HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189760 (15 Mar 2025)

GB 4066.2-2004 PDF English


Search result: GB 4066.2-2004 English: PDF
Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
GB 4066.2-2004English90 Add to Cart 0-9 seconds. Auto-delivery. Fire extinguishing media -- Part 2: ABC powder Obsolete


PDF Preview: GB 4066.2-2004


GB 4066.2-2004: PDF in English

GB 4066.2-2004 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 13.220.30 C 84 Replacing GB 4066.2-2004 Fire Extinguishing Media – Part 2. ABC Powder (ISO 7202.1987, Fire Protection – Fire Extinguishing Media – Powder, NEQ) ISSUED ON. AUGUST 5, 2004 IMPLEMENTED ON. FEBRUARY 1, 2005 Issued by. General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of the People's Republic of China. 3. No action is required - Full-copy of this standard will be automatically & immediately delivered to your EMAIL address in 0~60 minutes. Table of Contents Foreword ... 3  1 Application Scope ... 5  2 Normative References ... 5  3 Terms and Definitions ... 5  4 Requirements ... 5  5 Test Methods ... 6  6 Inspection Rules ... 9  7 Marking, Packaging, Operating Instructions, Transportation and Storage 10  Annex A (Normative) Ammonium Dihydrogen Phosphate Content Test Method ... 12  Annex B (Informative) Flowability Test Method ... 15  Foreword Article 4 and Article 6 of this Part are compulsory; the others are voluntary. GB 4066, Fire Extinguishing Media, is divided into two parts. -- Part 1. BC Powder; -- Part 2. ABC Powder. This Part is Part 2 of GB 4066. This Part is nonequivalent to ISO 7202.1987, Fire Protection – Fire Extinguishing Media – Powder, and the major difference between them are as follows. -- some modifications in formatting are made in accordance with the Chinese language codes; -- some expressions applicable to international standards are changed into those applicable to Chinese standards; -- the requirements for moisture content, moisture absorption and color are added; -- the test methods for fire extinguishing performance are modified; -- Annex A “Ammonium Dihydrogen Phosphate Content Test Method” and Annex B “Flowability Test Method” are added. This Part replaces GB 15060-2002, Ammonium Phosphate Fire Extinguishing Powder. In addition to the reference of ISO 7202-1987, this revision is made by referencing United States Federal Specification O-D-1380B 1990.12 Ammonium Phosphate Fire Extinguishing Powder and the third part of Malaysian standard MS 1180 1990 Fire Extinguishing Media – Part 3 – Specification for Powder. Compared with GB 15060-2002, the major changes of this Part are as follows. -- the requirements for color and discharge performance are added; -- the requirements for content, density and grain size distribution are modified; -- the test methods for moisture content and fire extinguishing performance are modified; -- the normative annex “Ammonium Dihydrogen Phosphate Content Test Method” is added (see Annex A); -- the informative annex “Flowability Test Method” is added (see Annex B). From the date of implementation of this Part, GB 13532-1992 General Specifications Fire Extinguishing Media – Part 2. ABC Powder 1 Application Scope This Part of GB 4066 specifies the definition, requirements, test methods, inspection rules, marking, packaging, transportation and storage of ABC fire extinguishing powder. This Part applies to fire extinguishing powders suitable for use against fires of classes A, B and C. 2 Normative References The provisions in following documents become the provisions of this Part of GB 4066 through reference in this Part. For dated references, the subsequent amendments (excluding corrigendum) or revisions do not apply to this Part, however, parties who reach an agreement based on this Part are encouraged to study if the latest versions of these documents are applicable. For undated references, the latest edition of the referenced document applies. GB 4066.1-2004, Fire Extinguishing Media – Part 1. BC Powder (ISO 7202.1987, NEQ) GB/T 6682-1992, Water for Analytical Laboratory Use – Specification and Test Methods (neq ISO 3696.1987) 3 Terms and Definitions The following term and definition applies to this Part of GB 4066. 3.1 ABC fire extinguishing media – powder fire extinguishing powders suitable for use against fires of classes A, B and C 4 Requirements The main performance of ABC fire extinguishing powder shall be as specified in Table 1. Table 1 Item Technical requirement Carry out tests as specified in 5.4 of GB 4066.1-2004. 5.5 Resistance to caking and lumping Carry out tests as specified in 5.5 of GB 4066.1-2004. 