HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

GB/T 7000.202-2023 English PDF

US$369.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 7000.202-2023: Luminaires - Part 2-2: Particular requirements - Recessed luminaires
Status: Valid

GB/T 7000.202: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 7000.202-2023English369 Add to Cart 4 days [Need to translate] Luminaires - Part 2-2: Particular requirements - Recessed luminaires Valid GB/T 7000.202-2023
GB 7000.202-2008English399 Add to Cart 3 days [Need to translate] Luminaires -- Part 2-2: Particular requirements -- Recessed luminaires Obsolete GB 7000.202-2008

PDF similar to GB/T 7000.202-2023


Standard similar to GB/T 7000.202-2023

GB/T 7000.204   GB/T 7000.201   GB 7000.204   GB/T 7000.211   GB/T 7000.212   GB/T 7000.208   

Basic data

Standard ID GB/T 7000.202-2023 (GB/T7000.202-2023)
Description (Translated English) Luminaires - Part 2-2: Particular requirements - Recessed luminaires
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard K72
Classification of International Standard 29.140
Word Count Estimation 18,157
Date of Issue 2023-12-28
Date of Implementation 2026-01-01
Older Standard (superseded by this standard) GB 7000.202-2008; GB 7000.219-2008
Issuing agency(ies) State Administration for Market Regulation, China National Standardization Administration

GB/T 7000.202-2023: Luminaires - Part 2-2: Particular requirements - Recessed luminaires

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
ICS 29:140 CCSK72 National Standards of People's Republic of China Replace GB 7000:202-2008, GB 7000:219-2008 Luminaires Part 2-2: Special Requirements recessed lighting Recessed luminaires Published on 2023-12-28 Implemented on 2026-01-01 State Administration for Market Regulation Released by the National Standardization Administration Committee

Table of contents

Preface III Introduction V 1 Scope 1 2 Normative references 1 3 Terms and Definitions 1 4 General test requirements 1 5 Classification of lamps 2 6 marks 2 7 Structure 2 8 Creepage distances and clearances 2 9 Grounding regulations 3 10 Terminal 3 11 External and internal wiring 3 12 Protection against electric shock 3 13 Durability test and thermal test 3 14 Protection against dust, solid foreign objects and water 4 15 Insulation resistance and electrical strength 4 16 Resistant to heat, fire and marking 4 Appendix A (Normative) Measurement of ambient temperature in facilities 5 Appendix B (Normative) Thermal test of recessed lamps 6 Appendix C (informative) Explanation on ventilation lighting fixtures 8 Appendix D (informative) List of modified sub-clauses for more stringent or critical requirements that require retesting 9 Reference 10

