US$419.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB 20041.24-2009: [GB/T 20041.24-2009] Conduit systems for cable management -- Part 24: Particular requirement -- Conduit systems buried underground Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB 20041.24-2009 | English | 419 |
Add to Cart
|
4 days [Need to translate]
|
[GB/T 20041.24-2009] Conduit systems for cable management -- Part 24: Particular requirement -- Conduit systems buried underground
| Valid |
GB 20041.24-2009
|
PDF similar to GB 20041.24-2009
Basic data | Standard ID | GB 20041.24-2009 (GB20041.24-2009) | | Description (Translated English) | [GB/T 20041.24-2009] Conduit systems for cable management -- Part 24: Particular requirement -- Conduit systems buried underground | | Sector / Industry | National Standard | | Classification of Chinese Standard | K65 | | Classification of International Standard | 29.120.10 | | Word Count Estimation | 16,161 | | Date of Issue | 2009-05-06 | | Date of Implementation | 2010-02-01 | | Adopted Standard | IEC 61386-24-2004, IDT | | Regulation (derived from) | Announcement of Newly Approved National Standards No. 6, 2009 (No. 146 overall) | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This Chinese standard specifies requirements and tests for conduit systems buried underground (including conduit and conduit fittings), including those catheter system for the protection and management of electrical devices or communication system of the insulated conductor and/or cable conduits and conduit fittings. This standard applies to metals, non-metallic and composite materials catheter system, including the termination of these conduit systems threaded and non threaded conduit interface. |
GB 20041.24-2009: [GB/T 20041.24-2009] Conduit systems for cable management -- Part 24: Particular requirement -- Conduit systems buried underground ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Conduit systems for cable management.Part 24. Particular requirement.Conduit systems buried underground
ICS 29.120.10
K65
National Standards of People's Republic of China
GB 20041.24-2009/IEC 61386-24.2004
Conduit systems for cable management
Part 24. buried conduit system
special requirements
(IEC 61386-24.2004, IDT)
Posted 2009-05-06
2010-02-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Introduction Ⅲ
1 Scope 1
2 Normative references 1
3 Definitions 1
4 1 General requirements
5 General conditions for test 1
6 Category 1
7 Marking and documents 2
8 Size 2
9 Structure 2
Mechanical properties 2 10
11 Electrical Properties 4
Thermal properties 4 12
13 flame effect 4
14 4 external influences
15 4 Electromagnetic Compatibility
Appendix A (normative) Catheter System classification code 8
Appendix B (normative) Determination of the material thickness of 8
GB 20041.24-2009/IEC 61386-24.2004
Foreword
All technical content in this section is mandatory.
GB 20041 "Conduit systems for cable management" is divided into two parts.
--- Part 1. General requirements (GB/T 20041.1)
--- Part 2. Particular requirements (GB 20041.21 ~ 20041.24)
● Part 21. Particular requirements for rigid conduit systems
● Part 22. Particular requirements for flexible conduit systems
● Part 23. Particular requirements for flexible conduit systems
● Part 24. Particular requirements for conduit systems buried underground
This section of Part 24 GB 20041. This section should be GB/T 20041.1-2005 used in conjunction.
This section identical with IEC 61386-24.2004 (first edition) "Conduit systems for cable management - Part 24. buried conduit
Special requirements "of the system.
This section of the Appendix A, Appendix B is a normative appendix.
This part is proposed by the China Electrical Equipment Industrial Association.
This part of the National Standardization Technical Committee electrical accessories.
This section drafted by. China Electric Apparatus Research Institute, Hangzhou Hongyan Electric Co., Ltd., Guangdong Liansu Technology Industrial Co., Ltd. Foshan
Gao Gu Plastic Co., Ltd., Guangdong CIQ.
The main drafters of this section. Luohuai Ping, single toward Portland, I'm less full, Song Bo, Huang Weiling, Tangnian En, Li Lixin, Zhou Xiaoqing, Zhang Lan Chan.
GB 20041.24-2009/IEC 61386-24.2004
Conduit systems for cable management
Part 24. buried conduit system
special requirements
1 Scope
GB/T 20041.1-2005 content of this chapter by the following alternatives.
This section provides for the buried conduit system (including conduit and conduit fittings) requirements and tests. These include catheter system
For the protection and management of electrical installations or communication systems insulated wire and/or cable conduit and conduit fittings. This standard applies to metallic,
Non-metallic and composite conduit systems, including the termination of these catheter system interfaces catheter threaded and non-threaded.
2 Normative references
The following documents contain provisions which, through reference in this text, constitute provisions of this part. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this section, however, encourage the parties to this part of the research agreement
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this section.
GB/T 20041.1-2005 of this chapter for the following modifications apply.
GB/T 17194 NA
GB 17466-1998 NA
increase.
