JG/T 302: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JG/T 302-2022 | English | RFQ |
ASK
|
3 days [Need to translate]
|
(Roller shutters)
| Valid |
JG/T 302-2022
|
JG/T 302-2011 | English | 999 |
Add to Cart
|
5 days [Need to translate]
|
Rolling doors and windows
| Obsolete |
JG/T 302-2011
|
PDF similar to JG/T 302-2022
Basic data Standard ID | JG/T 302-2022 (JG/T302-2022) | Description (Translated English) | (Roller shutters) | Sector / Industry | Building & Construction Industry Standard (Recommended) | Classification of Chinese Standard | Q70;Q74 | Classification of International Standard | 91.060.50 | Date of Issue | 2022-04-06 | Date of Implementation | 2022-08-01 | Issuing agency(ies) | Ministry of Housing and Urban-Rural Development of the People's Republic of China |
JG/T 302-2011: Rolling doors and windows---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Rolling doors and windows
ICS 91.060.50
Q70/74
People's Republic of China building industry standards
Replacing JG/T 3039-1997
Shutter doors and windows
2011-02-17 released
2011-08-01 implementation
Ministry of Housing and Urban-Rural Development, People's Republic of China released
Directory
Foreword Ⅲ
1 Scope 1
2 Normative references 1
3 Terms and definitions 2
4 classification, code and mark 2
5 material 4
6 Requirements 6
7 Test methods 10
Inspection rules 12
9 logo, packaging, transportation and storage 13
Appendix A (informative) product structure type 15
Appendix B (informative) Installation 21
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard replaces JG/T 3039-1997 "light metal doors and windows."
This standard is a revision of JG/T 3039-1997, compared with the JG/T 3039-1997 main changes are as follows.
--- Added Chapter 3 Terms and Definitions, Chapter 5 Materials;
--- Added about cavity-filled curtain tablets and filler content;
--- Increased on the rapid shutter door content;
--- Increasing the number of repeated opening and closing requirements;
--- Increased wind pressure, insulation, sound insulation physical performance requirements;
--- Modify the classification method, an increase of classification according to curtain structure, according to the material classification, driven by the classification, in the wind pressure performance classification
An increase of 20, 35.
This standard proposed by the Ministry of Housing and Urban Standard and Design Institute.
This standard by the Ministry of Housing and Urban Construction Building Products and Components Products Standardization Technical Committee.
This standard is drafted by. Xiamen Comfort Heart Door Co., Ltd.
Participated in the drafting of this standard. Bamboo Industry Co., Ltd. Jiangsu autumn, Hunan Hunan Science and Technology Co., Ltd., Wuzhu Zhengguo Machinery Technology open
Co., Ltd., Jiangyin Beit Door Industry Co., Ltd., Hangzhou Taixin Industrial Co., Ltd., Hohmann (Beijing) Co., Ltd., Liaoning Shengwei machine
Electric Technology Co., Ltd., Paul policy can be Mai Mai Technology (Suzhou) Co., Ltd., Wuxi Ji Anda Door Co., Ltd. Xu Ji Spread Electrical and Mechanical Equipment
Co., Ltd., Shanghai Peifu Automation Control Equipment Co., Ltd., Langfang City An Han Hardware Doors and Windows Factory, Ningbo Duya Electromechanical Technology Co., Ltd., on
Sea when the United States Industrial Co., Ltd., still fly shutter doors and windows equipment (Shanghai) Co., Ltd., Shanghai Baoan Sanhe Door Co., Ltd., Zhangzhou City,
Electric Co., Ltd.
The main drafters of this standard. Zhang Zhaohui, Tang Zongzhi, Lu Zhengfei, Chen Yumei, Chen Jixiang, Liu Shaochang, Shi Jiangang, Zhang Lianfa, Yang Guangxu,
Yu Jian, Yang Chengqiang, Zhao Xuerong, Yang Jie, Liu Ruyan, Han Zhishen, Sun Yong, Chang Jin, Yin Jun, Chen Yanmei, Zhong You students.
This standard was first released in.1997, the first revision in.2010.
Shutter doors and windows
1 Scope
This standard specifies the terms and definitions shutter doors and windows, classification, code and markings, materials, requirements, test methods, inspection rules, signs, packages
Loading, transportation and storage.
This standard applies to industrial and civil construction shutter doors and windows.
This standard does not apply to side shutter doors and windows and have fire, security and other special requirements shutter doors and windows. Other non-metallic shutter doors and windows can be
Refer to the implementation.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version applies to this article
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 700 carbon structural steel
GB/T 716 carbon structural steel cold-rolled strip
GB/T 1222 spring steel
GB/T 2518 continuous hot dip galvanized steel sheet and strip
GB/T 3880.1 General industrial aluminum and aluminum alloy sheet, strip - Part 1. General requirements
GB/T 3880.2 General industrial aluminum and aluminum alloy sheet, strip - Part 2. Mechanical properties
GB/T 4239 stainless steel and heat-resistant steel cold-rolled strip
GB/T 4357 carbon spring steel wire
GB 4706.1 Safety of household and similar electrical appliances - Part 1. General requirements
GB 5237.1 aluminum alloy building profiles - Part 1. Substrate
GB 5237.2 aluminum alloy building profiles - Part 2. Anodized profiles
GB 5237.3 aluminum alloy building profiles - Part 3. Electrophoretic paint profiles
GB 5237.4 aluminum alloy building profiles - Part 4. Powder coating profiles
GB 5237.5 aluminum alloy building profiles - Part 5. fluorocarbon spray profiles
GB/T 5761 suspension of general-purpose polyvinyl chloride resin
GB/T 5823 building doors and windows terminology
GB/T 5824 building doors and windows hole size series
GB/T 7106 exterior doors and windows airtight, watertight, wind pressure performance grading and testing methods
GB/T 8162 structural seamless steel tubes
GB/T 8484 building exterior doors and windows insulation performance classification and testing methods
GB/T 8485 Building exterior windows and doors air sound insulation performance classification and detection methods
GB 11116 high-density polyethylene resin
GB/T 12670 polypropylene (PP) resin
GB 12672 acrylonitrile - butadiene - styrene (ABS) resin
GB/T 12754 color coated steel sheet and strip