|
US$209.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. SN/T 2046-2015: Determination of lead, mercury, chromium, cadmium barium, arsenic, selenium and stibium in plastics and plastic products - Inductively coupled plasma atomic emission spectrometry Status: Valid SN/T 2046: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| SN/T 2046-2015 | English | 209 |
Add to Cart
|
3 days [Need to translate]
|
Determination of lead, mercury, chromium, cadmium barium, arsenic, selenium and stibium in plastics and plastic products - Inductively coupled plasma atomic emission spectrometry
| Valid |
SN/T 2046-2015
|
| SN/T 2046-2008 | English | 319 |
Add to Cart
|
3 days [Need to translate]
|
Plastic and its products in aluminum, mercury, chromium, cadmium, barium, arsenic by inductively coupled plasma atomic emission spectrometry
| Obsolete |
SN/T 2046-2008
|
PDF similar to SN/T 2046-2015
Basic data | Standard ID | SN/T 2046-2015 (SN/T2046-2015) | | Description (Translated English) | Determination of lead, mercury, chromium, cadmium barium, arsenic, selenium and stibium in plastics and plastic products - Inductively coupled plasma atomic emission spectrometry | | Sector / Industry | Commodity Inspection Standard (Recommended) | | Classification of Chinese Standard | G31 | | Classification of International Standard | 83.080.01 | | Word Count Estimation | 9,998 | | Date of Issue | 2015-09-02 | | Date of Implementation | 2016-04-01 | | Older Standard (superseded by this standard) | SN/T 2046-2008 | | Regulation (derived from) | AQSIQ Announcement 2015 - Batch 3 - 103 Industry Standards | | Issuing agency(ies) | General Administration of Customs |
SN/T 2046-2008: Plastic and its products in aluminum, mercury, chromium, cadmium, barium, arsenic by inductively coupled plasma atomic emission spectrometry ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Plastic and its products in aluminum, mercury, chromium, cadmium, barium, arsenic by inductively coupled plasma atomic emission spectrometry
Exit inspection and quarantine industry standard book People's Republic of China
Plastic and its products of lead, mercury, chromium, cadmium,
Barium, arsenic was measured by Inductively Coupled
Plasma atomic emission spectrometry
Posted 2008-04-29
2008-11-01 implementation
People's Republic of China
The State Administration of Quality Supervision, Inspection and Quarantine released
Foreword
The Standard Appendix A, Appendix B is an informative annex.
This standard is proposed and managed by the National Certification and Accreditation Administration Committee.
This standard by the People's Republic of China Guangdong CIQ is responsible for drafting, Shenzhen People's Republic of China Entry-Exit Inspection and Quarantine
Bureau, Xiamen People's Republic of China participated in the drafting Exit Inspection and Quarantine.
The main drafters of this standard. Liuchong Hua, Zhong Zhiguang, Mu Junze, Zeng Jiaxin Huang Li Na, Zhang Haifeng, Huang, Lee Jun, Xiao Dahui.
This standard is the first release of the entry-exit inspection and quarantine industry standards.
Plastic and its products of lead, mercury, chromium, cadmium,
Barium, arsenic was measured by Inductively Coupled
Plasma atomic emission spectrometry
Warning. Use of this standard should have practical experience in regular laboratory work. This standard does not point out all possible security asked
question. Users have the responsibility to take appropriate safety and health practices and to ensure compliance with the conditions of the relevant provisions of the State.
1 Scope
This standard specifies the inductively coupled plasma atomic and plastic products (excluding plastic polyvinyl fluoride) Lead (Pb) emission spectrometry, mercury
(Hg), chromium (Cr), cadmium (Cd), barium (Ba) and arsenic (As) content approach.
This standard applies to plastics and articles thereof (except plastic polyvinyl fluoride) Lead (Pb), mercury (Hg), chromium (Cr), cadmium (Cd), barium (Ba) and arsenic
(As) measurement.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 602 Determination of impurities in chemical reagents prepared standard solution (GB/T 602-2002, ISO 6353-1. 1982, NEQ) with
GB/T 6379.2 measurement methods and results of Accuracy (trueness and precision) - Part 2. Determine the standard measurement method to repeat
Of the basic methods of reproduction (GB/T 6379.2-2004, ISO 5725-2.1994, IDT)
GB/T 6682 analytical laboratory use specifications and test methods (GB/T 6682-1992, neq ISO 3696. 1987)
3 Method summary
A sample was concentrated nitric acid, hydrogen peroxide, a mixed solvent tetrafluoroborate by microwave digestion solution by inductively coupled plasma after digestion
Atomic emission spectrometer to determine the content of each element according to the working curve.
4 Reagents
Unless otherwise indicated in the analysis using only the gifted class pure reagents, test water should be consistent with GB/T 6682 provisions of secondary water requirements.
4.1 nitric acid (ρ = 1.42g/mL).
4.2 nitric acid (5 + 95).
4.3 Hydrogen peroxide (ρ = 1.10g/mL).
4.4 tetrafluoroboric acid solution (40%).
4.5 lead, mercury, chromium, cadmium, barium and arsenic standard stock solution (1000mg/L). according to GB/T 602 formulated or direct purchase of certified reference materials.
4.6 Nitrate - tetrafluoroborate mixed solution. Measure 100mL nitric acid (4.1), and slowly poured into 870mL water and then weighed 30mL tetrafluoroborate
Acid solution (4.4) and mix together to give nitric acid - tetrafluoroborate mixed solution.
4.7 lead, chromium, cadmium, barium and arsenic mixed standard stock solution (100μg/mL). Pipette 10.0mL lead, chromium, cadmium, barium and arsenic solution (4.5)
In 100mL volumetric flask, dilute to the mark with nitric acid (4.2) and mix. This solution 1mL contain lead, chromium, cadmium, barium and arsenic each 100μg.
4.8 mercury standard stock solution (100μg/mL). draw 10.0mL mercury solution (4.5) in 100mL flask, diluted with nitric acid (4.2) to
Volume, and mix. This solution 1mL containing mercury 100μg.
4.9 lead, chromium, cadmium, barium and arsenic series of standard solution. Pipette 0mL, 1.0mL, 2.0mL, 5.0mL, 10.0mL lead, chromium,
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of SN/T 2046-2015_English be delivered?Answer: Upon your order, we will start to translate SN/T 2046-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of SN/T 2046-2015_English with my colleagues?Answer: Yes. The purchased PDF of SN/T 2046-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version SN/T 2046-2015?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version SN/T 2046-2015 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|