GB/T 4217-2001 and the nominal outer diameter of said fluid delivery Thermoplastics pipes for the public (eqv ISO 161-1.1996)
GB/T 1804-2000 General tolerances for linear and angular dimensions without individual tolerance tolerance (eqv ISO 2768-1. 1989)
3 Definitions
GB/T 20041.1-2005 this chapter apply.
4 General requirements
GB/T 20041.1-2005 this chapter apply.
5 General conditions for tests
GB/T 20041.1-2005 this chapter apply.
Category 6
GB/T 20041.1-2005 after this chapter apply for the following modifications.
modify.
NOTE. Appendix A is not applicable.
6.1 Mechanical properties classified by
Alternative.
6.1.1 Pressure Resistance
6.1.1.1 250 type (Code 250)
NOTE. Press catheter system 6.1.1.1 Classification expected to bring additional protective measures to install these additional protective measures specified in the relevant national specification.
GB 20041.24-2009/IEC 61386-24.2004
6.1.1.2 450 type (Code 450)
NOTE. Press catheter system 6.1.1.2 Classification without additional protective measures are expected to be directly buried underground.
6.1.1.3 750 type (Code 750)
NOTE. Press catheter system 6.1.1.3 Classification without additional protective measures are expected to be directly buried underground.
6.1.2 Impact
6.1.2.1 Light (Code L)
6.1.2.2 Normal (Code N)
6.1.3 Anti-bending
6.1.3.1 Rigid
6.1.3.2 Flexible
6.2 Classification according to temperature
Not applicable.
7 Marking and documentation
GB/T 20041.1-2005 of this chapter for the following modifications apply.
7.1 Addition.
In addition, the catheter should be marked.
a) by 6.1.2 Classification code "L" or "N";
b) by 6.1.1 Classification code "250", "450" or "750", the code shall be marked immediately after the press a) marked code.
7.1.1 Not applicable
increase.
7.1.101 conduit should be identified in accordance with the requirements of 7.1. Logo should at regular intervals along the full length of the catheter, as the most suitable interval
1m, not more than 3m.
7.3 and 7.4 do not apply.
7.6 Addition.
Note 3 after the increase.
Note 4. considering alternative tests.
increase.
7.101 manufacturers should provide information in its proper installation and use of all safety information required.
In addition, the classification of the catheter system according to 6.1.1.1, the manufacturer shall provide instructions to install protective measures (if appropriate country
Technical regulations).
Size 8
Alternative.
Catheter size should take precedence table 101 in accordance with the requirements.
The minimum inner diameter of qualified or not, by measuring two perpendicular diameters on the same cross section and calculate the average to check.
An outer diameter of qualified or not, using a ring gauge or other appropriate means to check.
9 Structure
Except as follows, GB/T 20041.1-2005 this chapter apply.
9.3 and 9.4 do not apply.
10 Mechanical properties
GB/T 20041.1-2005 of this chapter for the following modifications apply.
GB 20041.24-2009/IEC 61386-24.2004
10.1.4 Replacement.
Compliance is checked by inspection test 10.2 to 10.4.
10.2 Pressure test
Alternative.
10.2.1 catheter is subjected to a pressure test.
Note. Parts of the pressure test is under consideration.
Test catheter containing non-metallic materials to begin trials in their manufacture after 10d.
10.2.2 sample length (200 ± 5) mm.
10.2.3 Test before, according to the provisions of Chapter 8 of the measurement samples of outer and inner diameters.
10.2.4 The sample is pressed between two minimum size of 100mm × 220mm × 15mm flat steel specimen long side facing the plate
The long side 220mm. Press (15 ± 0.5) mm/min rate of pressure samples in the vertical bending load recorded at the equivalent of the original inner diameter of the sample
5% of the average.
10.2.5 When the 5% deformation, applied pressure should be at least.
--- For the catheter according to 6.1.1.1 for the 250N.
--- For the catheter according to 6.1.1.2 for the 450N.
--- For the catheter according to 6.1.1.3 for the 750N.
NOTE. calculated deformation amount in the inner diameter, the outer diameter is sufficient but the measurement. In cases of doubt, we need to measure the inside diameter.
10.2.6 After the test, it should not make light or water into the cracks between the inside and outside.
10.3 Impact test
Alternative.
10.3.1 Test apparatus 101 shown in FIG. 12 for each length (200 ± 5) mm conduit conduit fittings or sample impact test.
Catheter tested separately.
Accessories mounted on the catheter test.
Note 1. If necessary, you can adjust the test conduit fittings, without conditions affect the test results.
Note 2. The hammer is a hammer mass plus the guide bracket.
10.3.2 test equipment to be placed on a stable surface.
Sample into a temperature (-5 ± 1) ℃ the freezer 2h.
