US$349.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 16818-2008: Specifications for short to medium ranges electro-optical distance measurements Status: Valid GB/T 16818: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 16818-2008 | English | 349 |
Add to Cart
|
3 days [Need to translate]
|
Specifications for short to medium ranges electro-optical distance measurements
| Valid |
GB/T 16818-2008
|
| GB/T 16818-1997 | English | 839 |
Add to Cart
|
6 days [Need to translate]
|
Specification for short to medium ranges electro-optical distance measurements
| Obsolete |
GB/T 16818-1997
|
PDF similar to GB/T 16818-2008
Basic data | Standard ID | GB/T 16818-2008 (GB/T16818-2008) | | Description (Translated English) | Specifications for short to medium ranges electro-optical distance measurements | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | A76 | | Classification of International Standard | 07.040 | | Word Count Estimation | 15,164 | | Date of Issue | 2008-06-20 | | Date of Implementation | 2008-12-01 | | Older Standard (superseded by this standard) | GB/T 16818-1997 | | Quoted Standard | JJG 703; JJG 414; JJG 100; CH 1002; CH 1003; CH/T 2004 | | Regulation (derived from) | Announcement of Newly Approved National Standards No. 11 of 2008 (No. 124 overall) | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the use of measurement range is less than 15km geodimeter (including total station) in progress, the level of short-range distance measurement and accuracy requirements, technical approach, workflow and distance calculations. This standard applies to control surveying, topographic surveying, engineering surveying and other measurements in the job, the short-range optical distance. |
GB/T 16818-2008: Specifications for short to medium ranges electro-optical distance measurements---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Specifications for short to medium ranges electro-optical distance measurements
ICS 07.040
A76
National Standards of People's Republic of China
Replacing GB/T 16818-1997
The short-range optical distance specifications
Posted 2008-06-20
2008-12-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Preface Ⅰ
1 Scope 1
2 Normative references 1
3 Symbol 1
4 Basic requirements 1
5 distance measurement 2
6 distance calculation 6
Consolidation and turned over 117 ranging information
8 rangefinder maintenance and repair 11
Foreword
This standard replaces GB/T 16818-1997. This standard compared with GB/T 16818-1997, major changes include.
--- According to GB/T 1.1-2000 "Standardization Guide Part 1. Standard structure and write rules" of the original standard grid
The formula has been modified;
--- Modification and adjustment of the "four basic requirements";
--- Deletion of the requirement of point;
--- Modify the documentation requirements;
--- Modify the outcome of the consolidation and turned over the contents;
--- Deleted Appendix A, Appendix B, Appendix C, Appendix D, Appendix E, Appendix F.
This standard was proposed by the State Bureau of Surveying and Mapping.
This standard by the National Standardization Technical Committee on Geographical Information.
This standard was drafted. National Mapping Bureau of Surveying and Mapping Standardization Institute.
The main drafters of this standard. Shaw school year, Zhu Jian, Rendao Sheng.
This standard replaces the standards previously issued as follows.
--- ZBA76002-1987;
--- GB/T 16818-1997.
The short-range optical distance specifications
1 Scope
This standard specifies the use of the measuring range is within 15km of EDM (including total station) in progress, and the level of short distance measurement
Accuracy requirements, technical methods, workflow and distance calculation method.
This standard applies to control survey, topographic survey, engineering survey and other measurement operations, the short-range optical distance.
2 Normative references
Following standard terms of this standard reference and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
JJG703 geodimeter
JJG414 theodolite
JJG100 total station electronic speed measuring instrument
CH1002 mapping products for inspection, acceptance
CH1003 Plotting Product Quality Standards
CH/T 2004 measurements outside the industry, the basic provisions of electronic records
3 Symbol
Symbols used in this standard as follows.
D '--- observation distance in meters (m);
D --- by measuring the corrected slope distance in meters (m);
D0 --- straight chord length in meters (m);
D1 --- horizontal distance or the reference ellipsoid of the chord length, in meters (m);
D2 --- horizontal distance or reference ellipsoid arc length in meters (m);
H1, H2 --- measuring point reference ellipsoid height in meters (m); ellipsoid elevation in place of normal height;
K --- refraction coefficient (≈0.13);
4 Basic requirements
4.1 EDM (hereinafter referred to as DME) divided by the measurement range, a short distance rangefinder. Odometry 3km within a short distance of the
Instrument, measuring range 3km ~ 15km of medium-range finder, measuring range is more than 15km distance rangefinder. Press rangefinder factory standard differential is nominal,
Imputed to 1km ranging standard deviation calculation accuracy divided into four levels (see Table 1).
Table 1 Scopefinder accuracy rating
Ranging accuracy class standard deviation
NOTE. D is the distance measurement unit in kilometers (km).
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 16818-2008_English be delivered?Answer: Upon your order, we will start to translate GB/T 16818-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 16818-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 16818-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 16818-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 16818-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|