US$549.00 · In stock Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1927-2021: Calibration Specification for Phantoms Used in Computed Radiography (CR) and Digital Radiography (DR) Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJF 1927-2021 | English | 549 |
Add to Cart
|
5 days [Need to translate]
|
Calibration Specification for Phantoms Used in Computed Radiography (CR) and Digital Radiography (DR)
| Valid |
JJF 1927-2021
|
PDF similar to JJF 1927-2021
Basic data Standard ID | JJF 1927-2021 (JJF1927-2021) | Description (Translated English) | Calibration Specification for Phantoms Used in Computed Radiography (CR) and Digital Radiography (DR) | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A58 | Word Count Estimation | 25,268 | Issuing agency(ies) | State Administration for Market Regulation |
JJF 1927-2021: Calibration Specification for Phantoms Used in Computed Radiography (CR) and Digital Radiography (DR) ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Medical CD/DR performance phantom reproduction)
National Metrology Technical Specification of the People's Republic of China
Specification for calibration of medical CR/DR performance phantoms
Published on 2021-10-18
2022-04-18 Implementation
Released by the State Administration for Market Regulation
Medical CR/DR Performance Phantom
Calibration specification
Focal Point. National Technical Committee for Measurement of Ionizing Radiation
Main drafting unit. China Institute of Testing Technology
Zunyi City Product Quality Inspection and Testing Institute
Participating in the drafting unit. China Institute of Metrology
Chongqing Institute of Metrology and Quality Inspection
Yibin Metrology and Testing Institute
This specification is entrusted to the National Ionizing Radiation Measurement Technical Committee to be responsible for the interpretation
The main drafters of this specification.
Fan Jie (China Institute of Testing Technology)
Zhang Conghua (China Institute of Testing Technology)
Chen Fengjuan (Zunyi City Product Quality Inspection and Testing Institute)
Lin Tao (China Institute of Testing Technology)
Participating drafters.
Li Xingdong (China Institute of Metrology)
Song Hailong (Chongqing Institute of Metrology and Quality Inspection)
Wang Kun (Yibin Metrology and Testing Institute)
content
Introduction (Ⅱ)
1 Scope(1)
2 References (1)
3 Terms and units of measurement(1)
4 Overview(1)
5 Metrology Characteristics(2)
5.1 Low contrast(2)
5.2 Attenuator Thickness(2)
5.3 Uniformity (2)
5.4 Test card identification error (2)
5.5 Line pair identification error(2)
6 Calibration Conditions(2)
6.1 Environmental conditions (2)
6.2 Measurement standards and other equipment(2)
7 Calibration items and calibration methods (3)
7.1 Low contrast(3)
7.2 Attenuator thickness(4)
7.3 Uniformity(4)
7.4 Test card identification error(4)
7.5 Pair identification error(5)
8 Expression of calibration results (5)
9 Recalibration interval(5)
Appendix A Calibration Original Record (Recommended) Format Style (6)
Appendix B Calibration Certificate Inner Page (Recommended) Format (9)
Appendix C Measurement Uncertainty Evaluation Example(10)
Appendix D Standard Test Specimen (19)
Introduction
This specification is based on JJF 1071-2010 "Rules for Compilation of National Metrology Calibration Specifications", JJF 1001-2011 "General
Compiled with Measurement Terms and Definitions", JJF 1059.1-2012 "Measurement Uncertainty Evaluation and Representation".
According to the actual situation of medical CR/DR performance phantom, the formulation of this calibration specification refers to JJG1078-2012
"Medical Digital Photography (CR, DR) System X-ray Radiation Source Verification Regulations", WS76-2020 "Medical X-ray
Diagnostic Equipment Quality Control Testing Specification.
This specification is published for the first time.
Specification for calibration of medical CR/DR performance phantoms
1 Scope
This specification is applicable to medical CR/DR performance phantoms and multifunctional phantoms for medical CR/DR performance testing.
The Quantitative section relates to the calibration of the module.
2 Reference documents
This specification references the following documents.
JJF 1035 Ionizing Radiation Measurement Terms and Definitions
JJG1078 Medical digital photography (CR, DR) system X-ray radiation source
GB/T 23903 Radiographic Image Resolution Tester
WS76-2020 Specification for quality control testing of medical X-ray diagnostic equipment
For dated references, only the dated version applies to this specification; for undated references
The latest version (including all amendments) applies to this specification.
3 Terminology and units of measurement
The terms and definitions defined in JJF 1035, JJG1078, GB/T 23903 and the following apply to this specification.
3.1 Terminology
The minimum contrast of a specified shape and area that can be distinguished from a uniform low-density background, expressed as a percentage.
3.1.2 Uniformity
The difference in the equivalent thickness of the phantom due to the phantom material and along the thickness difference, usually expressed as a percentage.
3.1.3 Line pair density densityoflinepair
The total number of wire pairs per unit length in the wire pair width direction, in LP/mm.
3.2 Units of measurement
Unit name of phantom geometric length. mm; symbol. mm.
4 Overview
The medical CR/DR performance phantom (hereinafter referred to as the phantom) is a systematic system for medical digital photography (CR, DR).
device that can be detected. It has holes (or protrusions), rulers, uniform areas, etc. of a specific depth, which are used to detect medical data.
Measurement of low-contrast resolution, spatial resolution, and consistency of light field and radiation field of digital photography (CR, DR) systems
parameter. The phantom is generally composed of a low-contrast resolution module, a spatial resolution test plug-in, and a radiation field and light field consistency check.
It consists of test card and uniformity test plug-in.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1927-2021_English be delivered?Answer: Upon your order, we will start to translate JJF 1927-2021_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJF 1927-2021_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1927-2021_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|