Samples were taken from the freezer box, 101 V-shaped seat in Fig shown.
Weight drop impact of each sample 1, sample was removed from the freezer to the completion of the impact between the time should not exceed 10s, such as the energy value
Specified in Table 102.
Conducted on the impact of the weakest parts of the catheter, but within the range 5mm inlet conduit without impact. The point of impact of the catheter specimen
The midpoint of its length.
When 10.3.3 After the test, the sample reached (20 ± 5) ℃, the sample in the vertical position, under its own weight and can no initial velocity case, 10.4.3
Specified in the appropriate ball through the catheter. You can not have signs of cracking, or between the inside and outside so that there can be no light or water
It cracks.
12 samples should be at least nine have passed the test.
10.4 Bending test
Alternative.
10.4.1 use flexible conduit for this test.
10.4.2 by six lengths suitable sample for this test, three samples were tested at room temperature, and the other three at (-5 ± 1) ℃ into
Line test.
For the test under -5 ℃, 2h to put the sample in a freezer.
Test device by the device 102 shown in FIG constitution, conduit bending radius of the minimum bending radius specified by the manufacturer.
GB 20041.24-2009/IEC 61386-24.2004
One end of the sample with a suitable device fixed on the test device, and then the sample was bent nearly 90 ° angle. For in the freezer
Box of samples to be taken from inside the freezer 10s bent.
10.4.3 During the test, the sample should not be crushed.
Whether eligibility, use a diameter equal to the manufacturer's declared minimum inner diameter of the sample (95 + 10) percent of the ball by bending around the test apparatus
Samples to check.
10.5,10.6,10.7 and 10.8 do not apply.
11 Electrical Performance
Except as follows, GB/T 20041.1-2005 this chapter apply.
11.1 to 11.3 is under consideration.
12 Thermal Performance
GB/T 20041.1-2005 This chapter does not apply.
13 flame effect
Except as follows, GB/T 20041.1-2005 this chapter apply.
13.1.2 under consideration.
14 external influences
GB/T 20041.1-2005 this chapter apply.
15 Electromagnetic Compatibility
GB/T 20041.1-2005 this chapter apply.
Table 101 vessel diameter
Nominal dimensions
mm
Nominal outside diameter
mm
tolerance
mm
Minimum inner diameter
mm
2525 +0.5 018
3232 +0.6 024
4040 +0.8 030
5050 +1.0 037
6363 +1.2 047
7575 +1.4 056
9090 +1.7 067
110 110 082 +2.0
125 125 +2.3 094
0 106 140 140 +2.6
0 120 160 160 +2.9
GB 20041.24-2009/IEC 61386-24.2004
Table 101 (continued)
Nominal dimensions
mm
Nominal outside diameter
mm
tolerance
mm
Minimum inner diameter
mm
0135 180 180 +3.3
0150 200 200 +3.6
225 225 +4.1 0170
0188 250 250 +4.5
NOTE. nominal outside diameter according to GB/T 4217.
An outer diameter (the OD) tolerance as follows.
Minimum OD. nominal outside diameter
Maximum OD. nominal outside diameter + (0.018 × nominal diameter value) rounded to 0.1mm.
Minimum diameter. nominal outside diameter divided by 1.33.
Table 102 impact test energy value
Nominal size catheter
mm
Light (L) Normal (N)
Weight quality
kg (+1 0)%
Drop height
mm (0-1)%
energy
Weight quality
kg (+1 0)%
Drop height
mm (0-1)%
energy
≤60 3 100 3 5 300 15
61 ~ 9032006540020
91 to 140,340,012,557,028
> 140,350,015,580,040
GB 20041.24-2009/IEC 61386-24.2004
Tolerance according to GB/T 1804 level of m
1 --- frame;
2 --- support rod;
3 --- graduated scale;
4 --- guide bracket;
5 --- hammer head;
6 --- 120 ° V-shaped seat;
7 --- steel seat.
Note. The design of this figure can not be limited, subject to the icon size requirements.
101 Impact test apparatus
GB 20041.24-2009/IEC 61386-24.2004
1 --- sample;
2 --- bending cylinder in the center;
3 --- base;
4 --- catheter guide block.
FIG bending tester 102
GB 20041.24-2009/IEC 61386-24.2004
Appendix A
(Normative)
Catheter system of classification codes
GB/T 20041.1-2005 This appendix is not applicable.
Appendix B
(Normative)
Determination of material thickness
GB/T 20041.1-2005 of this Appendix apply.
GB 20041.24-2009/IEC 61386-24.2004
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB 20041.24-2009_English be delivered?Answer: Upon your order, we will start to translate GB 20041.24-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB 20041.24-2009_English with my colleagues?Answer: Yes. The purchased PDF of GB 20041.24-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|