GB/T 18418-2017English210 Add to Cart 0-9 seconds. Auto-delivery. Domestic sanitary insecticide -- Electrothermal vaporizing liquid Valid
GB/T 18418-2009English519 Add to Cart 3 days Domestic sanitary insecticide -- Electrothermal vaporizing liquid Obsolete
GB 18418-2001English679 Add to Cart 5 days Domestic sanitary insecticide -- Electrothermal mosquito liquid incense Obsolete
Standards related to (historical): GB/T 18418-2017
PDF Preview

GB/T 18418-2017: PDF in English (GBT 18418-2017)

GB/T 18418-2017 NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 65.100.10 G 25 Replacing GB/T 18418-2009 Domestic sanitary insecticide - Electrothermal vaporizing liquid ISSUED ON: DECEMBER 29, 2017 IMPLEMENTED ON: APRIL 01, 2018 Issued by: General Administration of Quality Supervision, Inspection and Quarantine; Standardization Administration of PRC. Table of Contents Foreword ... 3  1 Scope ... 5  2 Normative references ... 5  3 Terms and definitions ... 6  4 Requirements ... 6  5 Test method ... 7  6 Inspection rules ... 9  7 Marking, packaging, transportation, storage, instructions for use ... 12  Appendix A (Normative) Requirements and test methods of electric heater .. 14  Domestic sanitary insecticide - Electrothermal vaporizing liquid 1 Scope This standard specifies the terms and definitions, requirements, test methods, inspection rules and markings, packaging, transportation, storage, use instructions of electrothermal vaporizing liquid (including electric heaters) for domestic sanitary insecticide. This standard is applicable to products in which the smokable mandrel is placed in a bottle filled with a liquid-medicine and heated by a matching electric heater, acts on the mosquito in a gaseous state, has a mosquito-repellent effect. 2 Normative references The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) are applicable to this standard. GB/T 1002 Single-phase plugs and sockets for household and similar purpose - Types, basic parameters and dimensions GB/T 2099.1 Plugs and socket-outlets for household and similar purposes - Part 1: General requirements GB/T 2423.8-1995 Environmental testing for electric and electronic products - Part 2: Test methods - Test Ed: Free fall GB/T 2828.1-2012 Sampling procedures for inspection by attributes - Part 1: Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot inspection GB/T 2829-2002 Sampling procedures and tables for periodic inspection by attributes (Apply to inspection of process stability) GB 4706.1-2005 Household and similar electrical appliances - Safety - Part 1: General requirements GB 4706.81-2014 Household and similar electrical appliances - Safety a suction rod, a stopper, a cap. 4.2.2 Dimensions of the external thread of the liquid-medicine bottle with a thread: the outer diameter D of the thread is ; the pitch t is 2.5 mm; the width A of the thread is 1.25 mm; the height h of the thread is more than 0.95 mm. 4.3 Sense 4.3.1 The same product can be odorless or multiple flavors; its flavor shall be consistent with the stated flavor. 4.3.2 The liquid-medicine shall be clear, without flocculent, delamination, crystallization, or precipitation. 4.3.3 There shall be no obvious smoke or odor during normal use. 4.4 Tightness After the liquid-medicine bottle has passed the 5.4 test, there shall be no spillage of the liquid-medicine on the outside of the bottle. 4.5 Free fall After the liquid-medicine bottle has passed the 5.5 test, there shall be no spillage of liquid-medicine on the outside of the bottle, no damage to the bottle; meanwhile the suction rod shall not break. 4.6 Evaporation rate When it is continuously used to the half time of the stated time, the remaining liquid-medicine as tested shall be not lower than 30% of the stated net content; the content of the active ingredient of the remaining liquid-medicine shall not be less than 80% of the stated content. 4.7 Electric heater See Appendix A for technical requirements for electric heaters. 5 Test method 5.1 General The requirements for the use of active ingredients, toxicology, active ingredient content, allowable fluctuation range, efficacy, heat storage stability, minimum retention period of electrothermal vaporizing liquid, the net content of double-sampling samples is 4. It allows for 1 sample to be unqualified, otherwise it is determined as unqualified. 