0-9 seconds. Auto-delivery.
|
dry powder fire extinguishing equipment
| Obsolete |
Standards related to: GA 602-2013
PDF Preview
GA 602-2013: PDF in English GA 602-2013
GA
PUBLIC SECURITY INDUSTRY STANDARD
OF THE PEOPLE’S REPUBLIC OF CHINA
ICS 13.220.10
C 84
Replacing GA 602-2006
Dry powder fire extinguishing equipment
干粉灭火装置
ISSUED ON. DECEMBER 17, 2013
IMPLEMENTED ON. MARCH 1, 2014
Issued by. Ministry of Public Security of the People's Republic of China
Table of Contents
Foreword ... 4
1 Scope ... 7
2 Normative References ... 7
3 Terms and definitions ... 8
4 Classification ... 9
5 Designation ... 10
6 Requirements ... 11
7 Test method ... 29
8 Inspection rules ... 56
9 Instruction manual ... 61
Annex A (Normative) Test procedure and sample quantity for dry powder fire
extinguishing equipment ... 64
Annex B (Normative) Test procedure and sample quantity for container
valve ... 66
Annex C (Normative) Test procedure and sample quantity for actuating
equipment ... 67
Annex D (Normative) Test procedure and sample quantity of controlling and
activating assembly ... 68
Annex E (Normative) Test procedure and sample quantity for pressure
indicator ... 70
Annex F (Normative) Test procedure and sample quantity for electrical
trigger ... 72
Annex G (Normative) Test procedure and sample quantity for heat trigger
... 73
Annex H (Normative) Test procedure and sample quantity for fusible alloy
assembly and temperature-actuated glass bulb assembly ... 74
Annex I (Normative) Test procedure and sample quantity for temperature-
actuated magnetic generator assembly ... 75
Annex J (Normative) Test procedure and sample quantity for nozzle ... 77
Annex K (Normative) Test procedure and sample quantity for hanger
bracket (support) ... 78
Annex L (Normative) Test procedure and sample quantity for signal
feedback equipment ... 79
Foreword
Chapter 5, Chapter 6 [except 6.16.4, 6.20.3.8, 6.25, 6.26.1 a] and 6.27.1 a)], Chapter
8 and 10.1.1 are compulsory; the others are voluntary.
This Standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This Standard replaces GA 602-2006, Dry chemical fire extinguishing equipment.
Compared with GA 602-2006, the main technical changes of this Standard are as
follows.
-- it modifies the normative references (see Chapter 2; Chapter 2 of 2006);
-- it modifies the definition of dry powder fire extinguishing equipment (see 3.1; 3.1
of Edition 2006);
-- it adds the definition of temperature-actuated magnetic generator (see 3.5), the
definition of stored mechanical energy discharge equipment (see 3.6) and
controlling and activating package (see 3.7);
-- it adds the classification method for the particle size of dry powder fire
extinguishing equipment (see 4.4);
-- it adds the classification method based on the using places where dry powder fire
extinguishing equipment is used (see 4.5; 4.5 of Edition 2006);
-- it modifies the classification method based on the actuating methods of dry
powder fire extinguishing equipment (see 4.6; 4.4 of Edition 2006);
-- it modifies the designation method (see Chapter 5; Chapter 5 of Edition 2006);
-- it modifies the range of working temperature (see 6.1.1; 6.1.1 of Edition 2006);
-- it adds other performance of non-storage-pressure fire extinguishing equipment
(see 6.5.3);
-- it modifies the requirements for the quality deviations of filling of dry powder fire
extinguishing agent (see 6.6; 6.7 of Edition 2006);
-- it adds the damp-heat resistance performance (see 6.7.2.2), vibration resistance
performance (see 6.8.2) and salt spray resistance performance (see 6.9.2) of
special-purpose fire extinguishing equipment;
-- it adds the requirements for the reactions and action times of non-storage-
pressure fire extinguishing equipment (see 6.10);
-- it adds the linkage performance (see 6.11);
Dong Haibin, Sheng Yanfeng, Ma Jianqin, Zhao Qingsong, Qin Yuwang, Hong Weiyi,
Mi Qiulin, Gao Chunlai and Lian Rong.
