FZ/T 01116-2012: Textiles. Testing and evaluation for magnetic property
Status: Valid
| Std ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status |
| FZ/T 01116-2012 | English | 149 |
Add to Cart
|
3 days [Need to translate]
|
Textiles. Testing and evaluation for magnetic property
| Valid |
Basic data
| Standard ID | FZ/T 01116-2012 (FZ/T01116-2012) |
| Description (Translated English) | Textiles. Testing and evaluation for magnetic property |
| Sector / Industry | Spinning & Textile Industry Standard (Recommended) |
| Classification of Chinese Standard | W04 |
| Classification of International Standard | 59.080.30 |
| Word Count Estimation | 6,689 |
| Quoted Standard | GB/T 6529 |
| Regulation (derived from) | Ministry of Industry and Information Technology Bulletin 2012 No. 70; industry standard filing Notice 2013 No. 2 (No. 158 overall) |
| Issuing agency(ies) | Ministry of Industry and Information Technology of the People's Republic of China |
| Summary | This standard specifies test methods textiles magnetic, and gives the textile magnetic powder load evaluation. This standard applies to all kinds of textile fabrics and articles thereof. |
FZ/T 01116-2012: Textiles. Testing and evaluation for magnetic property
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Textiles.Testing and evaluation for magnetic property
ICS 59.080.30
W04
People's Republic of China textile industry standards
Testing and evaluation of magnetic properties of textiles
Issued on. 2012-12-28
2013-06-01 implementation
Ministry of Industry and Information Technology of the People's Republic of China released
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
The standard proposed by China Textile Industry Association.
This standard by the National Standardization Technical Committee on Basic Standards Subcommittee Textiles (SAC/TC209/SC1) centralized.
This standard was drafted. Textile Standard (Beijing) Inspection and Certification Center Co., Ltd., Beijing high-tech Co. Jlsun.
The main drafters of this standard. Liu Feifei, Zheng Yuying, business Cheng Jie.
Testing and evaluation of magnetic properties of textiles
1 Scope
This standard specifies the method for testing the magnetic properties of textiles and textile products given magnetic powder load evaluation index.
This standard applies to all types of textile fabrics and products.
NOTE. This standard does not involve the evaluation of magnetic health.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 6529 Textiles Standard conditioning and testing atmosphere
3 Terms and Definitions
The following terms and definitions apply to this document.
3.1
Magnetic induction magneticinduction
Characterization of magnetic physical quantity, is numerically equal to the magnetic field perpendicular to the direction of the long 1m, current conductors 1A of the large magnetic forces suffered
Small in Tesla (T) or milli-Tesla (mT) represents.
Principle 4
Under the test conditions specified, will use Hall-effect principle teslameter probe into close contact with and perpendicular to the surface of the sample, the test sample
Like a certain number of points of law to the position of the magnetic flux density, and the average test data as the test result.
5 Instruments
5.1 Tesla
Tesla meter should meet the following criteria.
--- Resolution of not less than 0.001mT;
--- Having a relative measurement mode (ie, when the target magnetic field test instrument is first probe is placed in a test environment for system calibration, instrument making
The initial value of zero in a test environment);
--- Hall element surface plane of the test probe (i.e., end faces) Distance δ is 0.5mm ± 0.05mm (see FIG. 1);
--- With automatic data recording function.

Tips & Frequently Asked Questions:
Question 1: How long will the true-PDF of FZ/T 01116-2012_English be delivered?
Answer: Upon your order, we will start to translate FZ/T 01116-2012_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.
Question 2: Can I share the purchased PDF of FZ/T 01116-2012_English with my colleagues?
Answer: Yes. The purchased PDF of FZ/T 01116-2012_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.
Question 3: Does the price include tax/VAT?
Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs):
List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?
Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.