5.6 Water repellency Carry out tests as specified in 5.6 of GB 4066.1-2004. 5.7 Grain size distribution Carry out tests as specified in 5.7 of GB 4066.1-2004. 5.8 Resistance to extreme low temperature Carry out tests as specified in 5.8 of GB 4066.1-2004. 5.9 Electrical insulation Carry out tests as specified in 5.9 of GB 4066.1-2004. 5.10 Color Place sample of fire extinguishing powder loosely in a container; observe the color of sample by visual inspection. 5.11 Discharge performance 5.11.1 Method I (arbitration test) Carry out tests as specified in 5.11.1 of GB 4066.1-2004. 5.11.2 Method II 5.11.2.1 Apparatus a) 8 kg stored pressure ABC powder fire extinguisher. as specified in GB 4351; b) vibration table. amplitude 3 mm and frequency (10 ~ 80) Hz; c) electrothermal blowing drying oven. accuracy ± 2°C; d) platform balance. accuracy 0.05 kg; e) stopwatch. division value 0.1 s. 5.11.2.2 Test procedure Carry out tests as specified in 5.11.2.2 of GB 4066.1-2004. b) when there is any significant change such as in raw materials and process after normal production; c) during the periodical inspection at a two years’ interval during normal production; d) when the production is resumed after a production halt of more than 1 year; e) when a national quality supervision body asks for type inspection. 6.2 Batch and lot A batch is a single charge of material in the processing equipment that has been made homogeneous. A lot contains one or more batches of products, manufactured to the same formulation by the same manufacturing process and under the same environmental conditions. 6.3 Sampling 6.3.1 Samples for type inspection shall be taken from the qualified products by exit- factory inspection. Before sampling, mix up products homogeneously; before the test for each item of performance, samples shall be mixed up. 6.3.2 When sampling a lot or a batch, samples of not less than 50 kg shall be taken at random. The samples taken shall be stored in individual, clean, dry, airtight containers. 6.4 Evaluation of inspection results The results of exit-factory inspection and type inspection shall be as specified in the technical requirements of Article 4 of this Part; If one item is not as specified in this Part, then they are decided to be nonconforming products. 7 Marking, Packaging, Operating Instructions, Transportation and Storage 7.1 Marking The manufacturer or supplier shall provide, marked on each separate package, the information including manufacturer name, address, product name, main fire extinguishing constituent and content, trademark, standard number, manufacturing date or batch number, conformity mark, quality and applicable fire class and simple storage requirements. 7.2 Packaging a) balance. sensitivity 0.2 mg; b) crucible filter. no. 4, volume 30 mL; c) graduated beaker. volume 400 mL; d) electrothermal constant-temperature drying oven. accuracy ± 2°C; e) closed electric furnace. A.4 Test procedure A.4.1 Preparation of solution to be tested a) Weigh 1 g of ammonium phosphate fire extinguishing powder sample, accurate to 0.000 2 g, place in a 100-mL beaker, add 2 mL of acetone and keep stirring. b) After acetone evaporates, add a small amount of hot grade 3 water at (60 ~ 70)°C to dissolve and filter, use about 250 mL of grade 3 water to wash undissolved substances, collect the filtrate and washing in a 500-mL volumetric flask, use grade 3 water to dilute to 500 mL, shake up. The solution obtained is solution to be tested A. A.4.2 Use a pipette to absorb 25 mL of solution A to transfer to a 400-mL beaker, add 10 mL of nitric acid solution, use grade 3 water to dilute to 100 mL and preheat to nearly boiling. Add (40 ~ 45) mL of quinolamethanone reagent, put on the cover for the watch glass, heat to slightly boiling for 1 min on a closed electric furnace or place on a water bath to preserve heat until the precipitates separate into layers, take the beaker out, cool to room temperature and rotate the beaker for 3 to 4 times during the cooling process. A.4.3 Filter on a crucible filter which has been pre-dried for 45 min at (180 ± 2)°C, filter all supernatant liquid before using about 100 mL of grade 3 water to wash precipitates, place the precipitates and filter in an electrothermal constant-temperature drying oven to dry for 45 min at (180 ± 2)°C, transfer to a desiccator to cool for 45 min and weigh. A.5 Results Ammonium dihydrogen phosphate content x1 (%) in samples is calculated in accordance with Formula (1). where, m0—the mass of sample taken during test, in g; ......
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.