7 Marking, packaging, transportation, storage, instructions for use 7.1 Marking 7.1.1 The following Chinese content shall be on the product or packaging: a) Product name, trademark, manufacturer's name, location; b) Active ingredients and content; c) Implemented standard number of product; d) Production date, product lot number and expiration date; e) Product quality inspection conformity mark; f) Model or specification; g) Pesticide registration certificate number or pesticide temporary registration certificate number; h) Pesticide production approval document number or production license number; i) Toxicity identification; j) Precautions (e.g. keep away from children, do not store in high temperature, open flames, etc.) k) Net content of electrothermal vaporizing liquid; l) Minimum duration of electrothermal vaporizing liquid; m) The length of special wire of special specification must be specified. 7.1.2 The product’s packaging box shall have the following Chinese content: a) Graphical signs for packaging, storage and transportation; b) Product name and specifications; c) Quantity; d) Gross weight; Appendix A (Normative) Requirements and test methods of electric heater A.1 Requirements A.1.1 Appearance A.1.1.1 Plastic parts must not have obvious plastic defects or warping deformation, cracks, scratches, burrs. A.1.1.2 Each component of the electric heater is assembled tightly; the fasteners must not be loose. A.1.1.3 Metal parts shall not have rust spots. A.1.2 Operating temperature (radiation temperature) and deviation of electric heater The operating temperature (radiation temperature) of the electric heater is determined by the manufacturer. It shall be clearly stated on the appliance or packaging. The temperature deviation is ± 7 °C. A.1.3 Voltage fluctuation characteristics The power supply’s voltage varies within ± 10% of the rated voltage and shall not affect normal use. A.1.4 Protection against touching live parts The structure and enclosure of the appliance shall be adequately protected against accidental exposure to live parts. A.1.5 Input power and current For appliances with an input power not greater than 25 W at the rated voltage and under normal operating temperature, the deviation of their input power or working current from their rated input power or rated current shall not be more than + 20%. A.1.6 Heating A.1.6.1 The surface temperature rise of the hand holding part of the enclosure of the electric heater shall not exceed 50 K. requirements of A.1.4, A.1.7, A.1.8, A.1.15. A.1.11.3 Structure The product shall be a category II electrical structure and meet the relevant requirements of Chapter 22 of GB 4706.81-2014. A.1.12 Internal wiring A.1.12.1 It shall comply with the provisions of Chapter 23 of GB 4706.1-2005. A.1.12.2 After the test of A.2.14.2, the appliance shall meet the requirements of A.1.5 and A.1.17 and the electrical connections shall not be loose. A.1.13 Screws and connections It shall comply with the provisions of Chapter 28 of GB 4706.1-2005. A.1.14 Power connection and external flexible cords and plugs A.1.14.1 Power cord A.1.14.1.1 For electric heaters with power cords, the nominal cross-sectional area of the conductors within 2000 mm shall not be less than 0.5 mm2; the length of products with special specifications within 1000 mm shall be specified, which shall not be less than the indicated value. A.1.14.1.2 The power cord shall meet the requirements of the compulsory certification of the relevant state departments. A.1.14.2 Tension of power cord The power cord shall have a fixing device to prevent it from being pulled out of the electric heater. It can withstand a tension test of 30 N for 25 times. During the test, the power cord shall not be damaged. After the test, the vertical displacement of the power cord shall not exceed 2 mm. There shall be no significant tension at the wiring terminal. A.1.14.3 Bending resistance of power cord A.1.14.3.1 For electric heaters without reels, the power cord shall be subject to bending resistance test. A.1.14.3.2 The entrance of the power cord into the appliance shall be subject to the bending resistance test for 10000 times. After the test, the insulation shall not be damaged; the sheath shall not fall off; the breaking strand of copper core shall not exceed 10%. A.1.14.4 Plug The plugs shall be non-reconnectable plugs that comply with the requirements of GB/T 1002 and GB/T 2099.1. A.1.15 Creepage distances, clearances, solid insulation A.1.15.1 Reinforced insulation clearances and creepage distances between live parts