HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (12 Oct 2025)

GB/T 33555-2025 English PDF

US$459.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 33555-2025: Cleanrooms and associated controlled environments - Technical requirements of electrostatic control
Status: Valid

GB/T 33555: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 33555-2025English459 Add to Cart 4 days [Need to translate] Cleanrooms and associated controlled environments - Technical requirements of electrostatic control Valid GB/T 33555-2025
GB/T 33555-2017English259 Add to Cart 3 days [Need to translate] Cleanroom and associated controlled environments technical guidelines of electrostatic discharge control Valid GB/T 33555-2017

PDF similar to GB/T 33555-2025


Standard similar to GB/T 33555-2025

GB/T 25915.2   GB/T 38800   GB/T 36372   GB/T 36066   

Basic data

Standard ID GB/T 33555-2025 (GB/T33555-2025)
Description (Translated English) Cleanrooms and associated controlled environments - Technical requirements of electrostatic control
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard C70
Classification of International Standard 13.040.35
Word Count Estimation 22,287
Date of Issue 2025-04-25
Date of Implementation 2025-11-01
Older Standard (superseded by this standard) GB/T 33555-2017
Issuing agency(ies) State Administration for Market Regulation, China National Standardization Administration

GB/T 33555-2025: Cleanrooms and associated controlled environments - Technical requirements of electrostatic control


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
ICS 13.040.35 CCSC70 National Standard of the People's Republic of China Replaces GB/T 33555-2017 Cleanrooms and related controlled environments Technical requirements for static control Released on 2025-04-25 2025-11-01 Implementation State Administration for Market Regulation The National Standardization Administration issued

Table of contents

Preface III Introduction IV 1 Scope 1 2 Normative references 1 3 Terms and Definitions 1 4 Sources and hazards of static electricity 3 5 Technical Requirements 4 Appendix A (Informative) Sources and Control Elements of Static Electricity 8 Appendix B (Informative) Technical Measures 10 Appendix C (Informative) Anti-static Floor Type 13 Appendix D (Informative) EPA Classification or Category 14 Appendix E (Informative) Anti-static Equipment and Tools Performance 15 References 16

Foreword

This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part 1.Structure and drafting rules for standardization documents" Drafting. This document replaces GB/T 33555-2017 "Technical Guidelines for Electrostatic Control in Clean Rooms and Related Controlled Environments" and GB/T 33555- Compared with.2017, in addition to structural adjustments and editorial changes, the main technical content changes are as follows. a) The scope of application has been changed (see Chapter 1, Chapter 1 of the.2017 edition); b) Changed the definitions of the terms “static control”, “electrostatic discharge” and “static dissipative material” (see 3.1, 3.4 and 3.13,.2017 edition) 3.4, 3.5 and 3.1); c) Deleted the terms such as electrostatic field (see 3.2, 3.3, 3.6 and 3.7 of the.2017 edition); d) Added the terms “electrostatic discharge sensitive”, “electrostatic attraction”, “anti-static work area”, “electrostatic induction”, “electrostatic charging”, “isolated conductive Definitions of "body", "working surface", "cleanroom suitability", "enclosure", "ionization eliminator" and "equipotential bonding" (see 3.2, 3.3, 3.5, 3.6, 3.7, 3.8, 3.9, 3.10, 3.11, 3.12, 3.14); e) Change “static electricity control” to “static electricity sources and hazards” (see Chapter 4, Chapter 4 of the.2017 edition); f) The relevant contents in “Sources, hazards and monitoring of static electricity” have been changed (see 4.1, 4.2, and 4.1 of the.2017 edition); g) "Control" has been deleted (see 4.2 of the.2017 edition); h) "Control measures" has been deleted (see 4.3 of the.2017 edition); i) Change “training and specifications” to “technical requirements” (see Chapter 5, Chapter 5 of the.2017 edition); j) Change 5.1, 5.2, 5.3, and 5.4 to "General requirements", "Personnel", "Working surfaces", and "Environment and areas" (see 5.1, 5.2, 5.3, 5.4, 5.1, 5.2, 5.3, 5.4 of the.2017 edition); k) Added “equipment and tools”, “ESDS product packaging, transportation and storage”, and “monitoring and testing” (see 5.5, 5.6, and 5.7). Please note that some of the contents of this document may involve patents. The issuing organization of this document does not assume the responsibility for identifying patents. This document was proposed and coordinated by the National Technical Committee for Cleanrooms and Related Controlled Environments (SAC/TC319). This document was drafted by. China Electronics Engineering Design Institute Co., Ltd., MCC Tiangong Group Co., Ltd., Shenzhen Zhongce Metrology and Inspection Co., Ltd. Testing Technology Co., Ltd., Shenzhen Zhongming Technology Co., Ltd., China Association for Standardization, China Power Investment Engineering Research, Testing and Assessment Center Co., Ltd. Company, China Electronics Technology Standardization Institute, Shenzhen Kaishide Technology Co., Ltd., Beijing Oriental Metrology and Testing Institute, China Electronics System Engineering Second Construction Co., Ltd., China Electronics System Engineering Fourth Construction Co., Ltd., Beijing Dyna Experiment Technology Co., Ltd., China Electronic System Engineering Third Construction Co., Ltd., Yaxiang System Integration Technology (Suzhou) Co., Ltd., Xiamen Yongpingtang Building Materials Co., Ltd. Co., Ltd., Beijing Zhongbang Xingye Technology Co., Ltd., Hebei Kehua Antistatic Floor Manufacturing Co., Ltd., Huirui Purification Technology (Jiangsu) Co., Ltd., Bocheng System Technology Co., Ltd., Zhongkai University of Agriculture and Engineering, TCL Huaxing Optoelectronics Technology Co., Ltd., Hefei Jinghe Integrated Circuit Co., Ltd. Co., Ltd. and Changxin Integrated Storage Technology (Beijing) Co., Ltd. The main drafters of this document are. Tan Jun, Wang Tianyi, Yang Guangming, Sun Siyu, Gao Zhiliang, Hao Yinbo, Ma Quanli, Guo Kai, Xu Weiwei, Zhang Zhijian, Ding Lixing, Xi Xiaopeng, Qing Shuping, Xu Jingzhe, Huo Jinpeng, Han Hui, Xiu Dongsheng, Sun Shuo, Han Jingui, Han Lingling, Xiang Wei, Lü Guangshuai, Yang Chupeng, Ye Wei, Zhang Zhiqi, and Huang Jiayang. The previous versions of this document and the documents it replaces are as follows. ---First published in.2017 as GB/T 33555-2017; ---This is the first revision.

