HOME   Cart(1)   Quotation   About-Us Tax PDFs Standard-List
Powered by Google-Search & Google-Books www.ChineseStandard.net Database: 189760 (2 Jul 2022)

JJF 1113-2004

JJF 1113-2004_English: PDF (JJF1113-2004)
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)Related StandardStatusPDF
JJF 1113-2004English399 Add to Cart 3 days Calibration Specification of Angle Measuring Instrument for Bearing Ring JJF 1113-2004 Valid JJF 1113-2004

BASIC DATA
Standard ID JJF 1113-2004 (JJF1113-2004)
Description (Translated English) Calibration Specification of Angle Measuring Instrument for Bearing Ring
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A52
Classification of International Standard 17.040
Word Count Estimation 16,169
Date of Issue 2004-03-02
Date of Implementation 2004-09-02
Older Standard (superseded by this standard) JJG 783-1992
Quoted Standard JJF 1001-1998; JJF 1059-1999; JJF 1094-2002; JB/T 6637-1993; JJG 118-1996; JJG 396-2002
Drafting Organization Shandong Institute of Metrology
Administrative Organization National Technical Committee geometric angle measurement
Regulation (derived from) Administration of Quality Supervision, Inspection and Quarantine No. 24 of 2004
Issuing agency(ies) State Administration of Quality Supervision, Inspection and Quarantine
Summary This standard applies to standard parts bearing ring angle measuring instrument calibration.

JJF 1113-2004
Calibration Specification of Angle Measuring Instrument for Bearing Ring
National Metrology Technical Specification of the People's Republic
Bearing ring angle standard gauge measuring instrument calibration specification
Released on.2004-03-02
2004-09-02 implementation
The General Administration of Quality Supervision, Inspection and Quarantine issued
Bearing ring angle standard parts
Gauge calibration specification
Replace JJG783-1992
This specification was approved by the General Administration of Quality Supervision, Inspection and Quarantine on March 02,.2004, and
Implemented on September 2,.2004.
Focal Point. National Geometric Angle Measurement Technical Committee
Main drafting unit. Shandong Institute of Metrology
Participated in the drafting unit. Yantai Bearing Instrument Co., Ltd.
This specification entrusts the focal point to be responsible for interpretation
The main drafters of this specification.
Li Xiaohe (Shandong Institute of Metrology)
Xia Yuhong (Shandong Institute of Metrology)
Yu Zhishan (Shandong Institute of Metrology)
Participate in the drafters.
Sun Huiqing (Shandong Institute of Metrology)
Bao Yongde (Yantai Bearing Instrument Co., Ltd.)
table of Contents
1 range (1)
2 Citations (1)
3 Overview (1)
4 Measurement characteristics (1)
4.1 Surface roughness of each working surface (1)
4.2 Indicators (2)
4.3 Inductive force and force measurement of the indicating mechanism (2)
4.4 Proofreading cylinder (2)
4.5 Flatness of the sinusoidal gauge block support surface (2)
4.6 Flatness of the sinusoidal vertical arm working face (2)
4.7 Instrument Zero Error (2)
4.8 Instrument indication error (2)
4.9 Instrument repeatability (2)
5 Calibration conditions (3)
5.1 Environmental conditions (3)
5.2 Calibration Instruments and Other Equipment (3)
6 Calibration items and calibration methods (3)
6.1 Surface roughness of each working surface (3)
6.2 Indicators (3)
6.3 Inductive force and force measurement of the indicating mechanism (3)
6.4 Flatness of the sinusoidal gauge block support surface (3)
6.5 Flatness of sinusoidal vertical arm working face (3)
6.6 Instrument zero error (4)
6.7 Instrument indication error (4)
6.8 Instrument repeatability (5)
7 Calibration result expression (5)
8 re-study interval (5)
Appendix A Technical Requirements for Proofing Cylinders (6)
Appendix B Technical requirements for standard conical gauges (7)
Appendix C Uncertainty Analysis of Instrumental Indication Error Measurement Results (8)
Appendix D Calibration Certificate Contents (11)
Bearing ring angle standard gauge measuring instrument calibration specification
1 Scope
This specification applies to the calibration of the bearing ferrule angle standard measuring instrument.
2 Citations
This specification refers to the following documents.
JJF 1001-1998 General measurement terms and definitions
JJF 1059-1999 Measurement Uncertainty Evaluation and Representation
JJF 1094-2002 Measuring instrument characteristic evaluation
JB/T 6637-1993 Standard requirements for standard bearings for rolling bearings
JJG118-1996 Torsion spring type comparator verification procedure
JJG396-2002 Inductance Micrometer Calibration Procedure
Use of this specification should be done with the current valid version of the above cited documents.
3 Overview
Bearing ring angle standard measuring instrument (hereinafter referred to as angle measuring instrument) is mainly used for bearing ring angle standard parts
Measurement. The appearance of the instrument is shown in Figure 1 and Figure 2.
figure 1
1-base; 2-sine ruler; 3-correction cylinder; 4-sine ruled arm; 5--indication mechanism drive lever;
6- indicator sensor; 7-arm; 8-slide; 9-parallel rail
4 Measurement characteristics
4.1 Surface roughness of each working surface