HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189760 (18 Jan 2025)

JJF 1396-2013 PDF English


Search result: JJF 1396-2013_English: PDF (JJF1396-2013)
Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
JJF 1396-2013English160 Add to Cart 0-9 seconds. Auto-delivery. Calibration Specification for Spectrum Analyzer Valid
BUY with any currencies (Euro, JPY, GBP, KRW etc.): JJF 1396-2013     Related standards: JJF 1396-2013

PDF Preview: JJF 1396-2013


JJF 1396-2013: PDF in English

JJF 1396-2013 JJF NATIONAL METEOROLOGY TECHNICAL SPECIFICATION OF THE PEOPLE’S REPUBLIC OF CHINA Calibration specification for spectrum analyzer ISSUED ON. FEBRUARY 16, 2013 IMPLEMENTED ON. AUGUST 16, 2013 Issued by. General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China Table of contents Introduction ... 6  1 Scope ... 7  2 Normative references ... 7  3 Overview ... 7  4 Metrological characteristics ... 7  4.1 Reference frequency ... 7  4.2 Calibration signal level ... 7  4.3 Frequency marker ... 8  4.4 Sweep width ... 8  4.5 Resolution bandwidth ... 8  4.6 Frequency stability ... 8  4.7 Vertical display scale ... 8  4.8 Reference level ... 9  4.9 Input attenuator conversion effects ... 9  4.10 Resolution bandwidth conversion effect ... 9  4.11 Display average noise level... 9  4.12 Residual response ... 9  4.13 Image response ... 9  4.14 Scan time ... 9  4.15 Absolute amplitude ... 9  4.16 Input frequency response ... 10  4.17 Second harmonic distortion ... 10  4.18 Third-order intermodulation distortion... 10  4.19 Gain compression ... 10  4.20 Input voltage standing wave ratio... 10  4.21 Power bandwidth ... 10  5 Calibration conditions ... 10  5.1 Environmental conditions ... 10  5.2 Equipment used for calibration ... 11  6 Calibration items and calibration methods ... 12  6.1 Appearance and operation normality inspection ... 13  6.2 Reference frequency ... 13  6.3 Calibration signal level ... 14  6.4 Frequency reading ... 16  6.5 Sweep width ... 16  6.6 Resolution bandwidth ... 17  6.7 Noise sideband ... 20  6.8 Residual frequency modulation ... 21  6.9 Vertical display scale ... 22  6.10 Reference level ... 24  6.11 Input attenuator conversion effect ... 24  6.12 Resolution bandwidth conversion effect ... 25  6.13 Display average noise level ... 26  6.14 Residual response ... 27  6.15 Image response ... 27  6.16 Scan time ... 28  6.17 Absolute amplitude ... 29  6.18 Input frequency response ... 30  6.19 Second harmonic distortion ... 31  6.20 Third-order intermodulation distortion... 32  6.21 Gain compression ... 33  6.22 Input voltage standing wave ratio... 34  6.23 Frequency counting ... 34  6.24 Power bandwidth ... 35  7 Presentation of calibration results ... 35  8 Recalibration Interval ... 36  Appendix A Calibration record form ... 37  Appendix B The inner page format of calibration certificate ... 47  Appendix C Examples of measurement uncertainty evaluation ... 59  Calibration specification for spectrum analyzer 1 Scope This specification applies to the calibration of a spectrum analyzer in the frequency range from 3 Hz ~ 50 GHz. 2 Normative references This specification refers to the following documents. JJF 1071-2010 The rules for drafting national calibration specification For the dated documents, only the versions with the dates indicated are applicable to this specification; for the undated documents, only the latest version (including all the amendments) are applicable to this specification. 3 Overview Spectrum analyzer is a super-heterodyne receiver with display device. It consists of preselector, scanning local oscillator, mixer, middle amplifier, filter, detector, amplifier and display. It is mainly used for spectrum analysis, AND can also be used for the measurement of frequency, level, gain, attenuation, analog modulation and digital modulation, and distortion jitter, which is and indispensable instrument in communication, radio, television, radar, aerospace, and other technology areas. 4 Metrological characteristics 4.1 Reference frequency Frequency nominal value. 10 MHz; Frequency accuracy. 1 × 10-5 ~ 1 × 10-10. 4.2 Calibration signal level Level range. -30 dBm ~ 0 dBm; 4.16 Input frequency response Frequency range. 3 Hz ~ 50 GHz; Frequency response. ± 0.2 dB ~ ± 5 dB. 4.17 Second harmonic distortion Frequency range. 10 MHz ~ 25 GHz. 4.18 Third-order intermodulation distortion Frequency range. 10 MHz ~ 50 GHz. 4.19 Gain compression Frequency range. 10 MHz ~ 50 GHz. 4.20 Input voltage standing wave ratio Frequency range. 10 MHz ~ 50 GHz; Input voltage standing wave ratio. 1.02 ~ 3. 4.21 Power bandwidth 3dB bandwidth range. 1 Hz ~ 10 MHz; The maximum allowable error. ± 0.02 dB ~ ± 0.50 dB. Note. The above lists the measurement range and technical parameter requirements of each calibration parameter of the spectrum analyzer; during calibration, it shall follow the technical parameter requirements as ... ......
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.