of electric heaters of different potentials, and between live parts and their accessible surfaces shall meet the requirements of Table A.1. Table A.1 Unit: mm Place Electrical clearance Creepage distance Between live parts with different potentials ≥ 2.0 2.0 Between live parts and easily accessible surfaces ≥ 3.5 5.0 A.1.15.2 Additional insulation and reinforced insulation shall have sufficient thickness or sufficient number of layers to withstand the electrical stresses that may occur during use of the appliance. A.1.16 Heat resistance The enclosure must have sufficient heat resistance. After passing the ball pressure test, the diameter of the indentation shall not be more than 2 mm. A.1.17 Indication device The electric heater shall have a power-on indicating device. A.1.18 Signs and instructions A.1.18.1 The appliance shall be marked with the following contents: a) Rated voltage or rated voltage range, in volts (V); b) Symbol of the nature of the power supply, except those marked with a rated frequency; c) Rated input power, in watts (W), or rated current, in amps (A); d) Name, trademark or identification mark of the manufacturer or responsible underwriter; e) Appliance name, model or serial number; f) Symbols of category II structure (category II appliances only); g) IP code of waterproof grade, IPXO is not marked. A.1.18.2 The product packaging contains the following: A.2.2.8 The arbitration of the operating temperature (radiation temperature) and deviation of the electric heater shall be inspected according to Method 2. A.2.3 Voltage fluctuation characteristics At an ambient temperature of (23 ± 2) ° C and a relative humidity of (65 ± 15)%, when the regulation voltage is respectively at the two voltage values of the rated voltage ± 10%, it shall still be used normally. A.2.4 Protection against touching live parts It is performed according to the relevant requirements of Chapter 8 of GB 4706.1-2005. A.2.5 Input power and current It is performed according to the relevant requirements of 10.1, 10.2 in GB 4706.81-2014. A.2.6 Heating Apply 1.06 times the rated voltage. Continuously energize for 2 h. Measure the surface temperature rise value of the part held by the hand of the electric heater’s enclosure. The test is performed according to the method required in Chapter 11 of GB 4706.1-2005. A.2.7 Leakage current A.2.7.1 Leakage current at operating temperature It is performed according to the relevant methods in Chapter 13 of GB 4706.1- 2005. The test voltage is 1.06 times the rated value. A.2.7.2 Tide leakage current It is performed according to the conditions and methods of 15.3 and 16.2 in GB 4706.1-2005. The test voltage is 1.06 times the rated value. A.2.8 Electrical strength A.2.8.1 Electrical strength at cold state It is performed according to the conditions and methods of 16.3 in GB 4706.1- 2005. The test set current is 100 mA. A.2.8.2 Electrical strength at operating temperature It is performed according to the relevant methods in 13.3 of GB 4706.1-2005. The test set current is 100 mA. A.2.13 Screws and connections It is performed according to the method stipulated in Chapter 28 of GB 4706.1- 2005. A.2.14 Power connection, external flexible cords and plugs A.2.14.1 Power cord’s size A.2.14.1.1 The length is measured by a steel tape measure, from the point where the power cord or sheath enters the appliance to the inlet of the plug. A.2.14.1.2 Perform visual inspection on whether the relevant materials for compulsory product certification are provided. A.2.14.2 Power cord Perform testing in accordance with the relevant methods of 25.7 of GB 4706.1- 2005. A.2.14.3 Tension of power cord It is performed according to the provisions of 25.15 in GB 4706.1-2005. A.2.14.4 Bending resistance of power cord It is performed according to the provisions of 25.14 in GB 4706.1-2005. A.2.14.5 Plug It is performed according to the relevant requirements in GB/T 1002 and GB/T 2099.1. A.2.15 Creepage distances, clearances, and solid insulation It is measured according to the method specified in Chapter 29 of GB 4706.1- 2005. A.2.16 Heat resistance It is performed according to the provisions of 30.1 in GB 4706.1-2005. A.2.17 Indication device Check if the electric heater has an indicating device when the power is turned on. A.2.18 Signs and instructions It is performed according to the relevant provisions of Chapter 7 of GB 4706.1- ......
 
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.