Foreword

This document complies with the provisions of GB/T 1:1-2020 "Standardization Work Guidelines Part 1: Structure and Drafting Rules of Standardization Documents" Drafting: This document is part 2-2 of GB (/T)7000: GB (/T)7000 has released the following parts: ---Lamps Part 1: General requirements and tests (GB/T 7000:1-2023); ---Lamps Part 2-1: Fixed universal lamps with special requirements (GB/T 7000:201-2023); ---Lamps Part 2-3: Special requirements for road and street lighting fixtures (GB 7000:203-2013); ---Lamps Part 2-4: Movable general-purpose lamps with special requirements (GB/T 7000:204-2023); ---Lamps Part 2-5: Special requirements for floodlights (GB/T 7000:205-2023); ---Lamps Part 2-6: Special requirements for lamps with built-in tungsten filament lamp transformers or converters (GB 7000:6-2008); ---Lamps Part 2-8: Special requirements portable lamps (GB/T 7000:208-2023); ---Safety requirements for lighting fixtures for photography and film (non-professional use) (GB 7000:19-2005); ---Lamps Part 2-10: Special requirements for removable lamps for children (GB 7000:4-2007); ---Lamps Part 2-11: Special requirements for aquarium lamps (GB/T 7000:211-2023); ---Lamps Part 2-12: Night lights with special requirements for power socket installation (GB/T 7000:212-2023); ---Lamps Part 2-13: Special requirements for ground recessed lamps (GB/T 7000:213-2023); ---Lamps Part 2-14: Special requirements for lamps using cold cathode tubular discharge lamps (neon lamps) and similar equipment (GB 7000:214-2015); ---Lamps Part 2-17: Special requirements for stage lighting, television, film and photography venues (indoor and outdoor) (GB/T 7000:217-2023); ---Lamps Part 2-18: Special requirements for lamps for swimming pools and similar places (GB/T 7000:218-2023); ---Lamps Part 2-20: Special requirements for light strings (GB/T 7000:220-2023); ---Lamps Part 2-21: Special requirements for light strips (GB/T 7000:221-2023); ---Lamps Part 2-22: Special requirements for emergency lighting fixtures (GB/T 7000:222-2023); ---Lamps Part 2-23: Special requirements for extra-low voltage (ELV) lighting systems for light sources (GB/T 7000:223- 2023); ---Lamps Part 2-24: Special requirements for surface temperature lamps (GB/T 7000:224-2023); ---Lamps Part 2-25: Special requirements for lamps used in hospitals and rehabilitation building clinics (GB 7000:225-2008): This document replaces GB 7000:202-2008 "Lamps - Part 2-2: Special Requirements for Embedded Lamps" and GB 7000:219- 2008 "Lamps Part 2-19: Ventilated luminaires with special requirements": This document is mainly based on GB 7000:202-2008 and integrates Contents of GB 7000:219-2008: Compared with GB 7000:202-2008, in addition to structural adjustments and editorial changes, the main technical changes as follows: a) Changed the “scope” of the standard (see Chapter 1, Chapter 1 of GB 7000:202-2008); b) Added the content of “Terms and Definitions” (see Chapter 3, Chapter 3 of GB 7000:202-2008); c) Added the "General test requirements" clause (see Chapter 4); d) The content of "marking" is added (see 6:1~6:4), and the "F mark of thermal insulation ceiling" is deleted (see GB 7000:202-2008 5:1); e) The provisions on "impact energy and spring compression of the embedded part of the lamp" are deleted (see Chapter 6 of GB 7000:202-2008); f) Changed the standards that the mechanical and electrical properties of "external wiring and internal wiring" should comply with (see Chapter 11, GB 7000:202- Chapter 10 of:2008); g) Added the installation and test requirements of Appendix B in "Durability and Thermal Test" (see 13:2), and the test strips for the thermal test of ventilated lamps parts and temperature limits (see 13:4); h) Added IP test requirements for recessed parts of recessed lighting fixtures (see 14:3); i) Appendix A "Measurement of ambient temperature in facilities" has been changed (see Appendix A, Appendix A of GB 7000:202-2008); j) Added Appendix B "Thermal Test of Recessed Lamps": Compared with GB 7000:219-2008, in addition to structural adjustments and editorial changes, the main technical changes are as follows: a) Changed the “scope” of the standard (see Chapter 1, Chapter 1 of GB 7000:219-2008); b) Added the "General test requirements" clause (see Chapter 4); c) Changed the classification description of lamps (see Chapter 5, Chapter 4 of GB 7000:219-2008); d) Added the content of "marking" (see 6:1~6:4), deleted the content of "ventilated lamps" mark (see GB 7000:219-2008 5:1~5:4); e) The content of “structure” has been changed (see Chapter 7, Chapter 6 of GB 7000:219-2008); f) Changed the standards that the mechanical and electrical properties of "external wiring and internal wiring" should comply with (see Chapter 11, GB 7000:219- Chapter 10 of:2008); g) Added the content of "protection against electric shock" (see Chapter 12); h) Changed the content of "durability test and thermal test" (see Chapter 13, Chapter 12 of GB 7000:219-2008); i) Added IP test requirements for recessed parts of recessed lighting fixtures (see 14:3); j) Changed normative Appendix A "Measurement of ambient temperature in facilities" (see Appendix A, Appendix A of GB 7000:219-2008); k) Added normative appendix B "Thermal Test of Recessed Lamps": This document is modified to adopt IEC 60598-2-2:2023 "Lamps Part 2-2: Special Requirements for Recessed Luminaires": The technical differences between this document and IEC 60598-2-2:2023 and their reasons are as follows: ---Modified the scope of Chapter 1 to comply with the writing requirements of our country's standards; ---Replaced IEC 60598-1 with normatively quoted GB/T 7000:1 to facilitate the application of the series of standards: Please note that some content in this document may be subject to patents: The publisher of this document assumes no responsibility for identifying patents: This document is proposed by China Light Industry Federation: This document is under the jurisdiction of the National Lighting Appliances Standardization Technical Committee (SAC/TC224): This document was drafted by: Huizhou NVC Optoelectronics Technology Co:, Ltd:, Shanghai Institute of Quality Supervision and Inspection Technology, Shanghai Times Lighting Ming Electrical Testing Co:, Ltd:, Xiamen Lidaxin Digital Education Technology Co:, Ltd:, Ningbo Bull Optoelectronics Technology Co:, Ltd:, Haixing Maritime Electric Group Co:, Ltd:, Zhejiang Sunshine Lighting Electrical Appliances Group Co:, Ltd:, and Shanghai Municipal Education Commission Educational Technology Equipment Center: The main drafters of this document: Zhao Zhubo, Xiong Fei, Xu Jianxing, Liu Bingren, Fu Wenlong, Chen Yiping, Ouyang Fang, Li Mei, Jiang Lili, Yu Zaidao, Yang Yue: The previous versions of this document and the documents it replaces are as follows: ---First published in 1988 as GB 9472-1988; first revised in:1999, adjusted to GB 7000:12-1999;:2008 Second revision, adjusted to GB 7000:202-2008; ---This is the third revision, incorporating the contents of GB 7000:219-2008: Previous versions of GB 7000:219-2008 have been released:

Introduction

GB (/T)7000 "Lamps" is intended to consist of the following parts: ---Part 1: General requirements and tests: The purpose is to specify the use of electric light sources and lamps with a power supply voltage not exceeding 1000V: General requirements: ---Part 2-1: Special requirements for fixed general-purpose luminaires: The purpose is to stipulate that the power supply voltage does not exceed 1000V for electro-optical Requirements for fixed general-purpose luminaires whose source is a light source: ---Part 2-2: Special requirements for recessed lighting fixtures: The purpose is to stipulate that the power supply voltage does not exceed 1000V and the electric light source is used as the light source: source of recessed light fixtures: ---Part 2-3: Special requirements for road and street lighting fixtures: The purpose is to stipulate that the power supply voltage of the electric light source does not exceed Requirements for 1000V lighting fixtures for roads, street lighting and other outdoor public places, as well as tunnel lighting and normal ground lighting Requirements for column-type synthetic luminaires with a minimum total height above the surface of 2:5m: ---Part 2-4: Removable general-purpose lamps with special requirements: Purpose is to provide for indoor and/or outdoor use other than portable lamps Requirements for portable general-purpose lamps with power supply voltage not exceeding 250V and using electric light sources as light sources (such as for courtyard use): ---Part 2-5: Special requirements for floodlights: The purpose is to stipulate the use of electric light sources and power supply voltages not exceeding 1000V: lighting requirements: ---Part 2-8: Special requirements for portable lamps: The purpose is to stipulate the use of portable electric light sources with a power supply voltage not exceeding 250V: Requirements for lamps and similar portable luminaires: ---Part 2-10: Removable lamps for children with special requirements: The purpose is to stipulate the safety requirements for removable lamps for children: Use tungsten lamps or single-ended fluorescent lamps with a power supply voltage not exceeding 250V: ---Part 2-11: Special requirements for aquarium lighting fixtures: The purpose is to stipulate the use of electric light sources with a power supply voltage not exceeding 1000V Special requirements for home aquarium lighting fixtures: ---Part 2-12: Night lights with special requirements for power outlet installation: The purpose is to stipulate the use of electric light sources and power supply voltages not exceeding Requirements for night lights installed in AC 250V50/60Hz power sockets: ---Part 2-13: Special requirements for ground recessed lighting fixtures: The purpose is to stipulate the use of electric light sources and the power supply voltage does not exceed 1000V Requirements for ground recessed lighting fixtures: ---Part 2-14: Special requirements for the use of cold cathode tubular discharge lamps (neon lamps) and similar equipment: The purpose is to stipulate The power supply voltage does not exceed 1000V and the no-load rated output voltage is greater than 1000V but not more than 10000V: Requirements for the manufacture and use of cold cathode tubular discharge lamps and similar equipment: ---Part 2-17: Special requirements for stage lighting, television, film and photography venues (indoor and outdoor) lighting fixtures: The purpose is to provide for the Electric light source, power supply voltage does not exceed 1000V, used in outdoor and indoor stage lighting, television, movie and photography venues Requirements for luminaires (including spot and floodlight projections): ---Part 2-18: Special requirements for lighting fixtures in swimming pools and similar places: The purpose is to provide for use in water or contact with water Safety requirements for fixed luminaires: ---Part 2-20: Special requirements for light strings: The purpose is to stipulate that the power supply voltage does not exceed 250V and is used for indoor or outdoor installations: Safety requirements for light strings with light sources connected in series, parallel or a series/parallel combination: ---Part 2-21: Special requirements for light strips: The purpose is to stipulate that the power supply voltage does not exceed 250V and is used indoors or outdoors: There are safety requirements for light strips (sealed light strings) that are irreplaceable in series or parallel and combinations of series and parallel light sources: ---Part 2-22: Special requirements for emergency lighting fixtures: The purpose is to stipulate that the emergency power supply voltage does not exceed 1000V: Light source requirements for emergency lighting fixtures: ---Part 2-23: Special requirements for extra-low voltage (ELV) light sources and extra-low voltage lighting systems: The purpose is to specify the supply voltage Requirements for extra-low voltage lighting systems for extra-low voltage (ELV) light sources not exceeding 1000V for ordinary indoor use: ---Part 2-24: Special requirements limiting surface temperature lamps: The purpose is to stipulate that the power supply voltage of the electric light source does not exceed 1000V lamps used in places where the outer surface temperature of the lamp needs to be limited due to thermal effects, risk of material burning or deterioration Require: ---Part 2-25: Special requirements for lamps used in hospitals and rehabilitation building clinics: The purpose is to regulate the use of tungsten lamps, fluorescent lamps and other Other gas discharge lamps are used as light sources and the power supply voltage does not exceed 1000V for medical treatment and examination in clinics and in hospitals: and safety requirements for lighting fixtures used in medical care in rehabilitation buildings: When any clause of GB/T 7000:1 is quoted in this document, it stipulates the scope of application of the clause and the test sequence of each test, and stipulates Necessary additional requirements are set: Luminaires Part 2-2: Special Requirements recessed lighting

