HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (29 Sep 2024)

GB/T 33556.1-2017 English PDF

GB/T 33556.1-2017 (GB/T33556.1-2017, GBT 33556.1-2017, GBT33556.1-2017)
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 33556.1-2017English150 Add to Cart 0--9 seconds. Auto-delivery Application specification for hospital cleanrooms and associated controlled environment -- Part 1: General guidelines Valid GB/T 33556.1-2017
Standards related to: GB/T 33556.1-2017

BASIC DATA
Standard ID GB/T 33556.1-2017 (GB/T33556.1-2017)
Description (Translated English) Application specification for hospital cleanrooms and associated controlled environment -- Part 1: General guidelines
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard C70
Classification of International Standard 13.040.20
Word Count Estimation 12,160
Date of Issue 2017-05-12
Date of Implementation 2017-12-01
Quoted Standard GB 15982; GB 19083-2010; GB/T 25915.2-2010; GB/T 25915.3-2010; GB/T 25915.4; GB/T 25916.1; GB/T 25916.2; GB/T 29469-2012; GB 50333-2013; WS/T 368
Drafting Organization Zhongtian Tiancheng (Suzhou) Clean Technology Co., Ltd., Tianjin Longchuan Purification Engineering Co., Ltd., China Standardization Association, PLA General Hospital, Air Force General Hospital, Peking University Third Hospital, Chinese Academy of Medical Sciences Peking Union Medical College Hospital, China Zhongyuan International Engineering Co., Ltd., Lianhe Chengcheng Engineering Co., Ltd., Institute of Health Equipment, Academy of Military Medical Sciences, Beijing Tianzhi Hang Medical Technology Co., Ltd., Shenzhen Lifeng Purification Technology Co., Ltd., Yantai Baoyuan Purification Co., Ltd., Jiangsu Sujing Technology Co., Ltd., Shenzhen Institute of Science and Technology Co., Ltd., Shenzhen City, Granville Medical Systems Engineering Co., Ltd., Beijing Huayang Medical Systems Engineering Co., Ltd., Divine Technology Co., Ltd.
Administrative Organization National Clean Room and Related Controlled Environmental Standardization Technical Committee (SAC/TC 319)
Proposing organization National Clean Room and Related Controlled Environmental Standardization Technical Committee (SAC/TC 319)
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, China National Standardization Administration Committee
Summary This standard specifies the laboratory clean room and related controlled environment validation, operation management and maintenance and other norms. This standard applies to the hospital clean room and related controlled environment, such as clean operating room, hematopoietic stem cell transplantation ward, reproductive center, burn ward, ICU ward, intravenous infusion preparation center.

