US$289.00 ยท In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 7000.205-2023: Luminaires - Part 2-5: Particular requirements - Floodlights Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GB/T 7000.205-2023 | English | 289 |
Add to Cart
|
3 days [Need to translate]
|
Luminaires - Part 2-5: Particular requirements - Floodlights
| Valid |
GB/T 7000.205-2023
|
PDF similar to GB/T 7000.205-2023
Basic data Standard ID | GB/T 7000.205-2023 (GB/T7000.205-2023) | Description (Translated English) | Luminaires - Part 2-5: Particular requirements - Floodlights | Sector / Industry | National Standard (Recommended) | Classification of Chinese Standard | K72 | Classification of International Standard | 29.140 | Word Count Estimation | 14,122 | Date of Issue | 2023-12-28 | Date of Implementation | 2026-01-01 | Older Standard (superseded by this standard) | GB 7000.7-2005 | Issuing agency(ies) | State Administration for Market Regulation, China National Standardization Administration |
GB/T 7000.205-2023: Luminaires - Part 2-5: Particular requirements - Floodlights---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
ICS 29:140
CCSK72
National Standards of People's Republic of China
Replace GB 7000:7-2005
Luminaires Part 2-5: Floodlights with special requirements
(IEC 60598-2-5:2015, MOD)
Published on 2023-12-28
Implemented on 2026-01-01
State Administration for Market Regulation
Released by the National Standardization Administration Committee
Table of contents
Preface III
Introduction V
1 Scope 1
2 Normative references 1
3 Terms and Definitions 1
4 Lamps Classification 1
5 marks 2
6 Structure 2
7 Creepage distances and clearances 4
8 Grounding regulations 4
9 Terminal 4
10 External and internal wiring 4
11 Protection against electric shock 4
12 Durability test and thermal test 4
13 Dustproof and waterproof 5
14 Insulation resistance and electrical strength 5
15 Resistant to heat, fire and marking 5
Appendix A (informative) List of modified clauses for more stringent or critical requirements that require retesting 6
Figure 1 Counting the number of particles on the edge of a square 3
Foreword
This document complies with the provisions of GB/T 1:1-2020 "Standardization Work Guidelines Part 1: Structure and Drafting Rules of Standardization Documents"
Drafting:
This document is part 2-5 of GB (/T)7000: GB (/T)7000 has released the following parts:
---Lamps Part 1: General requirements and tests (GB/T 7000:1-2023);
---Lamps Part 2-1: Fixed universal lamps with special requirements (GB/T 7000:201-2023);
---Lamps Part 2-2: Special requirements for embedded lamps (GB/T 7000:202-2023);
---Lamps Part 2-3: Special requirements for road and street lighting fixtures (GB 7000:203-2013);
---Lamps Part 2-4: Movable general-purpose lamps with special requirements (GB/T 7000:204-2023);
---Lamps Part 2-6: Special requirements for lamps with built-in tungsten filament lamp transformers or converters (GB 7000:6-2008);
---Lamps Part 2-8: Special requirements portable lamps (GB/T 7000:208-2023);
---Safety requirements for lighting fixtures for photography and film (non-professional use) (GB/T 7000:19-2005);
---Lamps Part 2-10: Special requirements for removable lamps for children (GB 7000:4-2007);
---Lamps Part 2-11: Special requirements for aquarium lamps (GB/T 7000:211-2023);
---Lamps Part 2-12: Night lights with special requirements for power socket installation (GB/T 7000:212-2023);
---Lamps Part 2-13: Special requirements for ground recessed lamps (GB/T 7000:213-2023);
---Lamps Part 2-14: Special requirements for lamps using cold cathode tubular discharge lamps (neon lamps) and similar equipment
(GB 7000:214-2015);
---Lamps Part 2-17: Special requirements for stage lighting, television, film and photography venues (indoor and outdoor)
(GB/T 7000:217-2023);
---Lamps Part 2-18: Special requirements for lamps for swimming pools and similar places (GB/T 7000:218-2023);
---Lamps Part 2-20: Special requirements for light strings (GB/T 7000:220-2023);
---Lamps Part 2-21: Special requirements for light strips (GB/T 7000:221-2023);
---Lamps Part 2-22: Special requirements for emergency lighting fixtures (GB/T 7000:222-2023);
---Lamps Part 2-23: Special requirements for extra-low voltage (ELV) lighting systems for light sources (GB/T 7000:223-
2023);
---Lamps Part 2-24: Special requirements for surface temperature lamps (GB/T 7000:224-2023);
---Lamps Part 2-25: Special requirements for lamps used in hospitals and rehabilitation building clinics (GB 7000:225-2008):
This document replaces GB 7000:7-2005 "Safety Requirements for Flood Lights": Compared with GB 7000:7-2005, except for structural adjustments and editing
In addition to sexual changes, the main technical changes are as follows:
a) Changed the scope of application (see Chapter 1, Chapter 1 of the:2005 edition);
b) The content that should be included in the installation instructions has been changed, stipulating that there should be information on the maximum installation height of lamps (see Chapter 5,:2005 edition)
Chapter 5);
