HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

JJF 1280-2011 PDF English

US$215.00 · In stock · Download in 9 seconds
JJF 1280-2011: Calibration Specification for Capacitive Digital Scale Units
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid

JJF 1280: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] deliveryName of Chinese StandardStatus
JJF 1280-2011English215 Add to Cart 0-9 seconds. Auto-delivery Calibration Specification for Capacitive Digital Scale Units Valid
JJF 1280-1990English199 Add to Cart 2 days O.T.N. of the Primary Standard for Audiometric Zero Level of Air Conduction Obsolete

Excerpted PDFs (Download full copy in 9 seconds upon purchase)

PDF Preview: JJF 1280-2011
      

Similar standards

JJF 1406   JJF 1126   JJF 1960   

JJF 1280-2011: Calibration Specification for Capacitive Digital Scale Units

---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/JJF1280-2011
JJF METROLGICAL TECHNICAL SPECIFICATION OF THE PEOPLE’S REPUBLIC OF CHINA Calibration specification for capacitive digital scale units ISSUED ON: APRIL 12, 2011 IMPLEMENTED ON: JULY 12, 2011 Issued by: General Administration of Quality Supervision, Inspection and Quarantine of PRC.

Table of Contents

1 Scope ... 4 2 Normative references ... 4 3 Overview ... 4 4 Measurement characteristics ... 6 4.1 Indication error ... 6 4.2 Indication variability ... 6 4.3 Drift ... 6 5 Calibration conditions ... 6 5.1 Environmental conditions ... 6 5.2 Main calibration equipment ... 7 6 Calibration items and calibration methods ... 7 6.1 Indication error ... 7 6.2 Indication variability ... 10 6.3 Drift ... 10 7 Expression of calibration results ... 11 8 Recalibration time interval ... 11 Appendix A Uncertainty evaluation of the measurement result of the indication error of the capacitive digital scale unit ... 12 Appendix B Uncertainty evaluation of the indication error measurement result of the capacitive digital scale unit ... 14 Appendix C Contents of calibration certificate ... 17 Calibration specification for capacitive digital scale units

1 Scope

This Specification is applicable to the calibration of various specifications of capacitive digital scale units, which have a resolution of 0.005 mm, 0.01 mm, and a measurement range of (0 ~ 2000) mm.

2 Normative references

This Specification refers to the following documents: JJF 1001-1998 General terms in metrology and their definitions JJF 1059-1999 Evaluation and expression of uncertainty in measurement JJF 1094-2002 Evaluation of the characteristics of measuring instruments GB/T 22518-2008 Capacitive digital scale units When using this Specification, attention shall be paid to using the current valid versions of the above referenced documents.

3 Overview

The capacitive digital scale consists of a capacitive main scale and a running frame equipped with a capacitive digital display unit. It is a measuring instrument used to measure linear displacement. The schematic diagram of its appearance structure is shown in Figures 1 and 2. each measuring point, within the range of the capacitive digital scale unit, is taken as the indication error measurement result of the capacitive digital scale unit. 6.1.2 Gauge block measurement method The indication error of the non-enclosed capacitive digital scale unit, which has an upper limit of no more than 1000 mm, can also be measured by using 5-division gauge blocks in conjunction with a measuring fixture (see Figure 4 or Figure 5). The anvil of the measuring fixture is fixed on the main scale; the measuring plate is fixed on the running frame mounting plate. The difference between the above two measuring fixtures is that the ball probe of the measuring plate is in different positions; either one of them can be selected. When measuring, first move the running frame to make the ball probe of the measuring plate contact the measuring anvil's measuring surface; the display screen reads "zero". Then move the running frame; place a gauge block of the corresponding size between the ball probe and the measuring anvil's measuring surface for contact measurement; read the indication value from the display screen. The difference between the indication value of the capacitive digital scale unit and the actual size of the gauge block at each measuring point is the indication error of the measuring point. The difference between the maximum and minimum indication errors of each measuring point, within the measuring range, is taken as the indication error measurement result of the capacitive digital scale unit. The selection of measuring points refers to the provisions of 6.1.1. Note: The flatness and surface roughness of the measuring surface of the measuring anvil of the measuring fixture shall meet the requirements of the 5-division gauge block; when the measuring anvil is installed, the perpendicularity between the measuring surface of the measuring anvil and the guide surface of the capacitive digital scale is not greater than 10'. When the upper limit of measurement is not greater than 400 mm, the capacitive digital scale unit generally adopts horizontal measurement. When the upper limit of measurement is greater than 400 mm and less than or equal to 1000 mm, vertical measurement can be adopted.

Appendix A

Uncertainty evaluation of the measurement result of the indication error of the capacitive digital scale unit (Special measuring device measurement method) A.1 Measurement method According to this calibration Specification, the indication error of the capacitive digital scale unit, which has a resolution of 0.005 mm and a measurement upper limit of 300 mm, is measured using a special measuring device (in this example, a laser interferometer is used as a standard), to evaluate the uncertainty of the indication error measurement result. A.2 Mathematical model The mathematical model of the indication error of each measuring point is: Where: e - Indication error of the capacitive digital scale unit; l - Indication of the capacitive digital scale unit (under 20 °C); ls - Indication of the laser interferometer (under 20 °C). A.3 Variance and sensitivity coefficient Variance: Sensitivity coefficient: A.4 Standard uncertainties A.4.1 Uncertainty u(Δl) introduced by the variability (Δl) of the indication of the capacitive digital scale unit The indication variability (Δl) obeys a uniform distribution and affects the calibration process twice. The standard uncertainty introduced is:

Appendix B

Uncertainty evaluation of the indication error measurement result of the capacitive digital scale unit (Gauge block measurement method) B.1 Measurement method According to this calibration Specification, 5-division blocks are used to measure the indication error of the capacitive digital scale unit, which has a resolution of 0.005 mm and a measurement upper limit of 300 mm; the uncertainty of the indication error measurement result is evaluated. B.2 Mathematical model The mathematical model of the indication error of each measuring point is formula (1). Considering the influence of the measurement uncertainty factor during measurement, formula (1) is transformed into: Where: e - Indication error of the capacitive digital scale unit; l - Indication of the capacitive digital scale unit (under 20 °C); ls - Actual value of the size of 5-division gauge blocks (under 20 °C); L - Nominal size of the calibration point; - Average linear expansion coefficient of the capacitive digital scale unit and the gauge block; δt - Temperature difference between the capacitive digital scale unit and the gauge block; Δt - Difference between the average temperature of the capacitive digital scale unit and the gauge block to 20 °C; δα - Difference in linear expansion coefficient between the capacitive digital scale unit and the gauge block. B.3 Variance and sensitivity coefficient Variance: ......
Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.


      

Tips & Frequently Asked Questions

Question 1: How long will the true-PDF of English version of JJF 1280-2011 be delivered?

Answer: The full copy PDF of English version of JJF 1280-2011 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of JJF 1280-2011_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1280-2011_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. www.ChineseStandard.us -- JJF 1280-2011 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

Question 5: Should I purchase the latest version JJF 1280-2011?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJF 1280-2011 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.

How to buy and download a true PDF of English version of JJF 1280-2011?

A step-by-step guide to download PDF of JJF 1280-2011_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "JJF 1280-2011".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9