GB/T 33556.1-2017 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 13.040.20 C 70 Application Specification for Hospital Cleanrooms and Associated Controlled Environment – Part 1. General Guidelines ISSUED ON. MAY 12, 2017 IMPLEMENTED ON. DECEMBER 1, 2017 Issued by. General Administration of Quality Supervision, Inspection and Quarantine; Standardization Administration of PRC. 3. No action is required - Full-copy of this standard will be automatically & immediately delivered to your EMAIL address in 0~60 minutes. Table of Contents Foreword ... 3 Introduction ... 4 1 Scope ... 6 2 Normative References ... 6 3 Terms and Definitions ... 7 4 Requirements ... 8 Appendix A (Informative) Intelligent Monitoring System for Hospital Controlled Environment Data ... 14 Appendix B (Informative) Comparison List of Various Classifications of Cleanliness ... 15 Bibliography ... 16 Foreword GB/T 33556 Application Specification for Hospital Cleanrooms and Associated Controlled Environment can be divided into the following 4 parts. --- Part 1. General Guidelines; --- Part 2. Operating Room, Hematopoietic Stem Cell Transplantation Room, Burn Ward, etc.; --- Part 3. Reproduction Center, Cell Therapy and the Like Micro Operation Environment; --- Part 4. Others. This Part belongs to Part 1 of GB/T 33556. This Part was drafted as per the rules specified in GB/T 1.1-2009. This Part was proposed by and under the jurisdiction of National Technical Committee for Standardization of Cleanrooms and Associated Controlled Environment. Drafting organizations of this Part. Success Way Clean Technology Co., Ltd., Tianjin Longchuan Purifying Engineering Co., Ltd., China Association for Standardization, PLA General Hospital, Air Force General Hospital, Peking University Third Hospital, Peking Union Medical College Hospital of Chinese Academy of Medical Science, China IPPR International Engineering Co., Ltd., Alliance Contracting Co., Ltd., Institute of Medical Equipment Academy of Military Medical Science, TINAVI Medical Technologies Co., Ltd., Shenzhen Lifeng Cleanroom Technologies Co., Ltd., YANTAIR Co., Ltd., Jiangsu Suzhou Purification Science and Technology Co., Ltd., Research Institute of Chemical Defense, Guangzhou Clima Air Purity Equipment Co., Ltd., Shenzhen Jilong Contamination Control Technology Co., Ltd., Beijing North Tianyu Architectural Decoration Co., Ltd., Wuxi Hanjia Medical Science & Technology Co., Ltd., Shenzhen Weida Medical System Engineering Co., Ltd., and Beijing Huayee Shenzhou Technology Co., Ltd. Chief drafting staffs of this Part. Yang Ziqiang, Cao Jingui, Yin Xiaodong, Xu Huoju, Jiang Weikang, Zhang Lihai, Zhao Ameng, Huang Jihui, Yu Ziqiang, Tu You, Lin Xiangyang, He Li, Guo Li, Zhou Hengjin, Ma Dong, Li Zhiping, Yang Xiaobing, Chen Hanqing, Zhang Xiaodong, Bing Shaotong, Pan Xuegang, Jiang Haoxia, Tong Guangcai, and Hou Bin. Introduction Hospital cleanroom is one of the auxiliary measures to control the hospital infection. In 1961, Sir John Charnley (1911-1982) known as “Father of Hip Arthroplasty” in the British Wrightington Hospital pioneered to, by cleaning the air method, improve the operating room environment; so that reduce surgical infection. However, the literature on relationship between air environment and surgical infection rate that had the clinical significance of medical statistics and was widely cited was published by LidewellOM et al. in 1987, the title of such literature is of “Multiple Studies on Ultra Clean Air and Antibiotics Used to Prevent Postoperative Infection in 8052 Cases of Joint Replacement Surgery”; such study recognized, to a certain extent, the role of ultra clean air. Internationally, for the role of the hospital cleanroom and associated controlled environment in reducing the rate of infection, the medical field and engineering personnel in the cleanroom and associated controlled environment had their own opinions. The medical field has long been skeptical about the effectiveness of clean operating room. In recent year, the international medical field proposed more specific doubts on the laminar flow clean operating room based on statistical analysis on a large number of clinical case practice. The introduction of the Russian Federation Standard GOSTR 52539-2006 General Requirements for Air Cleanliness in Hospital prepared by Russian Association of Micro-Contamination Control Engineers clearly states that the cleanroom ventilation, air conditioning system and equipment can’t replace the traditional hospital bacterial control measures, but can only supplement it. Human’s cognition on medical infection is still in the process of exploration. In the air attached to the dust of microorganisms (In the relevant information at home and abroad, the literature has not been found on the exact relationship between the number of dust and microorganisms. Obviously, animals and plants are more likely to scatter off the fine dust containing microorganisms, such as pollen, body debris, etc.) have been recognized at home and abroad one of the objects of prevention; while purifying the air in the medical space has become one of the measures to prevent the medical infection. China’s national serial standards of GB/T 25915 Cleanrooms and Associated Controlled Environment equivalently adopting ISO 14644 internals serial standards drew lessons on the international counterparts’ systematic concepts in each links such as test, design, construction, start operation, etc. To give full play to the role of the hospital cleanroom, and meet the use requirements, every detail in the operation can’t be ignored. The energy consumption for the air conditioning system and ventilation in the hospital cleanroom and associated controlled environment is about 5tims ~ 10times of that in the high-grade hotel with the same area. Reasonably determining the matching among Application Specification for Hospital Cleanrooms and Associated Controlled Environment – Part 1. General Guidelines 1 Scope This Part of GB/T 33556 specifies the specifications on the verification, operation management, maintenance, and etc. of hospital cleanroom and associated controlled environment. This Part is applicable to the hospital cleanroom and associated controlled environment like clean operating room, hematopoietic stem cell transplantation room, reproduction center, burn ward, ICU ward, intravenous infusion preparation center. 2 Normative References The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) are applicable to this document. GB 15982 Hygienic Standard for Disinfection in Hospitals GB 19083-2010 Technical Requirements for Protective Face Mask for Medical Use GB/T 25915.2-2010 Cleanrooms and Associated Controlled Environments – Part 2. Specifications for Testing and Monitoring to Prove Continued Compliance with GB/T 25915.1 GB/T 25915.3-2010 Cleanrooms and Associated Controlled Environments – Part 3. Test Methods GB/T 25915.4 Cleanrooms and Associated Controlled Environments – Part 4. Design, Construction and Start-Up GB/T 25916.1 Cleanrooms and Associated Controlled Environments – Biocontamination Control – Part 1. General Principles and Methods [GB 50333-2013, definition 2.0.13] 3.6 Operational Facilities are operated in the specified state; there is specified personnel present; and work in an agreed state. 3.7 Installation acceptance inspection Facilities have been built; under the as-built condition, confirm whether the performance parameters of facilities in the cleanroom and associated controlled environment meet the requirements of design. 3.8 Function acceptance inspection Under the at-rest condition, confirm whether the performance of facilities in the cleanroom and associated controlled environment satisfies (continues to meet) the requirements of design. 3.9 Operational evaluation Under the specified operational condition, conform the compliance of performance parameters of facilities in cleanroom and associated controlled environment. 4 Requirements 4.1 Assessment, acceptance and operational evaluation 4.1.1 Assessment 4.1.1.1 When designing new hospital buildings of cleanroom and associated controlled environment, it shall be performed after assessing the rationality of controlled environment, overall layout, etc. 4.1.1.2 Before constructing the cleanroom and associated controlled environment within the existing building, assess the rationality of the following items like controlled environment function, requirements, classification of cleanliness, overall layout, indoor... ...