The previous edition replaced by this Standard is as follows.
-- GA 602-2006.
Dry powder fire extinguishing equipment
1 Scope
This Standard specifies the terms and definitions, classification, designation,
requirements, test methods, inspection rules, instruction manual and marking,
packaging, transportation and storage of the dry powder fire extinguishing equipment.
This Standard applies to stationary-mounted dry powder fire extinguishing equipment
of hanging type, wall mounting type and other types; it does not apply to dry powder
fire extinguishing equipment of cabinet type and mobile type.
2 Normative References
The following referenced documents are indispensable for the application of this
document. For dated references, only the edition dated applies to this document. For
undated references, the latest edition of the referenced documents (including all
amendments) applies to this Standard.
GB 150 (all parts), Steel pressure vessels
GB 190, Packing symbol of dangerous goods
GB/T 191, Packaging – Pictorial marking for handling of goods
GB 252, General diesel fuels
GB 4066.1, Fire extinguishing media – Part 1. BC powder
GB 4066.2, Fire extinguishing media – Part 2.ABC powder
GB 5100, Welded steel gas cylinders
GB 5135.1-2003, Automatic sprinkler system – Part 1. Sprinkler
GB/T 7094-2002, Vibration (sinusoidal) test method for electrical installations in
ships
GB/T 8979, Pure nitrogen and high purity nitrogen and ultra-pure nitrogen
GB 9108, Safety fuse
GB/T 9969, General principles for preparation of instructions for use of industrial
products
GB/T 11121, Gasoline engine oils (Translator note. the Chinese standard number
should be GB 11121)
GB 12463, General specifications for transport packages of dangerous goods
GB 18428-2010, Glass bulbs used for automatic fire extinguishing systems
GB/T 25208-2010, Environmental test methods for fixed extinguishing systems
GB 25972-2010, Gas fire extinguishing systems and components
GA 13-2006, Hanging gaseous fire extinguishing equipment
GA 61-2010, General technical specifications of actuating and control devices of
fixed extinguishing systems
GA 306.2-2007, Flame retardant and fire resistive cables – Classification and
requirement for flame retardant and fire resistive characteristics of plastic insulated
cables – Part 2. Fire resistive cables
GA 499.1-2010, Aerosol fire extinguishing system – Part 1. Condensed aerosol fire
extinguishing device
GA 578, Super fine powder fire extinguishing agent
GA 863-2010, General requirements for fusible element for fire protection
JB/T 7366, Design calculation for flat spiral springs
3 Terms and definitions
For the purpose of this document, the following terms and definitions apply.
3.1
dry powder fire extinguishing equipment
the powder fire extinguishing equipment which is mounted in a protected area,
activated by automatic detection or manually by control device and actuated by
actuating medium (gas or fuel gas) or mechanical energy
3.2
ratio of residual extinguishing agent discharge
the ratio of the mass of residual fire extinguishing agent inside after the spraying of the
fire extinguishing equipment to the mass of fire extinguishing agent filled before the
spraying.
3.3
storage pressure
the balanced pressure of the storage container of the storage pressure fire
extinguishing equipment which is filled with fire extinguishing agent as specified and
placed in the environment at 20°C
3.4
maximum working pressure
the balanced pressure of the storage container of the storage pressure fire
extinguishing equipment which is filled with fire extinguishing agent and placed at the
upper limit of the working temperature range
3.5
temperature-actuated magnetic generator
the assembly which can activate the fire extinguishing equipment through the action of
cutting magnetic force line inside of the assembly, without being connected to an
external power supply
3.6
stored mechanical energy discharge equipment
the equipment with which the mechanical structure of stored energy releases energy
to actuate the fire extinguishing equipme...
...... Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.
|