Calibration Specification for Beam Quality Inspection Instruments of Radiation Therapy
| Valid |
JJF 1928-2021
|
PDF similar to JJF 1928-2021
Basic data Standard ID | JJF 1928-2021 (JJF1928-2021) | Description (Translated English) | Calibration Specification for Beam Quality Inspection Instruments of Radiation Therapy | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A58 | Word Count Estimation | 17,113 | Issuing agency(ies) | State Administration for Market Regulation |
JJF 1928-2021: Calibration Specification for Beam Quality Inspection Instruments of Radiation Therapy ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Appearance of Radiotherapy Beam Inspection Apparatus)
National Metrology Technical Specification of the People's Republic of China
Radiotherapy beam quality checker
Calibration specification
Published on 2021-10-18
2022-04-18 Implementation
Released by the State Administration for Market Regulation
Radiotherapy beam quality checker
Calibration specification
Focal Point. National Technical Committee for Measurement of Ionizing Radiation
Main drafting unit. China Institute of Testing Technology
Sichuan Cancer Hospital
Guangxi Zhuang Autonomous Region Metrology and Testing Research Institute
Participating in the drafting unit. Dalian Metrology, Inspection and Testing Research Institute Co., Ltd.
Anyang Quality and Technical Supervision, Inspection and Testing Center
This specification is entrusted to the National Ionizing Radiation Measurement Technical Committee to be responsible for the interpretation
The main drafters of this specification.
Gong Lan (China Institute of Testing Technology)
Kang Shengwei (Sichuan Cancer Hospital)
Chen Shengbiao (Guangxi Zhuang Autonomous Region Metrology and Testing Research Institute)
Participating drafters.
Shi Ming (Dalian Metrology, Inspection and Testing Research Institute Co., Ltd.)
Zhou Yuanyuan (China Institute of Testing Technology)
Zhang Hui (Anyang Quality and Technical Supervision, Inspection and Testing Center)
Liu Cao (China Institute of Testing Technology)
content
Introduction (Ⅱ)
1 Scope(1)
2 References (1)
3 Terms and units of measurement(1)
4 Overview(1)
5 Metrology Characteristics(2)
5.1 Calibration factor(2)
5.2 Repeatability(2)
5.3 Indication nonlinearity (2)
6 Calibration Conditions(2)
6.1 Environmental conditions (2)
6.2 Measurement standards and other equipment(2)
7 Calibration items and calibration methods (2)
7.1 Calibration factor(2)
7.2 Repeatability(3)
7.3 Indication nonlinearity (3)
8 Expression of calibration results (4)
9 Recalibration interval(4)
Appendix A Calibration Original Record (Recommended) Format Style (5)
Appendix B Calibration Certificate Inner Page (Recommended) Format (7)
Appendix C Example of Uncertainty Assessment of Dose Calibration Factor(8)
Introduction
JJF 1071-2010 "Rules for the Compilation of National Metrology Calibration Standards", JJF 1001-2011 "General Metrology Terms and
Definition" and JJF 1059.1-2012 "Measurement Uncertainty Evaluation and Representation" together constitute support for the formulation of this specification
The basic series of specifications. In the formulation of this specification, reference is made to JJG589-2008 "Medical Electron Accelerator Radiation Sources",
JJG912-2010 "Therapeutic Level Ionization Chamber Dosimeter", JJG2044-2019 "Gamma-ray air kerma measurement
Apparatus Verification System Table", GB 15213-2016 "Medical Electron Accelerator Performance and Test Methods",
Basic requirements and methods for documents such as IEC 60976.2007 Performance of Medical Electron Accelerators for Medical Electrical Equipment.
This specification is published for the first time.
Radiotherapy beam quality checker
Calibration specification
1 Scope
This specification applies to the beam quality inspection of 60Co gamma rays, accelerator X-rays and electron rays used in radiotherapy
It is not suitable for 2D and 3D dosimetry systems for verification of radiation treatment plans.
2 Reference documents
This specification references the following documents.
JJG589 Medical electron accelerator radiation source
JJG912 Therapeutic level ionization chamber dosimeter
JJF 1035 Ionizing Radiation Measurement Terms and Definitions
GB 15213 Medical Electron Accelerator Performance and Test Methods
GB/T 19046 Procedures for acceptance test and periodic inspection of medical electron accelerators
For dated references, only the dated version applies to this specification; for undated references
The latest version (including all amendments) applies to this specification.
3 Terminology and units of measurement
3.1 Terminology
The terms and definitions defined in JJF 1001, JJF 1035, GB 15213 and the following apply to this specification.
Along the ray axis, the distance from the radiation source surface to the irradiated surface, also known as the source skin distance.
3.1.2 Irradiation field fieldofbeam
The irradiation surface of a radiation beam in a plane perpendicular to its axis.
For X-radiation, it is the distance measured from the front surface of the target along the axis of the radiation beam to the isocenter; for non-isocentric equipment, then
is the distance to the specified plane.
Electron beam radiation is the distance measured from the electron radiation window along the beam axis to the end of the beam limiter or to a specified plane.
3.2 Units of measurement
Absorbed dose unit name. Gray [Ray]; Symbol. Gy.
4 Overview
Radiotherapy beam quality checker (hereinafter referred to as checker), mainly composed of ionizing radiation detector, signal processing
Unit, data acquisition unit, data analysis software, etc., used for electron linear accelerator or cobalt therapy machine in the development of
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1928-2021_English be delivered?Answer: Upon your order, we will start to translate JJF 1928-2021_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJF 1928-2021_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1928-2021_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|