HOME   Cart(12)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (26 Oct 2025)

GB/T 30090-2013 English PDF

US$1129.00 · In stock
Delivery: <= 8 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 30090-2013: Standard guide for temperature electromotive force (emf) tables for non-letter designated thermocouple combinations
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 30090-2013English1129 Add to Cart 8 days [Need to translate] Standard guide for temperature electromotive force (emf) tables for non-letter designated thermocouple combinations Valid GB/T 30090-2013

PDF similar to GB/T 30090-2013


Standard similar to GB/T 30090-2013

GB/T 20730.2   GB/T 19146   GB/T 22065   GB/T 45358   GB/T 43959   GB/T 19665   

Basic data

Standard ID GB/T 30090-2013 (GB/T30090-2013)
Description (Translated English) Standard guide for temperature electromotive force (emf) tables for non-letter designated thermocouple combinations
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard N11
Classification of International Standard 17.200.20
Word Count Estimation 51,538
Quoted Standard GB/T 25475
Adopted Standard ASTM E1751-2009, MOD
Regulation (derived from) National Standards Bulletin No. 25 of 2013
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard specifies the thermocouple temperature no letter code for special purposes - thermal electromotive force (cmf) relationships. This standard applies to special purpose non-letter code thermocouple. This standard does not apply to an extension

GB/T 30090-2013: Standard guide for temperature electromotive force (emf) tables for non-letter designated thermocouple combinations


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Standard guide for temperature electromotive force (emf) tables for non-letter designated thermocouple combinations ICS 17.200.20 N11 National Standards of People's Republic of China No letter designations thermocouple indexing table Standardguidefortemperatureelectromotiveforce (emf) tables Issued on. 2013-12-17 2014-05-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Preface Ⅰ 1 Scope 1 2 Normative references 1 3 Terms and definitions 4 indexing table information 1 4.1 Thermocouple Type 1 4.2 indexing formula 2 4.3 inverse indexing formula 2 Tolerance 2 4.4 Appendix A (informative) seven kinds of thermocouples Introduction 45 Annex B (informative) This standard ASTME1751.2000 46 Differences and Causes Table 1 W - 26 tungsten-rhenium thermocouple emf - temperature dependence (reference junction of 0 ℃) 2 Table 2 PlatinelⅡ thermocouple emf - temperature dependence (reference junction of 0 ℃) 11 Table 3 KP- 0.07 Gold and Iron thermocouple emf - temperature dependence (reference junction of 0 ℃) 16 Table 5- 4 platinum molybdenum molybdenum platinum thermocouple EMF 0.1 - Temperature Relationship (reference junction of 0 ℃) 17 Table 5 platinum and rhodium 40- platinum and rhodium 20 thermocouple emf - temperature dependence (reference junction of 0 ℃) 23 Table 6 nickel-cobalt-nickel-molybdenum 18- 0.8 thermocouple emf - temperature dependence (reference junction of 0 ℃) 29 Table 7 40- Iridium Iridium rhodium thermocouple emf - temperature dependence (reference junction of 0 ℃) 35 Table 8 calculates the temperature of the thermocouple electromotive force as a function of polynomial coefficients 42 Table B.1 This standard ASTME1751.2000 46 Differences and Causes

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules. The Standard is a modified ASTM E1751 use the translation method.2000 No letter code combination of temperature thermocouple thermal emf table (Standardguidefortemperatureelectromotiveforce (EMF) tablesfornon-letterdesignatedthermo- couplecombinations). The standard in the development of the structure of the text made editorial changes. This standard ASTME1751 technical differences are. --- Remove the gold - platinum and platinum - palladium two kinds of thermocouples, the remaining 7 kinds of thermocouple was no difference in the technical characteristics of the original standard; --- Added "2 Normative references" to "Appendix A" "Appendix B"; --- Rewrite "3 Terms and Definitions"; --- Deleted the original "4 Significance and Use" "8 keywords"; --- Original standard "3 Data Sources" "5 thermocouple type" "6 thermal emf - temperature tolerance initial value" of the content of this standard moved Quasi "4 indexing table Information". Also delete the Fahrenheit indexing table indexing formulas and coefficients of each thermocouple. Detailed repair Change the contents of Appendix B. The standard proposed by China Machinery Industry Federation. This standard by the national industrial process measurement and control Standardization Technical Committee (SAC/TC124) centralized. This standard was drafted. Shanghai Industrial Automation Instrument Research Institute, Chongqing Instrument Materials Research Institute, Shanghai Institute of Measurement and Testing Technology, the Sea Automation Instrumentation Co., Ltd., Zhejiang Lunte Electrical Co., Ltd., Zhaoqing Automation Instrumentation Co., Ltd. West Instrument Group Co., Ltd. Company SECRETARY instrument factory, Factory Yueqing City, east China, seventeen Chongqing Sichuan Instrument Co., Ltd., Anhui Rand (Group) Co., Ltd. The main drafters of this standard. Xia Jianfeng, Li Minghua, Chen Lixin, Lu Hong, Song Ping, Wu Galen, Wu Jue, Pu Song, Wu Xinghua, Cao Hong, Wang Fang high. No letter designations thermocouple indexing table

1 Scope

This standard specifies no letter code thermocouples special purpose - thermal electromotive force (emf) relationship. This standard applies to special-purpose non-letter code thermocouple. This standard does not apply to extend or compensating leads.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 25475 Industrial Automation Instrumentation term Thermometers

3 Terms and Definitions

GB/T 25475 and defined by the following terms and definitions apply to this document. 3.1 Matching matchedpairs One pairs of selected positive and negative thermal electrode, constituted by a thermocouple on first use can meet the required temperature - thermal emf relationship And a predetermined tolerance.

4 indexing table information

4.1 Thermocouple Types This standard includes the following indexing table. 1) Platinel original EngelhardCorp.SpecialtyMetalsDiv. Trademarks. 2) KP positive hot electrode type K thermocouples. 3) alloy composition expressed as a percentage by mass, with the exception of gold 0.07 iron, which is an atomic percentage. No. Thermocouple Type Temperature Range Table 1 Tungsten - tungsten rhenium 26 0 ℃ ~ 2315 ℃ Table 2 Platinel1) Ⅱ 0 ℃ ~ 1395 ℃ Table 3 KP2) - Gold and Iron 0.073) -273 ℃ ~ 7 ℃ Table 5- 4 platinum platinum molybdenum molybdenum 0.1 0 ℃ ~ 1600 ℃ Table 5 platinum and rhodium 40- platinum and rhodium 20 0 ℃ ~ 1888 ℃ Table 6 nickel-cobalt-nickel-molybdenum 18- 0.8 -50 ℃ ~ 1410 ℃ Table 7 Iridium Iridium rhodium 40- 0 ℃ ~ 2110 ℃ Polynomial coefficients calculated in Table 8 Temperature (℃) thermocouple electromotive force as a function of the

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 30090-2013_English be delivered?

Answer: Upon your order, we will start to translate GB/T 30090-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically 5 ~ 8 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 30090-2013_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 30090-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Refund Policy     Privacy Policy     Terms of Service     Shipping Policy     Contact Information