JJF 1459-2014 English PDF

US$349.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJF 1459-2014: Calibration Specification for Exposure Coulometers Used in Medical Diagnostic X-ray Radiation Sources
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJF 1459-2014English349 Add to Cart 3 days [Need to translate] Calibration Specification for Exposure Coulometers Used in Medical Diagnostic X-ray Radiation Sources Valid JJF 1459-2014

PDF similar to JJF 1459-2014


Standard similar to JJF 1459-2014

GB/T 3222.1   JJG 188   JJF 1396   JJF 2017   JJF 1928   JJF 1927   

Basic data

Standard ID JJF 1459-2014 (JJF1459-2014)
Description (Translated English) Calibration Specification for Exposure Coulometers Used in Medical Diagnostic X-ray Radiation Sources
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A58
Classification of International Standard 17.240
Word Count Estimation 15,143
Date of Issue 4/21/2014
Date of Implementation 7/21/2014
Quoted Standard JJG 744-2004; JJF 1001-2011; JJF 1035-2006
Regulation (derived from) The State Administration of Quality Supervision, Inspection and Quarantine Notice No. 47 of 2014
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine
Summary This Standard specifies the medical diagnostic X-ray tube the amount of charge (mAs) meter calibration, including intervention and inductive meter. This Standard does not apply to an inductive ammeter (clamp meter) calibration.

JJF 1459-2014: Calibration Specification for Exposure Coulometers Used in Medical Diagnostic X-ray Radiation Sources


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification for Exposure Coulometers Used in Medical Diagnostic X-ray Radiation Sources People's Republic of China National Metrology Technical Specifications Medical Diagnostic X-ray tube charge amount (mAs) count Calibration Specification Issued on. 2014-04-21 2014-07-21 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Medical Diagnostic X-ray tube charge amount (mAs) count Calibration Specification X-ray Focal point. the National Technical Committee of ionizing radiation metrology Drafting. Shanghai Institute of Measurement and Testing This specification commissioned the National Technical Committee is responsible for ionizing radiation measurement interpretation The main drafters of this specification. Teng Jing Jing (Shanghai Institute of Measurement and Testing) Snow (Shanghai Institute of Measurement and Testing) Dong Lin (Shanghai Institute of Measurement and Testing) Drafters participate. Chen Jianxin (Shanghai Institute of Measurement and Testing) Xu Kai (Shanghai Institute of Measurement and Testing)

table of Contents

Introduction (Ⅱ) 1 Scope (1) 2. References (1) 3 terminology and units of measurement (1) 3.1 The term (1) 3.2 units of measurement (1) 4 Overview (2) 5 Metrological characteristics (2) 5.1 intrinsic error (2) 5.2 nonlinear (2) 5.3 Repeatability (2) Calibration Condition 6 (2) 6.1 environmental conditions (2) 6.2 measurement standards (2) 7 calibration items and calibration methods (3) Intrinsic error 7.1 (3) 7.2 Nonlinear (3) 7.3 Repeatability (3) 8 calibration results expression (3) 9 Recalibration interval (4) Appendix A calibration record format (5) Appendix B Calibration Certificate-page content and format (6) Appendix C measurement error inherent Evaluation of Uncertainty Example (7)

Introduction

This specification tube charge amount measurement range in part by reference JJG744-2004 "Medical Diagnostic X-ray radiation" Comprehensive reference to its metrological characteristics typical indicators of various manufacturers. This specification is the first release. Medical Diagnostic X-ray tube charge amount (mAs) count Calibration Specification

1 Scope

This instruction applies to diagnostic X-ray tube charge amount (mAs) meter calibration, including intervention and inductive meter. This specification does not apply to inductive ammeter (clamp meter) calibration. 2. References This specification refers to the following documents. JJG744-2004 diagnostic X-ray radiation JJF 1001-2011 common measurement terms and definitions JJF 1035-2006 ionizing radiation measurement terms and definitions For dated references, only the dated edition applies to this specification; undated reference documents Member, the latest edition (including any amendments) applies to this specification.

3 terminology and units of measurement

The above-cited documents and defined the following terms and definitions apply to this specification. 3.1 Terms 3.1.1 radiation radiationsource Can emit or release device or substance of ionizing radiation. 3.1.2 The nominal X-ray tube current X-raytubecurrent Incident on the X-ray tube target beam current, generally indicated by the X-ray tube current of milliamps (mA). 3.1.3 (particle) fluence Ф particlefluence dN dα quotient obtained by dividing that Ф = dN/dα Where. dN --- the number of particles incident on the cross-section of the ball dα, m-2. 3.1.4 load time loadingtime Prescribed method measured the input power is applied to the anode X-ray tube time, usually in seconds (s) represented. 3.1.5 intrusive invasivetype Direct access to string a measure loop current mode measurements. 3.1.6 inductive non-intrusivetype Clamp meter head using a measure by way of measuring the induced electromotive force. 3.2 units of measurement 3.2.1 pipe name the amount of charge units. Library [Oakland], symbol. C.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJF 1459-2014_English be delivered?

Answer: Upon your order, we will start to translate JJF 1459-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJF 1459-2014_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1459-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.