c) Changed the requirements for formed glass covers and high-strength glass covers (see 6:8,:2005 version of 6:8);
d) Changed the requirements for glass surface temperature (see Chapter 12, Chapter 12 of the:2005 edition):
This document is modified to adopt IEC 60598-2-5:2015 "Lamps Part 2-5: Special Requirements for Floodlight Luminaires":
The technical differences between this document and IEC 60598-2-5:2015 and their reasons are as follows:
---Changed the scope of Chapter 1 to comply with the writing requirements of our country's standards;
---Replaced IEC 60598-1 with normatively quoted GB/T 7000:1 to facilitate the application of the series of standards:
Please note that some content in this document may be subject to patents: The publisher of this document assumes no responsibility for identifying patents:
This document is proposed by China Light Industry Federation:
This document is under the jurisdiction of the National Lighting Appliances Standardization Technical Committee (SAC/TC224):
This document was drafted by: Weikai Testing Technology Co:, Ltd:, Hangzhou Huapu Yongming Optoelectronics Co:, Ltd:, Xiamen Lidaxin Lighting Co:, Ltd:
Company, Chenhui Guangbao Technology Co:, Ltd:, Huizhou NVC Optoelectronics Technology Co:, Ltd:, Huzhou Tianshi Glass Products Co:, Ltd:, Jiangsu Yashi Lighting
Group Co:, Ltd:, Beijing Qingcheng Pinsheng Lighting Research Institute Co:, Ltd:, Shanghai Times Lighting Electrical Testing Co:, Ltd:, Shanghai Quality
Institute of Supervision and Inspection Technology:
The main drafters of this document: Ni Jiyu, Huang Jianming, Chen Yuchang, Yang Jiabi, Xiao Qiuxia, Song Weirong, Yin Jinxing, Ma Ye, Shi Xiaohong:
The previous versions of this document and the documents it replaces are as follows:
---First published as GB 7000:7-1997 in:1997, first revised in:2005;
Introduction
GB (/T)7000 "Lamps" is intended to consist of the following parts:
---Part 1: General requirements and tests: The purpose is to specify the use of electric light sources and lamps with a power supply voltage not exceeding 1000V:
General requirements:
---Part 2-1: Special requirements for fixed general-purpose luminaires: The purpose is to stipulate that the power supply voltage does not exceed 1000V for electro-optical
Requirements for fixed general-purpose luminaires whose source is a light source:
---Part 2-2: Special requirements for recessed lighting fixtures: The purpose is to stipulate that the power supply voltage does not exceed 1000V and the electric light source is used as the light source:
source of recessed light fixtures:
---Part 2-3: Special requirements for road and street lighting fixtures: The purpose is to stipulate that the power supply voltage of the electric light source does not exceed
Requirements for 1000V lighting fixtures for roads, street lighting and other outdoor public places, as well as tunnel lighting and normal ground lighting
Requirements for column-type synthetic luminaires with a minimum total height above the surface of 2:5m:
---Part 2-4: Removable general-purpose lamps with special requirements: Purpose is to provide for indoor and/or outdoor use other than portable lamps
Requirements for portable general-purpose lamps with power supply voltage not exceeding 250V and using electric light sources as light sources (such as for courtyard use):
---Part 2-5: Special requirements for floodlights: The purpose is to stipulate the use of electric light sources and power supply voltages not exceeding 1000V:
lighting requirements:
---Part 2-8: Special requirements for portable lamps: The purpose is to stipulate the use of portable electric light sources with a power supply voltage not exceeding 250V:
Requirements for lamps and similar portable luminaires:
---Part 2-10: Removable lamps for children with special requirements: The purpose is to stipulate the safety requirements for removable lamps for children:
Use tungsten lamps or single-ended fluorescent lamps with a power supply voltage not exceeding 250V:
---Part 2-11: Special requirements for aquarium lighting fixtures: The purpose is to stipulate the use of electric light sources with a power supply voltage not exceeding 1000V
Special requirements for home aquarium lighting fixtures:
---Part 2-12: Night lights with special requirements for power socket installation: The purpose is to stipulate the use of electric light sources and power supply voltages not exceeding
Requirements for night lights installed in AC 250V50/60Hz power sockets:
---Part 2-13: Special requirements for ground recessed lighting fixtures: The purpose is to stipulate the use of electric light sources and the power supply voltage does not exceed 1000V
Requirements for ground recessed lighting fixtures:
---Part 2-14: Special requirements for the use of cold cathode tubular discharge lamps (neon lamps) and similar equipment: The purpose is to stipulate
The power supply voltage does not exceed 1000V and the no-load rated output voltage is greater than 1000V but not more than 10000V:
Requirements for the manufacture and use of cold cathode tubular discharge lamps and similar equipment:
