SN/T 2174-2008: Determination of flash point for dangerous goods of flammable liquids closed cup method
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
SN/T 2174-2008English169 Add to Cart 3 days [Need to translate] Determination of flash point for dangerous goods of flammable liquids closed cup method Valid SN/T 2174-2008

PDF similar to SN/T 2174-2008


Standard similar to SN/T 2174-2008

JJF 1070.2   GB 190   GB/T 191   SN/T 2170   SN/T 2171   SN/T 2169   

Basic data

Standard ID SN/T 2174-2008 (SN/T2174-2008)
Description (Translated English) Determination of flash point for dangerous goods of flammable liquids closed cup method
Sector / Industry Commodity Inspection Standard (Recommended)
Classification of Chinese Standard A80
Classification of International Standard 13.300
Word Count Estimation 6,673
Date of Issue 2008-09-04
Date of Implementation 2009-03-16
Quoted Standard GB 19458; United Nations "on the Recommendations on the Transport of Dangerous Goods. Model Regulations " (fourteenth revised edition); United Nations ' Recommendations on the Transport of Dangerous Goods book Manual of Tests and Criteria " (fourth revised edition)
Issuing agency(ies) General Administration of Customs
Summary This standard specifies the dangerous goods closed cup flash point of flammable liquids test equipment, test procedures and test results. This standard applies to flammable liquids of dangerous goods carried Closed Cup Test.

SN/T 2174-2008: Determination of flash point for dangerous goods of flammable liquids closed cup method


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Determination of flash point for dangerous goods of flammable liquids closed cup method Exit inspection and quarantine industry standard book People's Republic of China Dangerous flammable liquids Closed Cup Test Method Posted 2008-09-04 2009-03-16 implementation People's Republic of China The State Administration of Quality Supervision, Inspection and Quarantine released

Foreword

This revised standard adopts the United Nations "on the Recommendations on the Transport of Dangerous Goods Model Regulations ·" (fourteenth revised edition) and "test and standard Associate Handbook "(fourth revised edition). This standard was proposed by the State Administration of Quality Supervision Inspection and Quarantine of People's Republic of China. This standard by the National Certification and Accreditation Administration Committee. This standard is drafted by. People's Republic of China Tianjin Exit Inspection and Quarantine. Participated in the drafting of this standard. the Chemical Institute of Standardization, Jiangnan University, Tianjin Academy of Inspection and Quarantine Science and Technology. The main drafters of this standard. Lining Tao, in Yanjun, Zhao Lihua, Li Xue Yang, Zhao Qing, Li Jing. This standard is the first release of the entry-exit inspection and quarantine industry standards. Dangerous flammable liquids Closed Cup Test Method

1 Scope

This standard specifies the dangerous flammable liquids closed cup flash point test test equipment, test procedures and test results. This standard applies to the determination of closed cup flash point tester dangerous flammable liquid.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references. All subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB 19458 safety inspection of hazardous properties of dangerous goods - General specifications United Nations "on the Recommendations on the Transport of Dangerous Goods Model Regulations ·" (fourteenth revised edition) United Nations "on the Recommendations on the Transport of Dangerous Goods, Tests and Criteria Handbook" (fourth revised edition)

3 Terms and Definitions

United Nations "on the Recommendations on the Transport of Dangerous Goods Model Regulations ·" (fourteenth revised edition), "on the Recommendations on the Transport of Dangerous Goods * Manual of Tests and Criteria "(fourth revised edition), GB 19458 and established the following terms and definitions apply to this standard. 3.1 Flammable liquids, liquid mixtures or liquids containing solids, including but not because of its hazardous properties have been included in other categories of liquid, Flash point, closed cup test flash point equal to or lower than 60 ℃. 3.2 Sample under prescribed conditions is heated to its mixture of vapor and air contacts the minimum temperature of the flame when the flash fire occurred.

4 Instrument

4.1 Closed Cup Tester. 4.2 Thermometer (accuracy of 0.1 ℃).

5 test procedure

5.1 The sample was carefully injected into the closed cup tester, start heating. Upon heating, the following should be noted. A) The test sample flash point below 50 ℃ from start to finish to the test constantly stirring and sample temperature liters per minute High 2 ℃ ~ 3 ℃; B) When the test sample is higher than the flash point of 50 ℃, heating rate began to rise evenly, stirring regularly. Before the expected flash point 40 ℃, adjust the heating rate, so that when the expected flash point 20 ℃ before the heating rate per minute at elevated control 2 ℃ ~ 3 ℃, and We should constantly stirring. 5.2 Sample temperature reaches 10 ℃ before the expected flash point, ignition test for each sample by the flash point of less than 104 ℃ 1 ℃; For flash point The sample is higher than 104 ℃ ignition test each by 2 ℃. During this period, it should continue stirring; stirring was stopped only when the ignition. ignition When the flame in the space containing the vapor 0.5s down on the cup, 1s residence immediately back into place in this position. If you do not see the flash fire, Continue stirring the sample, as required under this section is repeated test firings.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of SN/T 2174-2008_English be delivered?

Answer: Upon your order, we will start to translate SN/T 2174-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of SN/T 2174-2008_English with my colleagues?

Answer: Yes. The purchased PDF of SN/T 2174-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Refund Policy     Privacy Policy     Terms of Service     Shipping Policy     Contact Information