JJG 1026-2007English799 Add to Cart 4 days [Need to translate] Verification Regulation of Medical Diagnostic X-ray Radiation Source for Spiral Computed Tomography(CT) Obsolete JJG 1026-2007
JJG 1026-1991EnglishRFQ ASK 3 days [Need to translate] Absorbed Dose Determination in Photon and Electron Beams Obsolete JJG 1026-1991

PDF similar to JJG 1026-2007


Standard similar to JJG 1026-2007

GB/T 3222.1   JJG 188   JJF 1396   JJF 2017   JJF 1928   JJF 1927   

Basic data

Standard ID JJG 1026-2007 (JJG1026-2007)
Description (Translated English) Verification Regulation of Medical Diagnostic X-ray Radiation Source for Spiral Computed Tomography(CT)
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A58;C43
Classification of International Standard 11.040.50
Word Count Estimation 20,271
Date of Issue 2007-08-02
Date of Implementation 2007-11-02
Quoted Standard GB 3100-1993; GB 3101-1993; GB 3102-1993; GB/T 17006-1997; GB/T 10149-1988; GB/T 17589-1998; GB 9706.18-2000; IEC 61223-3-5; IEC 60601 -2-44; IEC 61223-2-6
Regulation (derived from) AQSIQ Announcement No. 142 of 2007
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine
Summary This standard applies to new installations, the use and impact of the imaging properties of the parts after repair of medical diagnostic devices spiral computed radiography (CT) X-ray radiation source verification.

JJG 1026-2007: Verification Regulation of Medical Diagnostic X-ray Radiation Source for Spiral Computed Tomography(CT)


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Verification Regulation of Medical Diagnostic X-ray Radiation Source for Spiral Computed Tomography (CT) State verification procedures People's Republic of China Medical Diagnostic spiral computed tomography apparatus (CT) X-ray radiation source ComputedTomography (CT) Posted 2007-08-02 2007-11-02 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Medical Diagnostic spiral computed tomography apparatus (CT) X-ray radiation source verification procedures ComputedTomography (CT The regulations by the State Administration of Quality Supervision, Inspection and Quarantine approved on August 2, 2007, and from From November 2, 2007 implementation. Focal point. the National Technical Committee of ionizing radiation metrology Drafting. Beijing Institute of Metrology detection Xuanwu Hospital Participating units. Beijing Siemens Technology Development Co., Ltd. Three wide-cum-medical Toshiba Medical This procedure commissioned the National Technical Committee is responsible for ionizing radiation measurement interpretation The main drafters of this procedure. Tao (Beijing Institute of Metrology detection) Pengming Chen (Xuanwu Hospital) Drafters participate. Liang Shaohua (Beijing Siemens Technology Development Co., Ltd.) Liu Yong (three wide-cum-medical Toshiba Medical) Zhang Ying (Beijing Institute of Metrology detection) Bai Mei (Institute of Hospital Management Clinical Engineering Technology Research heart) Pengyong Lun (Beijing Institute of Metrology detection)

table of Contents

1 Scope (1) 2. Referenced Documents (1) 3 terminology and units of measurement (1) 3.1 The term (1) 3.2 units of measurement (3) 4 Overview (4) 5 metering performance requirements (4) 5.1 dose index (4) Uniformity 5.2 (4) Noise level 5.3 (4) 5.4 Consistency between images (5) 5.5 CT value (5) 5.6 thickness (5) 5.7 Spatial resolution (rate) (5) 5.8 low contrast resolution (rate) (5) 6 General technical conditions (6) 7 control of measuring instruments (6) 7.1 test conditions (6) 7.2 test items and test methods (6) 7.3 test results processing (10) 7.4 test cycle (10) A medical diagnostic device spiral computed tomography (CT) X-ray radiation test records appendix (11) Appendix B test certificate-page format (12) Appendix C helical scan tomographic slice thickness (13) Appendix D schematic detector spiral CT phantom (14) Medical Diagnostic spiral computed tomography apparatus (CT) X-ray radiation source verification procedures

1 Scope

The test procedures for new installations, the use and impact of the imaging properties of the parts repaired medical diagnostic spiral meter Computer imaging means (CT) X-ray radiation source verification.

2 Citations

The regulations cited in the following documents. [1] GB 3100 ~ 3102-1993 "Quantities and units" [2] GB/T 17006-1997 "evaluation in medical imaging departments and routine testing - Part 2-6. X-ray meter Operator body tomography equipment Stability Test " [3] GB/T 10149-1988 "X-ray equipment for medical terminology and symbols." [4] GB/T 17589-1998 "X-ray computed tomography apparatus Image quality assurance test specification" [5] GB 9706.18-2000 "Medical electrical equipment Part. X-ray computed tomography apparatus security Full-specific requirements " [6] IEC 61223-3-5EvaluationandRoutineTestingin MedicalImagingDepart- ments-Part 3-5. Acceptancetests --- ImagingPerformanceofComputedTomography X- rayequipment [7] IEC 60601-2-44 Medical Electrical Equipment --- Part 2-44. Particular RequirementsfortheSafetyofX-rayEquipmentforComputedTomography [8] IEC 61223-2-6Ed.2 --- CDV EvaluationandRoutineTestingin Medical ImagingDepartmentsPart 2-6Ed.2. ConstancyTests-ImagingPerformanceofComputed TomographyX-rayEquipment [9] Europeanguidelinesonqualitycriteriaforcomputedtomography2002-7-27 When using this procedure, it should pay attention to using the currently valid version of the documents cited.

3 terminology and units of measurement

3.1 Terms 3.1.1 Dose Index doseindex 3.1.1.1 CT dose index 100 (CTDI100) To produce a single axial scan along a line perpendicular to the plane layer dose distribution from -50mm to 50mm of Points divided by the number of slices N layer and a layer of nominal slice thickness T of the product. CTDI100 = ∫ 50mm -50mm D (z) N · Tdz (1) Where. D (z) --- along a line perpendicular to the plane dose layer distribution of the z-axis (z = 0 in the center), this sub-dose