JJG 1145-2017: Medical X-ray Radiation Sources for Mammographic Equipment
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJG 1145-2017English419 Add to Cart 4 days [Need to translate] Medical X-ray Radiation Sources for Mammographic Equipment Valid JJG 1145-2017

PDF similar to JJG 1145-2017


Standard similar to JJG 1145-2017

GB/T 3222.1   JJG 188   JJF 1396   JJF 2017   JJF 1928   JJF 1927   

Basic data

Standard ID JJG 1145-2017 (JJG1145-2017)
Description (Translated English) Medical X-ray Radiation Sources for Mammographic Equipment
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A58
Classification of International Standard 17.240
Word Count Estimation 18,10
Date of Issue 2017-11-20
Date of Implementation 2018-02-20
Quoted Standard JJF 1001; JJF 1035; WS 522-2017; IEC 61223-3-2-2007; HEALTH & CONSUMER PROTECTION DIRECTORATE-GENERAL-2006; IAEA HUMAN HEALTH REPORTS NO.4-2011
Regulation (derived from) AQSIQ Notice 2017 No. 103
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine
Summary This standard applies to the first verification, follow-up verification and in-use inspection of medical mammography X-ray sources. It includes medical digital mammographic X-ray sources and medical non-digital mammographic X-ray sources. Does not apply to medical mammography digital tomography X-ray radiation source.

JJG 1145-2017: Medical X-ray Radiation Sources for Mammographic Equipment

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Medical mammography testing procedures) National metrological verification regulations of the People's Republic of China Medical breast X-ray source Published on.2017-11-20 2018-02-20 Implementation The State Administration of Quality Supervision, Inspection and Quarantine issued Medical breast X-ray source Verification procedure Equipment Key units. National Ionizing Radiation Measurement Technical Committee The main drafting units. Beijing Institute of Metrology and Detection Hebei Zhongmo Medical Equipment Technology Co., Ltd. Chinese Academy of Medical Sciences Tumor Hospital Philips (China) Investment Co., Ltd. Participated in the drafting. Xiamen Metrology and Testing Institute Hebei Province Measurement Supervision and Inspection Institute This procedure entrusts the National Ionizing Radiation Measurement Technical Committee to explain The main drafters of this regulation. Guo Hongtao (Beijing Institute of Metrology and Detection) Sun Chaoyang (Hebei Zhongmo Medical Equipment Technology Co., Ltd.) Song Junfeng (Chinese Academy of Medical Sciences Cancer Hospital) Sun Jianhua [Philips (China) Investment Co., Ltd.] Participating drafters. Wang Huanning (Beijing Institute of Metrology and Detection) Liu Pingping (Xiamen Metrology and Measurement Institute) Cai Zonglin (Hebei Provincial Metrological Supervision and Inspection Institute)

table of Contents

Introduction (II) 1 Scope (1) 2 References (1) 3 Terms and units of measure (1) 3.1 Terms (1) 3.2 Units of measurement (1) 4 Overview (1) 5 Metrological performance requirements (2) 5.1 Average breast gland dose (2) 5.2 Resolution (2) 5.3 Radiation output (2) 5.4 X-ray tube voltage (2) 6 General technical requirements (2) 7 Measuring Instruments Control (2) 7.1 Verification conditions (2) 7.2 Verification Projects (3) 7.3 Verification Methods (3) 7.4 Processing of verification results (7) 7.5 Certification Period (8) Appendix A Verification Certificate and Notification of Verification Results (Inner Page) Recommended Format (9) Appendix B Testimonial Original Record Recommended Format (10) Appendix C Various Breast X-Ray Targets/Filters (11) Appendix D Dose Performance Modal Technical Requirements (12) Appendix E Resolving Modal Technical Requirements (13)

Introduction

This regulation was prepared in accordance with the requirements of JJF1002-2010 "Rules for the preparation of national metrological verification regulations." JJF1001- 2011 Common Measurement Terms and Definitions and JJF1059.1-2012 Measurement Uncertainty Evaluation and Expression To support the establishment of this regulation and the preparation of the basis. This regulation is issued for the first time. Medical breast X-ray radiation source verification procedures

1 Scope

This procedure is applicable to the first verification, subsequent verification and in-use inspection of medical breast X-ray radiation sources. Its package Including medical digital breast X-ray sources and medical non-digital mammography sources. Does not apply to medical breast numbers Font layer synthetic photography X-ray radiation source.

2 references

This procedure refers to the following documents. JJF1001 Universal Measurement Terms and Definitions JJF1035 Ionizing Radiation Measurement Terms and Definitions WS522-2017 Mammography Digital Radiography System Quality Control Inspection Specification IEC 61223-3-2.2007 Evaluation and routine testing of medical imaging departments - Part 3-2. Acceptance tests Mammography X-ray imaging performance (Evaluation and routine testing in medical imaging Departments Part 3-2.Acceptancetests-ImagingperformanceofmammographicX-ray Equipment Health Quality Assurance Guide (Europeanguidelinesforqualityassuranceinbreastcancerscreeningand Diagnosis) IAEAHumanHealthReportsNo.4-2011 Implementation of International Standards for Diagnostic Radiation Dosimetry (TRS) 457). Evaluation of Measurement Results[Implementation of the International Code of Practice on Dosimetryin DiagnosticRadiology(TRS457).ReviewofTestResults] For dated references, only the dated version applies to this procedure; any undated references The latest version (including all amendments) is applicable to this procedure.

3 Terms and units of measure

3.1 Terms The terms and definitions defined by JJF1001, JJF1035, and the following apply to this procedure. 3.1.1 Mammary gland average dose averagelandlanddose, AGD Subjects in mammography were subjected to uniform compression of the breast's glandular tissue (excluding skin and fat) The average absorbed dose of tissues). 3.2 Units of measurement Absorbed dose, the unit name is Ge, and the unit symbol is Gy.

4 Overview

Medical breast X-ray source is mainly composed of X-ray source assembly, high voltage generator, imaging device, image processing

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJG 1145-2017_English be delivered?

Answer: Upon your order, we will start to translate JJG 1145-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJG 1145-2017_English with my colleagues?

Answer: Yes. The purchased PDF of JJG 1145-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.