HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (6 Jul 2025)

GB/T 30120-2013 English PDF

US$594.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 30120-2013: Temperature -- Electromotive force (EMF) tables for pure-element thermocouple combinations
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 30120-2013English594 Add to Cart 3 days [Need to translate] Temperature -- Electromotive force (EMF) tables for pure-element thermocouple combinations Valid GB/T 30120-2013

PDF Samples

Basic data

Standard ID GB/T 30120-2013 (GB/T30120-2013)
Description (Translated English) Temperature. Electromotive force (EMF) tables for pure-element thermocouple combinations
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard N11
Classification of International Standard 17.200.20
Word Count Estimation 30,327
Quoted Standard IEC 60584-1
Adopted Standard IEC 62460-2008, IDT
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard specifies the gold - platinum thermocouples and platinum - palladium thermocouple temperature - electromotive force (EMF) and EMF - Temperature indexing table and functional relationship. Meanwhile, in order to facilitate the use of this sta

Similar standards

GB/T 20730.2   GB/T 19146   GB/T 22065   GB/T 45358   GB/T 19665   GB/T 30121   

GB/T 30120-2013: Temperature -- Electromotive force (EMF) tables for pure-element thermocouple combinations


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Temperature. Electromotive force (EMF) tables for pure-element thermocouple combinations ICS 17.200.20 N11 National Standards of People's Republic of China Pure metallic composition thermocouple indexing table Temperature-Electromotiveforce (EMF) tablesfor (IEC 62460.2008, IDT) Issued on. 2013-12-17 2014-06-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Preface Ⅰ 1 Scope 1 2 Normative references 1 3 Terms and definitions 4 indexing table and function of Formula 1 5 gold - platinum thermocouple indexing table 2 5.1 gold - platinum thermocouple. EMF - temperature relationship at intervals of 1 ℃ 2 5.2 gold - platinum thermocouple. Temperature - electromotive force relationship at intervals of 10μV 5 5.3 gold - platinum thermocouple ITS-90 defines a fixed point thermoelectric value (informative) 10 6 platinum - palladium thermocouple indexing table 11 6.1 platinum - palladium thermocouple. EMF - temperature relationship at intervals of 1 ℃ 11 6.2 platinum - palladium thermocouple. Temperature - electromotive force relationship intervals 10μV 15 6.3 platinum - palladium thermocouple thermoelectric value in ITS-90 defines a fixed point (informative) 22 Appendix A (normative) gold - platinum thermocouple 23 coefficient indexing function Appendix B (normative) platinum - palladium thermocouple indexing function coefficients 24 Annex C (informative) gold - platinum thermocouple approximate inverse function of the coefficient of 25 Annex D (informative) platinum - palladium thermocouple approximate inverse function of the coefficient of 26

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules. This standard uses the translation method identical with IEC 62460.2008 "Pure metallic composition thermocouple indexing table." Correspondence between the consistency of the standards of international documents and normative references of the following documents. --- GB/T 16839.1-1997 Thermocouples - Part 1. indexing table (IEC 60584-1.1995, IDT). Given IEC 62460.2008 Annex A and Annex B contain the normative content of "coefficient indexing function" and informative content "Approximate inverse function of the factor" of this standard, the following editorial changes made. --- Original IEC 62460.2008 Annex A "gold - platinum thermocouple coefficient" split Appendix A (normative) "gold - platinum thermoelectric Even coefficient indexing function "and Appendix C (informative)" gold - platinum thermocouple approximate inverse function of the factor "; --- Original IEC 62460.2008 Appendix B "platinum - palladium thermocouple coefficient" split Appendix B (normative) "Platinum - Palladium Thermoelectric Even coefficient indexing function "and Appendix D (informative)" platinum - palladium thermocouple approximate inverse function of the factor "; --- Appendix C, corresponding to 1000 ℃ electromotive force by the 17085μV modify 17085.3μV, and indexing table and Appendix A Paul Hold the same; --- Appendix B and Appendix D, corresponding to 1500 ℃ electromotive force by the 22932μV to 22931.7μV, keep up with the indexing table Consistent. The standard proposed by China Machinery Industry Federation. This standard by the national industrial process measurement and control Standardization Technical Committee (SAC/TC124) centralized. This standard was drafted. Shanghai Industrial Automation Instrument Research Institute, Anhui days and Culture Co., Ltd., Chongqing City is the temperature Instrument Co., the company. The main drafters of this standard. Wang Jun, Wang Jianing, Liuren Cong, Zhou Yu step. Pure metallic composition thermocouple indexing table

1 Scope

This standard specifies the gold - platinum thermocouples and platinum - palladium thermocouple temperature - electromotive force (EMF) and emf - temperature and as a function of the indexing table formula. Meanwhile, in order to facilitate the use of this standard also provides a temperature - electromotive force as a function of the approximate function. This standard specifies the form and function of the indexing formula for using the percentage by weight of not less than 99.999% purity of gold, platinum and purity of not 99.99% less than the gold-palladium composition - platinum thermocouples and platinum - palladium thermocouple. The standard does not specify thermocouple emf - temperature tolerance initial values. If desired, the allowance should be made thermocouple wire manufacturers and users Association Suppliers OK. The temperature used in this standard based on the 1990 International Temperature Scale (ITS-90), in degrees Celsius, symbol t90/℃. Electromotive force (EMF) in microvolts, symbol E/μV. This standard does not relate to a combination of pure metals and extend the thermocouple wire compensation. Their use is determined by the manufacturer of the problem in consultation with users.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. IEC 60584-1 Thermocouples Part 1. indexing table (Thermocouples-Part 1. Referencetables)

3 Terms and Definitions

The following terms and definitions apply to this document. 3.1 Thermocouple type thermocoupletypes This standard covers the following types of thermocouple wire. King - platinum (Au/Pt, Au/Pt); · Platinum - palladium (Pt/Pd, Pt/Pd). When identifying thermocouple, according to international practices (such as IEC 60584-1 requirements) will be placed in front of the cathode. 3.2 ITS-90 defines a fixed point thermoelectric value thermoelectricvaluesattheITS-90fixedpoints Triple Point is defined in the corresponding indexing table temperature range (TP), the value of the melting point (MP) and freezing point (FP) of. S is the Seebeck coefficient temperature The first derivative of electromotive force - degrees. Note. The Seebeck coefficient is small Seebeck potential change caused by the temperature difference between the rate of change of the Seebeck coefficient in units of microvolts per degree Celsius, symbol S / (ΜV/℃).

4 indexing table and functional

This standard includes the following indexing table. King - Platinum Thermocouple. EMF - temperature relationship at intervals of 1 ℃;
......