Path: Home > GB/T > Page269 > GB/T 24623-2009 Home > Standard_List > GB/T > Page269 > GB/T 24623-2009
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 24623-2009 | English | 279 |
Add to Cart
|
3 days [Need to translate]
|
Radio interference test on high-voltage insulators
| Valid |
GB/T 24623-2009
|
PDF similar to GB/T 24623-2009
Basic data | Standard ID | GB/T 24623-2009 (GB/T24623-2009) | | Description (Translated English) | Radio interference test on high-voltage insulators | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | K48 | | Classification of International Standard | 29.080.10 | | Word Count Estimation | 12,165 | | Date of Issue | 2009-11-30 | | Date of Implementation | 2010-04-01 | | Quoted Standard | GB/T 1001.1-2003; GB/T 4109-2008; GB/T 6113.101-2008; GB/T 8287.1-2008; GB/T 16927.1-1997; IEC 60383-2-1993; CISPR 18-2-1986; GB/T 2900.8 | | Adopted Standard | IEC 60437-1997, MOD | | Regulation (derived from) | Announcement of Newly Approved National Standards No. 13 of 2009 (No. 153 overall) | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the insulator in a clean, dry laboratory on Radio Interference (RI) test procedures, measurement frequency is 0. 5MHz or 1MHz, or 0. 5MHz ~ 2MHz within a certain frequency. Operation, the insulator element radio interference characteristics may be due to environmental conditions, particularly humidity and contamination rainfall and other conditions vary. Taking into account the range of environmental conditions simulated rain reproducible test conditions specified is not feasible, therefore, the standard only provides a clean and dry insulators tests. |
GB/T 24623-2009: Radio interference test on high-voltage insulators---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Radio interference test on high-voltage insulators
ICS 29.080.10
K48
National Standards of People's Republic of China
Radio interference test high-voltage insulators
(IEC 60437.1997, MOD)
Posted 2009-11-30
2010-04-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Preface Ⅰ
1 Scope 1
2 Normative references 1
3 Terms and definitions
4 Measurement frequency 1
5 radio noise limits and test voltage 1
Measuring instruments 2 6
7 measuring circuit 2
8 Test voltage requirements 3
9 3 atmospheric conditions
3 10 test sites
11 test insulator arrangement 4
12 Type test insulators 4
13 Type 5 test procedure
14 Sampling Test Procedure 7
7 15 test reports
Foreword
This revised standard adopts IEC 60437.1997 "high-voltage insulators radio interference test" (in English).
This standard and IEC 60437.1997 as compared to made the following modifications, modifications at a single vertical line (|) in which they are involved reg page
Margin identified.
--- Because this standard is the national standard itself, delete the first four chapters of radio disturbance tests for measuring frequency insulator about the world
Rate Description Note;
--- For ease of use, the CISPR18-2. 1986 test circuit and the test loop checking and calibration procedures included in this standard,
Technical remain unchanged. Thus increasing the FIGS. 1 to 4 in Chapter 7, the column at 13.1 points 13.1.1 and 13.1.2
Two;
--- Cited international standards of our standards.
For ease of use, this standard also made the following editorial changes.
a) instead of as a decimal by decimal comma ",". ",";
b) "this International Standard" be replaced by "this standard";
c) Remove IEC 60437.1997 Foreword.
Except in 13.1.1 and 13.1.2 13.1 added the two, the present standard and IEC 60437.1997 is identical number of clauses.
The standard proposed by China Electrical Equipment Industrial Association.
This standard by the National Standardization Technical Committee Insulators (SAC/TC80) centralized.
This standard was drafted. National Insulator arrester Quality Supervision and Inspection Center, Xi'an High Voltage Apparatus Research Institute Co., Ltd., State Grid
Wuhan High Voltage Research Institute, China Electric Power Research Institute, New Northeast Electric (Shenyang) High Voltage Switchgear Co., Ltd. in Shaanxi Province power company.
The main drafters of this standard. Peng Wei, Yao Junrui, Zhang Rui, TRANSACTIONS OF THE Liu Zhiqiang, Zhang Shu, Yuntao.
Radio interference test high-voltage insulators
1 Scope
This standard specifies the laboratory radio interference (RI) test program on a clean and dry insulators, the measurement frequency of 0.5MHz
Or 1MHz, or 0.5MHz ~ 2MHz within a certain frequency range.
Operation, radio interference characteristics of insulators may be due to environmental conditions, particularly rainfall and other moisture and contamination situation different
Variety. Taking into account the environmental conditions to simulate changes in the scope of the provisions of reproducible test conditions is not feasible, therefore, the only provision in the standard
Test on a clean, dry insulator.
Note. The impacts include contamination state, including the state of the surface of the insulator in CISPR18-2 Amendment 1 below.
2 Normative references
Price & DeliveryUS$279.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 24623-2009: Radio interference test on high-voltage insulators Status: Valid
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 24623-2009_English be delivered?Answer: Upon your order, we will start to translate GB/T 24623-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 24623-2009_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 24623-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|