dimethyl fumarate by gas chromatography/mass spectrometry methods. This standard applies to leather and leather products - Determination of dimethyl fumarate.

2 principle of the method

With dehydrated ethyl acetate in a sample of dimethyl fumarate ultrasonic extraction, purification of the extract by gas chromatography/mass spectrometry Analyzer (GC/MS) and confirmed, external standard.

3 Reagents and materials

Unless otherwise stated, use only reagents of analytical grade or higher purity. 3.1 ethyl acetate.? 5 by molecular sieve dehydration process. 3.2 Dimethyl fumarate standards. purity ≥98%. 3.3 neutral alumina column. 6mL/1000mg.

4 instruments and equipment

4.1 Gas chromatography/mass spectrometry (GC/MSD). with EI source. 4.2 rotary evaporator. 4.3 stoppered cylinders. 5mL. 4.4 ultrasonic extractor. 4.5 Syringe. 2mL. 4.6 stoppered conical flask. 100mL. 4.7 micro-injector. 10μL. 4.8 round-bottomed flask. 100mL. 4.9 plug volumetric flask. 25mL. 4.10 Electronic balance. a sense of the amount of 0.1mg. Step 5 Analysis 5.1 Preparation and processing of samples Take a representative sample of about 5mm × 5mm cut into small pieces, mix, weigh about 5.0g from the mixed sample (accurate to 0.01g), set In stoppered Erlenmeyer flask (4.6) in. At least two parallel determination of the same sample. Add to 30mL by 5? Molecular sieve dehydration ethyl acetate (3.1), The flask was sealed, shake vigorously, all immersed in a liquid sample, (4.4) in the ultrasonic extraction 10min ultrasonic extractor will extract Decanted into a round bottom flask (4.8); then dehydrated 20mL ethyl acetate (3.1) Repeat the above steps once the combined extracts. In a rotary evaporator On (4.2) and concentrated to near 3mL, transferred to a stoppered graduated cylinder (4.3), rinsed with a small amount of ethyl acetate dehydration round-bottomed flask, lotion incorporated into the cylinder with a stopper (4.3), and finally with ethyl acetate dehydration volume to 5.0mL. (4.5) of 2mL test solution using a syringe through neutral alumina column (3.3) Net After technology, gas chromatography/mass spectrometry.


Refund Policy     Privacy Policy     Terms of Service     Shipping Policy     Contact Information