Introduction

Static electricity is one of the common sources of pollution in clean rooms and related controlled environments. Static electricity attraction can cause pollutants to accumulate, pollute the clean environment, and affect Affects product quality and personnel health; electrostatic discharge can cause harm to electrostatic sensitive equipment and products in clean environments, and also cause electrical safety and fire protection. Improper static control measures will not only affect the airflow organization and cleanliness of the clean room, but also affect the electrical and Fire safety. This document specifies the static control measures that are consistent with the design and operation characteristics of clean rooms, based on the characteristics of static sources and hazards in clean rooms. Technical requirements to control the effects of static electricity in clean rooms. Cleanrooms and related controlled environments Technical requirements for static control

1 Scope

This document provides the sources and hazards of static electricity in clean rooms and related controlled environments, and specifies the applicable Technical requirements for static control. This document applies to the control of static electricity in cleanrooms and related controlled environments.

2 Normative references

The contents of the following documents constitute essential clauses of this document through normative references in this document. For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies to This document. GB 15982 Hospital Disinfection and Hygiene Standard GB/T 16895.10 Low voltage electrical installations Part 4-44.Safety protection against voltage disturbances and electromagnetic disturbances GB/T 25915.3 Clean rooms and related controlled environments Part 3.Test methods GB/T 25915.4 Clean rooms and related controlled environments Part 4.Design, construction and start-up GB/T 25915.13 Clean rooms and related controlled environments Part 13.Surface cleaning to meet particle and chemical cleanliness requirements GB/T 25915.14 Clean rooms and related controlled environments Part 14.Assessment of equipment suitability based on particle concentration GB/T 25915.15 Clean rooms and related controlled environments Part 15.Assessment of suitability of equipment and materials based on concentration of gaseous chemicals Usability

3 Terms and definitions

The following terms and definitions apply to this document. 3.1 Electrostatic control Activities that control electrostatic effects within permissible limits for a given environment, product or process. 3.2 Susceptible to malfunction or damage due to electrostatic fields or electrostatic discharge. 3.3 The interaction between two or more oppositely charged objects results in an increase in the rate of deposition of particles on the charged surface or in the charging of The movement of particles. 3.4 The rapid transfer of electrostatic charge between objects with different electrostatic potentials due to direct contact or electrostatic field induction.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 33555-2025_English be delivered?

Answer: Upon your order, we will start to translate GB/T 33555-2025_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 33555-2025_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 33555-2025_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 33555-2025?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 33555-2025 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.