---Part 2-17: Special requirements for stage lighting, television, film and photography venues (indoor and outdoor) lighting fixtures: The purpose is to provide for the
Electric light source, power supply voltage does not exceed 1000V, used in outdoor and indoor stage lighting, television, movie and photography venues
Requirements for luminaires (including spot and floodlight projections):
---Part 2-18: Special requirements for lighting fixtures in swimming pools and similar places: The purpose is to provide for use in water or contact with water
Safety requirements for fixed luminaires:
---Part 2-20: Special requirements for light strings: The purpose is to stipulate that the power supply voltage does not exceed 250V and is used for indoor or outdoor installations:
Safety requirements for light strings with light sources connected in series, parallel or a series/parallel combination:
---Part 2-21: Special requirements for light strips: The purpose is to stipulate that the power supply voltage does not exceed 250V and is used indoors or outdoors:
There are safety requirements for light strips (sealed light strings) that are irreplaceable in series or parallel and combinations of series and parallel light sources:
---Part 2-22: Special requirements for emergency lighting fixtures: The purpose is to stipulate that the emergency power supply voltage does not exceed 1000V:
Light source requirements for emergency lighting fixtures:
---Part 2-23: Special requirements for extra-low voltage (ELV) light sources and extra-low voltage lighting systems: The purpose is to specify the supply voltage
Requirements for extra-low voltage lighting systems for extra-low voltage (ELV) light sources not exceeding 1000V for ordinary indoor use:
---Part 2-24: Special requirements limiting surface temperature lamps: The purpose is to stipulate that the power supply voltage of the electric light source does not exceed
1000V lamps used in places where the outer surface temperature of the lamp needs to be limited due to thermal effects, risk of material burning or deterioration
Require:
---Part 2-25: Special requirements for lamps used in hospitals and rehabilitation building clinics: The purpose is to regulate the use of tungsten lamps, fluorescent lamps and other
Other gas discharge lamps are used as light sources and the power supply voltage does not exceed 1000V for medical treatment and examination in clinics and in hospitals:
and safety requirements for lighting fixtures used in medical care in rehabilitation buildings:
When any clause of GB/T 7000:1 is quoted in this document, it stipulates the scope of application of the clause and the test sequence of each test, and stipulates
Necessary additional requirements are set:
Luminaires Part 2-5: Floodlights with special requirements
1 Scope
This document specifies the requirements for floodlight luminaires:
This document applies to floodlights that use electric light sources and whose power supply voltage does not exceed 1000V:
2 Normative reference documents
The contents of the following documents constitute essential provisions of this document through normative references in the text: Among them, the dated quotations
For undated referenced documents, only the version corresponding to that date applies to this document; for undated referenced documents, the latest version (including all amendments) applies to
this document:
GB/T 7000:1 Luminaires Part 1: General requirements and tests (GB/T 7000:1-2023, IEC 60598-1:2020, MOD)
Part 2-75:Tests-TestEh:Hammertests)
Note: GB/T 2423:55-2023 Environmental testing Part 2: Test method Test Eh: Hammer test (IEC 60068-2-75:2014, IDT)
Note: GB/T 20138-2023 Protection level of electrical equipment enclosures against external mechanical impact (IK code) (IEC 62262:2021, IDT)
3 Terms and definitions
The terms and definitions defined in Part 1 1) and below apply to this document:
3:1
Floodlighting
In order to have significantly higher illumination than its surrounding environment, a surface or object is usually illuminated by a projector:
Note: Color can be used to achieve lighting differences between the illuminated object and its surrounding environment:
3:2
Floodlight
Lamps used as cast lighting:
Note: Floodlights can be used alone for outdoor or indoor use, or for both at the same time:
4 Lamps classification
Luminaires shall be classified in accordance with the provisions of Part 1, Chapter 2: The provisions of Part 1, Chapter 0 apply: Each corresponding in Part 1
The tests specified in the chapters shall be carried out in the order listed in this document:
See Appendix A for a list of more stringent or critical requirements requiring retesting:
1) The "Part 1" mentioned in this document refers to GB/T 7000:1:
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 7000.205-2023_English be delivered?Answer: Upon your order, we will start to translate GB/T 7000.205-2023_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 7000.205-2023_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 7000.205-2023_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|