HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

GB/T 30940-2014 English PDF

US$229.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 30940-2014: Determination of tretinoin and isotretinoin in cosmetics -- High performance liquid chromatography
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 30940-2014English229 Add to Cart 3 days [Need to translate] Determination of tretinoin and isotretinoin in cosmetics -- High performance liquid chromatography Valid GB/T 30940-2014

PDF similar to GB/T 30940-2014


Standard similar to GB/T 30940-2014

GB/T 29679   GB/T 29665   GB/T 29680   GB/T 30931   GB/T 30932   GB/T 30930   

Basic data

Standard ID GB/T 30940-2014 (GB/T30940-2014)
Description (Translated English) Determination of tretinoin and isotretinoin in cosmetics -- High performance liquid chromatography
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard Y42
Classification of International Standard 71.100.70
Word Count Estimation 10,194
Date of Issue 7/8/2014
Date of Implementation 11/1/2014
Quoted Standard GB/T 6682
Regulation (derived from) 2014 National Standards Bulletin No. 18
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard specifies the method of liquid chromatography cosmetics retinoic acid and isotretinoin. This standard applies to the determination of skin care cosmetics category in retinoic acid and isotretinoin. The standard for Accutane and isotretinoin

GB/T 30940-2014: Determination of tretinoin and isotretinoin in cosmetics -- High performance liquid chromatography


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Determination of tretinoin and isotretinoin in cosmetics - High performance liquid chromatography ICS 71.100.70 Y42 National Standards of People's Republic of China Retinoic acid, banned substances in cosmetics, Determination of isotretinoin. High performance liquid chromatography Released on.2014-07-08 2014-11-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China Issued by the National Standardization Administration of China Retinoic acid, banned substances in cosmetics, Determination of isotretinoin. High performance liquid chromatography

1 Scope

This standard specifies the method for the determination of retinoic acid and isotretinoin in cosmetics by liquid chromatography. This standard applies to the determination of retinoic acid and isotretinoin in skin care cosmetics. The detection limit of this standard for retinoic acid and isotretinoin is 1.0 mg/kg, and the limit of quantification is 3.0 mg/kg.

2 Normative references

The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this article Pieces. For undated reference documents, the latest version (including all amendments) is applicable to this document. GB/T 6682 Analytical laboratory water specifications and test methods

3 Method summary

Using methanol as solvent, ultrasonic extraction, centrifugation, 0.45μm organic filter membrane filtration, liquid chromatography detection, external standard method for quantification.

4 Reagents and materials

Unless otherwise specified, the reagents used are of analytical grade, and the water is the first grade water specified in GB/T 6682. 4.1 Methanol. chromatographically pure. 4.2 Glacial acetic acid. 4.3 Dichloromethane. 4.4 Standard stock solution of retinoic acid. accurately weigh 0.01g of retinoic acid, accurate to 0.0001g, and add an appropriate amount of retinoic acid to a 50mL brown volumetric flask. The alcohol was dissolved by ultrasonic, and the volume was adjusted to the mark with methanol to obtain a standard stock solution with a concentration of retinoic acid solution of.200 mg/L. Refrigerator protects from light Save it and use it for 2 months. 4.5 Isotretinoin standard stock solution. accurately weigh 0.01g isotretinoin, accurate to 0.0001g, and place it in a 50mL brown volumetric flask. Dissolve the volume of methanol ultrasonically, and dilute to volume with methanol to obtain a standard stock solution with a concentration of.200 mg/L of isotretinoin solution. Refrigerator to avoid light and cold It can be used for 2 months in storage. 4.6 Standard working solution. Pipette the above two standard stock solutions (4.4) and (4.5) respectively, and use methanol to make 0.15mg/L~50.0mg/L The mixed standard working solution is ready to use. 4.7 The CAS number, molecular formula, relative molecular mass and structural formula of retinoic acid and isotretinoin are shown in Table A.1 of Appendix A.

5 Apparatus and equipment

5.1 Analytical balance. Sensitivity 0.0001g. 5.2 High performance liquid chromatograph with diode array detector. 5.3 Ultrasonic cleaner. 5.4 Centrifuge. 5.5 Graduated centrifuge tube. 10mL.

6 Analysis steps

6.1 Sample preparation Weigh 0.5g of cosmetic sample (accurate to 0.001g) into a 10mL graduated test tube, add methanol and dilute to the mark, vortex and shake Swing until the sample is evenly dispersed, ultrasonically extract for 10min, 6500r/min, centrifuge for 10min, filter the supernatant through a 0.45μm filter membrane, and filter the filtrate To be tested. 6.2 Determination 6.2.1 Reference conditions for liquid chromatography The reference conditions for liquid chromatography determination are as follows. a) Chromatographic column type. C18 column (250mm×4.6mm particle size. 5μm); or chromatographic column with equivalent performance; b) Sample injection volume. 10μL; c) Mobile phase. A. 0.5% glacial acetic acid methanol solution (5mL glacial acetic acid added to 1000mL methanol); B. 0.5% glacial acetic acid aqueous solution (Add 5mL glacial acetic acid to 1000mL water); d) Mobile phase flow rate. 1.0mL/min; e) Measurement wavelength. 358nm; f) See Table 1 for gradient elution conditions. Table 1 Gradient elution conditions 6.2.2 Determination Use the prepared standard working solution (4.6) to draw a standard working curve, and use the standard working curve to quantify the sample, which exceeds the linear range Then it should be diluted and then injected for analysis. Refer to Figure B.1 and Figure B.2 in Appendix B for the chromatogram and spectrum of the reference material.

7 Result calculation

The content of the component to be tested in the sample is calculated according to formula (1).

8 Limit of detection and limit of quantification

The detection limit of this standard for retinoic acid and isotretinoin is 1.0 mg/kg, and the limit of quantification is 3.0 mg/kg.

9 Recovery rate and precision

The additive concentration is in the range of 3mg/kg~1000mg/kg, the recovery rate of addition is between 90%~105%, and the relative standard deviation is small Less than 10%. 10 allowable difference The absolute difference between two independent determination results obtained under repeated conditions shall not exceed 10% of the arithmetic mean.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 30940-2014_English be delivered?

Answer: Upon your order, we will start to translate GB/T 30940-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 30940-2014_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 30940-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.