HOME   Cart(1)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

JJF 1121-2004 English PDF

US$319.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJF 1121-2004: Calibration Specification for Hand-hold pitch Comparator
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJF 1121-2004English319 Add to Cart 3 days [Need to translate] Calibration Specification for Hand-hold pitch Comparator Valid JJF 1121-2004

PDF similar to JJF 1121-2004


Standard similar to JJF 1121-2004

JJG 1114   JJF 1280   JJF 1126   JJG 1128   JJG 1127   JJG 1121   

Basic data

Standard ID JJF 1121-2004 (JJF1121-2004)
Description (Translated English) Calibration Specification for Hand-hold pitch Comparator
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A52
Classification of International Standard 17.040
Word Count Estimation 12,12
Date of Issue 2004-06-04
Date of Implementation 2004-12-01
Older Standard (superseded by this standard) JJG 79-1982
Quoted Standard JJF 1001-1998; JJF 1059-1999; GB/T 10095.1-2001; GB/Z 18620.1-2002
Issuing agency(ies) State Administration of Quality Supervision, Inspection and Quarantine
Summary This standard applies to indexing is 1��m, modulus of 2mm ~ 15mm and l0mm ~ 16mm pitch compare handheld instrument calibration.

JJF 1121-2004: Calibration Specification for Hand-hold pitch Comparator

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification for Hand-hold pitch Comparator National Metrology Technical Specification of the People's Republic Handheld Pitch Comparator Calibration Specifications Released on June.2004 Implementation of.2004-12-01 The General Administration of Quality Supervision, Inspection and Quarantine issued Hand-held pitch comparator Calibration specification Arator Replace JJG79-1982 This specification was approved by the General Administration of Quality Supervision, Inspection and Quarantine on June 4,.2004, and Implemented on December 1,.2004. Focal Point. National Geometric Length Measurement Technical Committee Drafting unit. Dongfeng Motor Corporation Metrology Institute This specification is interpreted by the focal point Drafters of this specification. Zheng Xu (Dongfeng Motor Corporation Metrology Institute)

table of Contents

1 Scope (1) 2 Citations (1) 3 Overview (1) 4 Measurement characteristics (2) 4.1 indicator table (2) 4.2 indication repeatability (2) 4.3 indication error (2) 5 Calibration conditions (2) 5.1 Environmental conditions (2) 5.2 Calibration items and standards (2) 6 Calibration items and calibration methods (2) 6.1 Indicator Table (2) 6.2 indication repeatability (2) 6.3 indication error (3) 7 Expression of calibration results (3) 8 re-study interval (3) Appendix A Calibration Certificate Contents (4) Appendix B Evaluation of Measurement Uncertainty of Handset Pitch Comparator Error (5) Handheld Pitch Comparator Calibration Specifications

1 Scope

This specification applies to hand-held pitch ratios with a divisional value of 1 μm and a modulus of 2 mm to 15 mm and 10 mm to 16 mm. Comparison with the instrument.

2 Citations

The provisions contained in the following documents constitute provisions of this specification by reference in this specification. Publication of this specification The version shown is valid. All standards, specifications or procedures will be revised and all parties using this specification should Use the possibility of the latest version of the following literature. JJF 1001-1998 General measurement terms and definitions JJF 1059-1999 Measurement Uncertainty Evaluation and Representation GB/T 10095.1-2001 Involute cylindrical gear precision - Part 1. Determining the deviation of the flanks Righteous allowable value GB/Z 18620.1-2002 Specification for the inspection of cylindrical gears - Part 1

3 Overview

The handheld pitch comparator uses the relative measurement principle to measure the adjacent pitch of the external mesh spur gear and helical gear Instrument for accumulating errors in error and pitch. The shape of a typical hand-held pitch comparator is shown in Figure 1 and Figure 2. Figure 1 Figure 2

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJF 1121-2004_English be delivered?

Answer: Upon your order, we will start to translate JJF 1121-2004_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJF 1121-2004_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1121-2004_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.