JJG 1078-2012: Verification Regulationof X-ray Radiation Sources for Medical Computed Radiography System and Digital Radiography System
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJG 1078-2012English369 Add to Cart 3 days [Need to translate] Verification Regulationof X-ray Radiation Sources for Medical Computed Radiography System and Digital Radiography System Valid JJG 1078-2012

PDF similar to JJG 1078-2012


Standard similar to JJG 1078-2012

GB/T 3222.1   JJG 188   JJF 1396   JJF 2017   JJF 1928   JJF 1927   

Basic data

Standard ID JJG 1078-2012 (JJG1078-2012)
Description (Translated English) Verification Regulationof X-ray Radiation Sources for Medical Computed Radiography System and Digital Radiography System
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A58
Classification of International Standard 17.240
Word Count Estimation 16,169
Quoted Standard JJG 774-2004; JJF 1035-2006; GB 9706.3-2000; GB/T 10149; AAPM REPORT NO.93; WS 76-2011; GBZ 187-2007; YY/T 0741-2009
Regulation (derived from) AQSIQ Announcement No. 96 of 2012
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine
Summary This standard applies to medical X-ray imaging system computer (Computed Radiography System, referred to the CR system), digital X-ray system twisted shape (Digital Radiography System, abbreviated DR systems) X-ray radiation of the initial verification, t

JJG 1078-2012: Verification Regulationof X-ray Radiation Sources for Medical Computed Radiography System and Digital Radiography System


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Verification Regulationof X-ray Radiation Sources for Medical Computed Radiography System and Digital Radiography System State verification procedures People's Republic of China Medical digital photography (CR, DR) system X-ray radiation source Issued on. 2012-06-18 2012-09-18 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Medical digital photography (CR, DR) system X-ray radiation source verification procedures stem Focal point. the National Technical Committee of ionizing radiation metrology Main drafting unit. Jiangsu Province Institute of Metrology Jiangsu Provincial People's Hospital Shandong Province Institute of Metrology Participated in the drafting unit. Beijing Institute of Metrology detection Fujian Institute of Metrology This procedure commissioned the National Technical Committee is responsible for ionizing radiation measurement interpretation The main drafters of this procedure. Hu Shang Ze (Jiangsu Province Institute of Metrology) Hu Yibin (Jiangsu Provincial People's Hospital) Ren Hongwei (Shandong Province Institute of Metrology) Yao Shao Wei (Jiangsu Province Institute of Metrology) Rong Xia Xun (Jiangsu Province Institute of Metrology) Drafters participate. Ask Lu (Beijing Institute of Metrology detection) Dong Xu (Fujian Institute of Metrology)

table of Contents

Introduction (Ⅱ) 1 Scope (1) 2. References (1) 3 terminology and units of measurement (1) 3.1 The term (1) 3.2 units of measurement (2) 4 Overview (2) 5 metering performance requirements (2) 5.1 radiation output of air kerma (2) Repeatability 5.2 radiation output (2) 5.3 Quality radiation output (2) Spatial resolution 5.4 (2) 5.5 low contrast resolution (2) 5.6 image uniformity (2) 5.7 light field and the radiation field consistency (2) 5.8 effective focal spot size (2) 5.9 X-ray tube voltage (2) 6 General Requirements (3) 7 control of measuring instruments (3) 7.1 test conditions (3) 7.2 test items and test methods (3) 7.3 Verification Results Processing (6) 7.4 test cycle (7) Appendix A CR, DR performance measurement phantom technical requirements (8) Appendix B calibration certificate and test results notice (within the page) format (9) Appendix C test original record format (10)

Introduction

This procedure is a combination of the current situation of medical digital photography equipment performance and image quality evaluation, and refer to the relevant International recommendations and national standards on the basis of established. Medical digital photography (CR, DR) system X-ray radiation source verification procedures

1 Scope

The order applies to medical X-ray imaging computer system (ComputedRadiographySystem, Acronym CR systems), digital X-ray imaging system (DigitalRadiographySystem, referred to as DR systems) X-ray Emitter initial verification, subsequent verification and the use of checks. This procedure does not apply to breast, and dental digital photography system test X-ray radiation source. 2. References This procedure references the following documents. JJG 744-2004 diagnostic X-ray radiation JJF1035-2006 ionizing radiation measurement terms and definitions GB 9706.3-2000 Medical electrical equipment - Part 2. High-voltage generator means of diagnostic X-ray generator Requirements for safety GB/T 10149 X-ray equipment for medical terminology and symbols AAPMREPORTNO.93- ray image forming system acceptance testing and quality control (Acceptance TestingandQualityControlofPhotostimulableStoragePhosphorImagingSystems) WS76-2011 conventional X-ray diagnostic equipment for medical image quality control testing specification GB Z187-2007 computer X-ray photography (CR) quality control testing specification YY/T 0741-2009 digital medical X-ray imaging system dedicated technical conditions For dated references, only the dated edition applies to this procedure; undated reference documents Member, the latest edition (including any amendments) applies to this procedure.

3 terminology and units of measurement

JJF1035-2006 and GB/T 10149 and defined by the following terms and definitions apply to this procedure. 3.1 Terms 3.1.1 Computer X-ray imaging system computedradiographysystem Using imaging plates instead of intensifying screen film can be reused as a carrier through the X-ray exposure, and then the laser scanning Access to equipment image information. Acronym CR system. 3.1.2 The digital X-ray imaging system digitalradiographysystem Using digital X-ray image detector technology X-ray imaging devices. Acronym DR system. 3.1.3 imaging plate imagingplate (IP) Using an X-ray storage luminescent material (such as fluorine, barium halide) is made of an X-ray detector plane. 3.1.4 Spatial resolution spatialresolution Under specified measurement conditions, visually discernible predetermined set of graphic line or minimum spatial frequency line pair group unit

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJG 1078-2012_English be delivered?

Answer: Upon your order, we will start to translate JJG 1078-2012_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJG 1078-2012_English with my colleagues?

Answer: Yes. The purchased PDF of JJG 1078-2012_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.