US$799.00 · In stock Delivery: <= 6 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 23752-2009: Hollow pressurized and unpressurized ceramic and glass insulators for use in electrical equipment with rated voltages greater than 1 000 V Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GB/T 23752-2009 | English | 799 |
Add to Cart
|
6 days [Need to translate]
|
Hollow pressurized and unpressurized ceramic and glass insulators for use in electrical equipment with rated voltages greater than 1 000 V
| Valid |
GB/T 23752-2009
|
PDF similar to GB/T 23752-2009
Basic data Standard ID | GB/T 23752-2009 (GB/T23752-2009) | Description (Translated English) | Hollow pressurized and unpressurized ceramic and glass insulators for use in electrical equipment with rated voltages greater than 1 000 V | Sector / Industry | National Standard (Recommended) | Classification of Chinese Standard | K48 | Classification of International Standard | 29.080.10 | Word Count Estimation | 36,381 | Date of Issue | 2009-05-06 | Date of Implementation | 2009-11-01 | Adopted Standard | IEC 62155-2003, MOD | Regulation (derived from) | Announcement of Newly Approved National Standards No. 6, 2009 (No. 146 overall) | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | Summary | This standard provides a self- starter and efficient three-phase permanent magnet synchronous motor type, the basic parameters and dimensions, technical requirements, inspection rules, packaging, marking and warranty requirements. This standard applies to self- starters and efficient three-phase permanent magnet synchronous motor (frame size 132 to 280) (hereinafter referred to as the motor). This standard specifies an efficient three-phase permanent magnet synchronous motor for oil beam pumping unit and similar high starting torque load, number of poles is 6 pole, 8 -pole, with cage rotor starting winding. This standard does not include permanent magnet synchronous AC servo motors. |
GB/T 23752-2009: Hollow pressurized and unpressurized ceramic and glass insulators for use in electrical equipment with rated voltages greater than 1 000 V ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Hollow pressurized and unpressurized ceramic and glass insulators for use in electrical equipment with rated voltages greater than 1 000 V
ICS 29.080.10
K48
National Standards of People's Republic of China
1000 Vp higher than the rated voltage electrical equipment under pressure
And non-pressure hollow porcelain and glass insulators
(IEC 62155.2003, MOD)
Posted 2009-05-06
2009-11-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Preface Ⅰ
1 Scope and purpose 1
2 Normative references 2
3 Terms and definitions 2
4 Insulation material 4
5 Top 5 general design
6 Test classification, sampling rules and procedures 6
7 General test procedures and requirements 9
8 Type tests 17
9 sampling test 18
10-by-18 test
Documentation 11 21
Appendix A (informative) parallel hollow insulators or hollow insulating member, concentricity, eccentricity, angle of the upper and lower mounting holes
Deviation, straightness and inclination umbrella Test Method 22
Annex B (informative) Test method for bending hollow insulating member 26
Annex C (informative) Temperature cycle test alternative methods 28
Equivalent moment Appendix D (informative) design pressure of 29
Annex E (informative) This standard and IEC 62155.2003 technical differences and their causes 30
Annex F (informative) This standard and IEC 62155.2003 reg control number 31
Foreword
This revised standard adopts IEC 62155.2003 "rated voltages higher than 1000V electrical equipment with pressurized and non-pressurized hollow porcelain and glass
Glass insulator "(in English).
This standard and IEC 62155.2003 as compared to doing some technical modifications, modifications at a single vertical line (|) in Chapter they involved
Identification of the margin and added to Appendix E to illustrate these changes and their causes.
For ease of use, this standard made the following editorial changes.
"." --- With a decimal point instead of a comma as the decimal point, "";
--- Remove IEC 62155.2003 Foreword;
--- "This International Standard" be replaced by "this standard";
--- Canceled IEC 62155.2003 bibliography.
The Rules for drafting standards by GB/T 1.1-2000, text structure and IEC 62155.2003 are identical.
Appendix F gives this standard and IEC 62155.2003 clauses table.
The Standard Appendix A, Appendix B, Appendix C, Appendix D, Appendix E and F are informative appendices.
The standard proposed by China Electrical Equipment Industrial Association.
This standard by the National Standardization Technical Committee Insulators (SAC/TC80) centralized.
This standard is mainly drafted by. Xi'an Institute of Electric Porcelain Co., Ltd., West An Shuangjia high-voltage ceramic Electric Co., Ltd., Hunan Liling Huaxin
Porcelain Electric Co., the National Insulator arrester Quality Supervision and Inspection Center, Xi'an High Voltage Apparatus Research Institute Co., Ltd., Chongqing
School, New Northeast Electric (Shenyang) High Voltage Switchgear Co., Ltd., Nanjing Electric (Group) Co., Ltd.
The main drafters of this standard. Zhao Hui, Yao Junrui, Ych-Er Chen, Shi Junsheng, Peng Wei, Hu Wenqi, tour Yimin, Shuli Chun, Zhang Shu, Chen Yuting,
Gurui Yun.
This standard was first formulated.
1000 Vp higher than the rated voltage electrical equipment under pressure
And non-pressure hollow porcelain and glass insulators
1 Scope and purpose
1.1 General
This standard applies to.
--- Electrical equipment in general-purpose hollow porcelain and glass insulators;
--- Switch and gas pressure control equipment and long-term bear hollow porcelain insulators.
These insulators for AC rated voltage less than 1000V, frequency no greater than 100Hz or DC rated voltage not less than 1500V
Indoor and outdoor electrical equipment.
Hollow insulators suitable electrical equipment for example as follows.
---breaker;
--- Isolation switch;
--- Load switch;
--- Grounding switch;
--- Transformers;
---lightning arrester;
---casing;
--- Cable terminal;
--- Capacitors.
This standard does not specify electrical type tests, it is because a part of the insulator is composed of electrical equipment, withstand voltage is not absolutely hollow
Edge sub own characteristics, but the characteristics of the device.
1.2 general-purpose hollow insulators or hollow insulating member
Hollow glass or porcelain insulators or insulating parts applicable to.
--- Not under pressure;
--- Long withstand internal pressure ≤50kPa (gauge pressure);
--- Long withstand internal gas pressure> 50kPa (gauge pressure), but the lumen volume < 1L (1000cm3);
--- Long withstand the internal pressure of the liquid.
The purpose of this standard are.
--- Definitions of the terms used;
--- Define hollow insulators and mechanical and dimensional characteristics of the hollow insulating member;
--- Define the hollow insulator wall electric strength;
--- Define the characteristic values \u200b\u200bspecified test conditions;
--- Specified test methods;
--- Specified acceptance criteria.
1.3 long withstand the gas pressure within the hollow porcelain insulators
Hollow porcelain insulators or insulating parts long withstand the internal gas pressure, and with the end fitting, long-term internal gas pressure > 50kPa (Table
Pressure), while the cavity volume ≥1L (1000cm3).
NOTE. The gas may be dry air, an inert gas such as nitrogen or sulfur hexafluoride gas, or a mixture of such gases.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 23752-2009_English be delivered?Answer: Upon your order, we will start to translate GB/T 23752-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 6 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 23752-2009_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 23752-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|