1 Scope

This document specifies the requirements for recessed luminaires and recessed ventilation ducts for use with ventilation ducts or ventilation spaces (ventilation chambers): Requirements for wind-type lamps: This document applies to lamps with a power supply voltage not exceeding 1000V and using electric light sources as light sources: This document does not apply to ventilated luminaires or liquid-cooled luminaires: NOTE: The terms "ventilation" and "ventilated" in this document refer to forced ventilation:

2 Normative reference documents

The contents of the following documents constitute essential provisions of this document through normative references in the text: Among them, the dated quotations For undated referenced documents, only the version corresponding to that date applies to this document; for undated referenced documents, the latest version (including all amendments) applies to this document: GB/T 7000:1 Luminaires Part 1: General requirements and tests (GB/T 7000:1-2023, IEC 60598-1:2020, MOD) Note: GB/T 5023 (all parts) Polyvinyl chloride insulated cables with rated voltage 450/750V and below [IEC 60227 (all parts)] Note: GB/T 5013 (all parts) Rubber insulated cables with rated voltage 450/750V and below [IEC 60245 (all parts)]

3 Terms and definitions

The following terms and definitions apply to this document: 3:1 air-handlingluminaire A light fixture specially designed for use in conjunction with an air conditioning system: Note 1: Air may pass through the light source cavity or a separate ventilation duct: Note 2: For the explanation of ventilated lamps ta, see Appendix C: 3:2 static operation staticoperation A working state of the lamp that neither forced ventilation nor exhaust, but allows air convection:

4 General test requirements

The provisions of Chapter 0 of Part 1 1) apply: The tests described in the corresponding clauses in Part 1 shall be carried out in the order listed in this document: 1) The "Part 1" mentioned in this document refers to GB/T 7000:1: The measurement process of ambient temperature in the facility is in accordance with Appendix A:

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 7000.202-2023_English be delivered?

Answer: Upon your order, we will start to translate GB/T 7000.202-2023_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 7000.202-2023_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 7000.202-2023_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 7000.202-2023?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 7000.202-2023 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.