HOME   Cart(10)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (25 Oct 2025)

GA 1149-2014 English PDF

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GA 1149-2014EnglishRFQ ASK 8 days [Need to translate] Water mist extinguishing equipment Obsolete GA 1149-2014

PDF similar to GA 1149-2014


Standard similar to GA 1149-2014

GB 4351   GA 602   GB 4066.2   GA 999   

Basic data

Standard ID GA 1149-2014 (GA1149-2014)
Description (Translated English) Water mist extinguishing equipment
Sector / Industry Public Security (Police) Industry Standard
Classification of Chinese Standard C84
Classification of International Standard 13.220.10
Word Count Estimation 57,581
Quoted Standard GB 150.1; GB 150.2; GB 150.3; GB 150.4; GB/T 1226; GB/T 1227; GB 5099; GB 5135.1-2003; GB 5135.9-2006; GB/T 8979; GB/T 9969; GB/T 16172; GB 25972-2010; GA 61-2010; JB/T 9243; JB/T 9273; SY/T 0063-1999; TSG R0004-2009
Adopted Standard ISO 6182-9-2005, NEQ; FM 5560-2012, NEQ; UL 2167-2004, NEQ
Regulation (derived from) Industry Standard Record Announcement No. 4 of 2015 (No. 184 of the General Administration of Quality Supervision, Inspection and Quarantine of the People Republic of China) Circular on the Implementation of the "
Issuing agency(ies) Ministry of Public Security
Summary This standard specifies the terms and definitions, classification and type, basic parameters, requirements, test methods, inspection rules, marking and operating instructions of water mist fire extinguishing devices. This standard applies to water mist fi

GA 1149-2014: Water mist extinguishing equipment

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Water mist extinguishing equipment ICS 13.220.10 C84 People's Republic of China Public Security Industry Standards Water mist fire extinguishing device Issued on. 2014-05-21 2014-05-21 implementation People's Republic of China Ministry of Public Security

Table of Contents

Preface Ⅰ 1 Scope 1 2 Normative references 1 3 Terms and definitions 4 Classification and type 2 5 basic parameters 4 Requirements 5 6 7 Test Method 19 34 8 Inspection Rules 9 signs and instructions 40 Appendix A (normative) Test procedures and means the number of samples 42 Number of Appendix B (normative) set of storage cylinders and sample test procedures 43 Number of Appendix C (normative) reservoir bottle 44 and sample test procedures set Number of Annex D (normative) safety relief device test program and sample 45 Appendix E (normative) pressure relief device test program and sample number 46 Appendix F (Normative Appendix) Test Procedures partition control valve 47 and the number of samples Annex G (normative) Number of pump unit 48 and sample test procedures Annex H (normative) control panel (cabinet) test procedures and the number of samples 49 Annex I (normative) container valve (relief valve), gas check valve, drive means connected pipe test procedures and the number of samples 50 Appendix J (normative) water mist nozzle test procedures and sample number 51 Annex K (normative) Tolerance 54

Foreword

The standard Chapter 5, Chapter 6 (except 6.10.1.1), chapter 8 and 9.1 are mandatory, the rest are recommended. This standard was drafted in accordance with GB/T 1.1-2009 given rules. The reference standard preparation ISO 6182-9.2005 "Part 9 automatic sprinkler system. water mist nozzles" FM5560.2012 "Water mist systems standard" and UL2167.2004 "with a fine water mist fire sprinkler system." This standard was proposed by the Ministry of Public Security Fire Department. This standard by the National Standardization Technical Committee fixed fire extinguishing system Technical Committee (SAC/TC113/SC2) centralized. This standard is drafted by. Ministry of Public Security in Tianjin Fire Research Institute. Participated in the drafting of this standard. Safety Tianjin Shengda Technology Co., Ltd., Shanghai Golden Shield Fire Safety Equipment Co., Ltd., Shanghai with Thai Technology Co., Ltd. fire. The main drafters of this standard. Li, Zhang Qiang, sip Fengying, Liu Lianxi, Yangzhen Ming, HU Qun Ming, Shen He Kun, Liu Xin, Li Baoli, Zhang Junnuo, Wang Jianqiang, in Dongxing, Gan Xiaohong, Zhang Zhaoxian, Cong North China. Water mist fire extinguishing device

1 Scope

This standard specifies the terms and definitions of water mist fire extinguishing device, classification and model, the basic parameters, requirements, test methods, inspection rules, marking Blogs, and instructions for use. This standard applies to water mist fire extinguishing device.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB 150.1 pressure vessels - Part 1. General requirements GB 150.2 pressure vessels - Part 2. Materials GB 150.3 pressure vessels - Part 3. Design GB 150.4 Pressure Vessels Part 4. fabrication, inspection and acceptance GB/T 1226 General Pressure Gauge GB/T 1227 Precision pressure gauge GB 5099 seamless steel gas cylinders GB 5135.1-2003 Automatic sprinkler systems - Part 1. Sprinklers Part 9 GB 5135.9-2006 sprinkler systems. early suppression fast response (ESFR) sprinklers GB/T 8979 nitrogen, high-purity nitrogen, ultra-pure nitrogen GB/T 9969 General Instructions industrial products GB/T 16172 Test method for heat release rate of building materials GB 25972-2010 gas fire extinguishing systems and components GA 61-2010 fixed fire extinguishing system drive, control devices General JB/T 9243 glass gauge JB/T 9273 electrical contacts SY/T 0063-1999 Test method for pipeline leak detection coating Safety Technology Supervision TSGR0004-2009 Stationary Pressure Vessels

3 Terms and Definitions

The following terms and definitions apply to this document. 3.1 Mist watermist At the minimum design working pressure, the spray nozzle is formed on a plane and head down to 1m at the axis of the small droplet diameter Dv0.50 To 200μm, Dv0.99 less than 400μm droplet of water. 3.2 Droplet diameter Dv0.99 dropdiameterDv099 Total volume of liquid in a spray, the percentage of the volume occupied by the droplet diameter or less was 99%.


Refund Policy     Privacy Policy     Terms of Service     Shipping Policy     Contact Information