US$509.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 11441.2-2011: Laminations for transformers and inductors for use in telecommunication and electronic equipment -- Part 2: Specification for the minimum permeabilities of laminations made of soft magnetic metallic materials Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 11441.2-2011 | English | 509 |
Add to Cart
|
4 days [Need to translate]
|
Laminations for transformers and inductors for use in telecommunication and electronic equipment -- Part 2: Specification for the minimum permeabilities of laminations made of soft magnetic metallic materials
| Valid |
GB/T 11441.2-2011
|
PDF similar to GB/T 11441.2-2011
Basic data | Standard ID | GB/T 11441.2-2011 (GB/T11441.2-2011) | | Description (Translated English) | Laminations for transformers and inductors for use in telecommunication and electronic equipment -- Part 2: Specification for the minimum permeabilities of laminations made of soft magnetic metallic materials | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | L17 | | Classification of International Standard | 29.100.10 | | Word Count Estimation | 22,256 | | Date of Issue | 2011-12-30 | | Date of Implementation | 2012-07-01 | | Quoted Standard | GB/T 321-2005; GB/T 11441-1989; GB/T 21219-2007; IEC 60404-8-6-1986; IEC 60404-8-6-1986/COR 1-1992 | | Adopted Standard | IEC 60740-2-1993, MOD | | Regulation (derived from) | National Standard Approval Announcement 2011 No.23 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the definition of GB/T 21219-2007 lowest permeability C2, El, E3 and ferro-silicon and nickel alloy laminations prepared the E4 requirements. These requirements are more suitable for lamination GB/T 11441-1989 listed. Performance requirements in this section apply to sinusoidal flux and frequency of 50Hz or 60Hz test, and after sufficient heat treatment laminations. |
GB/T 11441.2-2011: Laminations for transformers and inductors for use in telecommunication and electronic equipment -- Part 2: Specification for the minimum permeabilities of laminations made of soft magnetic metallic materials
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Laminations for transformers and inductors for use in telecommunication and electronic equipment Part 2. Specification for the minimum permeabilities of laminations made of soft magnetic metallic materials
ICS 29.100.10
L17
National Standards of People's Republic of China
Telecommunication and electronic equipment transformers and inductors laminations
Part 2. Soft metal laminations lowest permeability Specification
Part 2. Specificationfortheminimumpermeabilitiesoflaminations
(IEC 60740-2.1993, MOD)
Issued on. 2011-12-30
2012-07-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
GB/T 11441 "in telecommunication and electronic equipment - transformers and inductors core piece" is divided into the following sections.
--- Part 1. mechanical and electrical properties;
--- Part 2. Soft metal laminations lowest permeability specifications.
This section GB/T 11441 Part 2.
This section based on GB/T 1.1-2009 given rule drafting.
This section uses redrafted law revision using IEC 60740-2.1993 "communication and electronic equipment transformers and inductors laminations
Part 2. Soft metal laminations lowest permeability specification. "
This part of IEC 60740-2.1993 technical differences are.
--- References GB/T 11441-1989 "telecommunication and electronic equipment transformers and inductors laminations" is to modify the use of
IEC 60740. 1982 "transformer and inductor core sheet" (see Part 2);
--- References GB/T 21219-2007 "magnetic classification" Although identical with IEC 60404-1.2000 "magnetic materials
Materials - Part 1. Classification, "but with the IEC 60740-2. 1979 technical differences exist (see.1993 is referenced in IEC 60404-1
Chapter 2 of this section).
This section also includes the following editorial changes.
--- With "this Part" instead of "this International Standard";
--- With "normative references" instead of "reference standard";
--- "IEC designation" to "designation";
--- Instead of using the decimal point as a decimal point ",". ",";
--- In the calculation formula, the value is multiplied by the multiplication sign "×" dot instead of "*";
--- The Figure No. 1 to 7 were changed to Figure 1, a) ~ g);
--- The "IEC 404-8-6" to "IEC 60404-8-6", "IEC 404-1" to "IEC 60404-1";
--- This section IEC 60740-2 7.3 Notes represented by text and formulas. Increments;
--- This section Tables 4 to 9, the lowest permeability units move tabular data;
--- This section omitted the IEC standard foreword and introduction.
This part is proposed by the Ministry of Industry and Information Technology of the People's Republic of China.
This part of the National Magnetic components and ferrite materials Standardization Technical Committee (SAC/TC89) centralized.
This section is responsible for drafting units. China Electronics Technology Group Corporation ninth Institute.
The main drafters of this section. Yu Guojun, Like Wen, Hu Bin.
Telecommunication and electronic equipment transformers and inductors laminations
Part 2. Soft metal laminations lowest permeability Specification
1 Scope
This section GB/T 11441 requirements by GB/T 21219-2007 defined C2, E1, E3 and E4 categories ferrosilicon and ferronickel system
Low permeability prepared laminate requirements. These requirements are more suitable for lamination GB/T 11441-1989 listed. Of this Part
Performance suitable for sinusoidal flux and frequency of 50Hz or 60Hz under test, and after adequate heat treatment of the laminate.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 321-2005 priority number and priority number system (ISO 3. 1973, IDT)
GB/T 11441-1989 communications and electronic equipment for transformers and inductors laminations (eqv IEC 60740. 1982)
GB/T 21219-2007 magnetic classification (IEC 60404-1.2000, IDT)
IEC 60404-8-6. 1986 Magnetic materials - Part 8. Specifications for individual materials - Section 6. soft magnetic metal material
IEC 60404-8-6. 1986 Magnetic materials - Part 8. Specifications for individual materials Section 6. Amendment soft magnetic metal material
1.1992
3 Terms and definitions
GB/T 11441-1989 define the following terms and definitions apply to this document.
3.1
Alloy subcategories aloysubclass
For E1 ~ E4 alloy, alloy expansion of a species (No. 2) Number that represents the shape of the hysteresis loop. Where 1 represents the general arc
Back line, 2 denotes a rectangular loop.
3.2
Magnetic Level magneticgrade
Corresponding to the relative permeability of the material double-digit, when added to the alloy after subcategories, said different magnetic levels.
Grade 4 laminated extension
When it is necessary to laminate a predetermined size, shape and thickness, but also indicate lamination performance, you need to use a particular alloy, it is necessary
GB/T 11441-1989 of 7.1 given grades to be expanded.
Extended Code grades for example as follows.
|