US$509.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 13034-2008: Insulated pulleys for live working Status: Valid GB/T 13034: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 13034-2008 | English | 509 |
Add to Cart
|
4 days [Need to translate]
|
Insulated pulleys for live working
| Valid |
GB/T 13034-2008
|
| GB/T 13034-2003 | English | 879 |
Add to Cart
|
6 days [Need to translate]
|
Live working insulation tackle
| Obsolete |
GB/T 13034-2003
|
| GB 13034-1991 | English | 759 |
Add to Cart
|
5 days [Need to translate]
|
Insulated pulleys for live working
| Obsolete |
GB 13034-1991
|
PDF similar to GB/T 13034-2008
Basic data | Standard ID | GB/T 13034-2008 (GB/T13034-2008) | | Description (Translated English) | Insulated pulleys for live working | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | K47 | | Classification of International Standard | 13.260 | | Word Count Estimation | 22,235 | | Date of Issue | 2008-09-24 | | Date of Implementation | 2009-08-01 | | Older Standard (superseded by this standard) | GB/T 13034-2003 | | Quoted Standard | GB/T 1303.1; GB/T 6179; GB/T 6181; GB/T 16927.1; HG/T 2349 | | Regulation (derived from) | Announcement of Newly Approved National Standards No. 16 of 2008 (No. 129 overall) | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the pulley live working insulation requirements, test methods, inspection rules and markings. This standard applies to the high-voltage electrical equipment used in live working on the insulation tackle. |
GB/T 13034-2008: Insulated pulleys for live working---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Insulated pulleys for live working
ICS 13.260
K47
National Standards of People's Republic of China
Replacing GB/T 13034-2003
Live working with insulating block
Posted 2008-09-24
2009-08-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Preface Ⅰ
1 Scope 1
2 Normative references 1
3 Requirements 1
4 Test Method 3
5 3 Classification and Marking
14 6 Inspection Rules
7 signs, packaging and storage 14
Appendix A (normative) Test and test pulley arrangement 16
Appendix B (normative) pulley logo 18
Foreword
This standard replaces GB/T 13034-2003 "live working with insulating block."
This standard compared with GB/T 13034-2003, this revision of the main contents are.
--- The standard of this chapter, shall be re-arrangement, an increase of Annex A, Annex B.
--- To make the test more realistic conditions, the electrical properties of the test voltage is applied to the way you make changes.
This standard Annex A, Annex B normative appendix.
The standard proposed by China Electricity Council.
This standard by the National Standardization Technical Committee work and live under the jurisdiction responsible for the interpretation.
This standard by the State Grid Wuhan High Voltage Research Institute, Ningbo Tianhe power equipment limited liability company responsible for drafting.
Drafters of this standard. Yi-hui, just to Qiu, Hu Yi, Zhang Lihua.
This standard replaces the standards previously issued as follows.
--- GB/T 13034-1991; GB/T 13034-2003.
Live working with insulating block
1 Scope
This standard specifies the live working with insulating block of requirements, test methods, inspection rules and marking.
This standard applies to insulation block used in live working on high-voltage electrical equipment.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 1303.1 epoxy glass cloth laminate (GB/T 1303.1-1998, neqIEC 60893-3-2.1993)
GB/T 6179 Ⅰ Hexagon slotted nut C class (GB/T 6179-1986, neq ISO /DIS7037. 1982)
GB/T 6181 Hexagon thin slotted nuts Class A and Class B (GB/T 6181-1986, neq ISO /DIS7038. 1982)
GB/T 16927.1 High-voltage test techniques - Part 1. General test requirements (GB/T 16927.1-1997,
eqv IEC 60060-1. 1989)
HG/T 2349 1010 polyamide resin
3 Requirements
3.1 overall technical requirements
a) parts and assemblies after drawing press pass before assembly;
b) After the pulley assembly in the shaft should be rotating flexible without jamming and grazing the rim phenomenon;
c) hooks, rings hanging in the beam should be flexible rotation;
d) The cotter pin can not be bent outward, and removal of excess portion;
e) up the side of the bolt nut portion is not greater than 2mm;
f) side openings in the range of 90 ° without jamming.
3.2 Electrical Performance
Various types of electrical insulation performance should tackle by AC frequency 30kV (rms) 1min pressure test. among them,
Insulated hook-type pulley should be able to exchange power frequency 44kV (rms) 1min pressure test. Test with no heat, no breakdown is qualified.
3.3 Mechanical properties
a) various types of insulation block should satisfy 5kN, 10kN, series rated load 15kN, 20kN requirements (amount here
Fixed load means the load carrying hook);
b) various types of insulation should tackle mechanical performance by 2.0 times the rated load, duration 5min mechanical tension
Test, test with no permanent deformation or cracks qualified;
c) various types of insulation tension pulley destruction not less than 3.0 times the rated load.
3.4 insulating material and process requirements of each pulley member
3.4.1 hooks, rings
3.4.1.1 Materials
Should 40Cr alloy steel or other mechanical properties of structural steel of not less than 40Cr steel.
3.4.1.2 technological requirements
a) must forgings, machined before normalizing;
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 13034-2008_English be delivered?Answer: Upon your order, we will start to translate GB/T 13034-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 13034-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 13034-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 13034-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 13034-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|