Path:
Home >
GB/T >
Page432 > GB/T 13012-2008
|| Home >
Standard_List >
GB/T >
Page432 > GB/T 13012-2008
Price & Delivery
US$454.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 13012-2008: Methods of measurement of d.c. magnetic properties of magnetically soft materials
Status: Valid
GB/T 13012: Evolution and historical versions
| Std ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status |
| GB/T 13012-2008 | English | 454 |
Add to Cart
|
4 days [Need to translate]
|
Methods of measurement of d.c. magnetic properties of magnetically soft materials
| Valid |
| GB/T 13012-1991 | English | 519 |
Add to Cart
|
4 days [Need to translate]
|
Solid steels--Methods of measurement of the d. c. magnetic properties
| Obsolete |
Basic data
| Standard ID | GB/T 13012-2008 (GB/T13012-2008) |
| Description (Translated English) | Methods of measurement of d.c. magnetic properties of magnetically soft materials |
| Sector / Industry | National Standard (Recommended) |
| Classification of Chinese Standard | H21 |
| Classification of International Standard | 77.040.99 |
| Word Count Estimation | 23,266 |
| Date of Issue | 2008-10-10 |
| Date of Implementation | 2009-05-01 |
| Older Standard (superseded by this standard) | GB/T 13012-1991; GB/T 3656-1983; GB/T 3657-1983 |
| Adopted Standard | IEC 60404-2000, IDT |
| Regulation (derived from) | National Standard Approval Announcement 2008 No.17 (Total No.130) |
| Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China |
| Summary | This standard specifies the method for use in a closed magnetic circuit loop -like or soft material permeability measured dc magnetic properties. Ring -like law applies to sheets stacked ring -like or ring -like and overall solid sintered ring -like. This standard specifies the following two methods: a) an annular sample method. Applied magnetic field strength measured at 10kA/m or less, b) permeameter method. For measuring the magnetic field strength in the range between (1 ~ 200) kA/m in. NOTE: On coercivity magnetic measuring method specified by the GB/T 13888-1992 's. |
GB/T 13012-2008: Methods of measurement of d.c. magnetic properties of magnetically soft materials
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Methods of measurement of dc magnetic properties of magnetically soft materials
ICS 77.040.99
H21
National Standards of People's Republic of China
GB/T 13012-2008/IEC 60404-4.2000
Partially replace GB/T 3656-1983, GB/T 3657-1983, instead of the GB/T 13012-1991
Methods of measurement of dc magnetic soft magnetic materials
(IEC 60404-4.2000, IDT)
Posted 2008-10-10
2009-05-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Preface Ⅰ
1 Scope 1
2 Normative references 1
Determination of the magnetic ring-like method can be 1 3
4 with Permeameters method for determining the magnetic properties 6
5 13 test reports
Calibration Appendix A (normative) detection coil 15
Annex B (informative) flux integrator calibration method 16
Requirements Annex C (informative) compensation coil system 19 J
GB/T 13012-2008/IEC 60404-4.2000
Foreword
This standard is identical with IEC 60404-4.2000 "magnetic materials --- Part 4. Methods of measurement of dc magnetic soft magnetic material" (English
Version), the main content and structure of IEC 60404-4.2000 agreement.
For ease of use, this standard has been modified following editorial.
--- The term "this part" (referring to IEC 60404 Part 4) to the "standard";
"." --- With a decimal point instead of a comma as the decimal point, "";
--- Delete foreword international standards;
--- References by corresponding national standards and industry standards were changed;
--- Rearrange the picture number and location.
This standard replaces GB/T 13012-1991 "Methods of measurement of dc magnetic properties of steel", but instead of GB/T 3657-1983 "soft close
Gold dc magnetic measurement method "and GB/T 3656-1983" pure ferromagnetic electrical performance measurements "in" at 25cm double yoke permeameter
Or ring specimens with impact method to measure DC magnetic induction "and" specimen measuring permeability and hysteresis characteristics endless "related content.
The revision of this standard GB/T 13012-1991 been modified following major contents.
--- Change the standard name;
--- Rearrange the structure;
--- Supplementary ring-like law and relevant content Permeameters law;
--- Cancel the original standard of open magnetic methods related content;
--- Cancel the original standard in Appendix A;
--- Increase in Appendices B and C.
Appendix A of this standard is a normative appendix, Appendix B and Appendix C are informative appendices.
The standard proposed by China Iron and Steel Association.
This standard is under the jurisdiction of the National Steel Standardization Technical Committee.
This standard was drafted. Baoshan Iron & Steel Co., Ltd., Metallurgical Industry Information Standards Institute.
The main drafters of this standard. Zhou Xing, Zhi-Yuan Hu, Li Heping, Feng Chao, Ren Cuiying.
This standard replaces the standards previously issued as follows.
--- GB/T 3656-1983;
--- GB/T 3657-1983;
--- GB/T 13012-1991.
GB/T 13012-2008/IEC 60404-4.2000
Methods of measurement of dc magnetic soft magnetic materials
1 Scope
This standard specifies the method for use in a closed magnetic circuit or loop-like magnetic permeability soft magnetic material measuring DC magnetic properties. Ring-like method is suitable for
Sheet stacking ring-like, or whole solid ring-like ring and sintered samples.
This standard specifies the following two methods.
a) an annular sample method, mainly applied to the magnetic field strength measured at 10kA/m or less;
b) permeameter method for measuring the magnetic field strength in the range between (1 ~ 200) kA/m of.
GB/T 13012-2008/IEC 60404-4.2000

Tips & Frequently Asked Questions:
Question 1: How long will the true-PDF of GB/T 13012-2008_English be delivered?
Answer: Upon your order, we will start to translate GB/T 13012-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.
Question 2: Can I share the purchased PDF of GB/T 13012-2008_English with my colleagues?
Answer: Yes. The purchased PDF of GB/T 13012-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.
Question 3: Does the price include tax/VAT?
Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs):
List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?
Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
Question 5: Should I purchase the latest version GB/T 13012-2008?
Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 13012-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.