US$329.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. JJG 1121-2015: Verification Regulation of Vortex Precession Flowmeters Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJG 1121-2015 | English | 329 |
Add to Cart
|
3 days [Need to translate]
|
Verification Regulation of Vortex Precession Flowmeters
| Valid |
JJG 1121-2015
|
PDF similar to JJG 1121-2015
Basic data Standard ID | JJG 1121-2015 (JJG1121-2015) | Description (Translated English) | Verification Regulation of Vortex Precession Flowmeters | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A53 | Classification of International Standard | 17.120 | Word Count Estimation | 14,194 | Date of Issue | 2015-12-07 | Date of Implementation | 2016-03-07 | Older Standard (superseded by this standard) | JJG 198-1994 | Quoted Standard | JJF 1004; GB 3836; GB 4208; GB 50251; GB/T 13609; GB/T 13610; GB/T 17747.2-2011; OIML R137-1&2-2012; GB 17820-2012 | Regulation (derived from) | ?AQSIQ 2015 Nian (No.148) | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This standard is applicable to the first verification, follow-up verification and inspection during use of the swirl vortex flowmeter. |
JJG 1121-2015: Verification Regulation of Vortex Precession Flowmeters---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Verification Regulation of Vortex Precession Flowmeters
National Metrological Verification Regulation of the People's Republic of China
Rotary vortex flowmeter
2015-12-07 released
2016-03-07 implementation
State Administration of Quality Supervision, Inspection and Quarantine issued
Test procedure for rotary vortex flowmeter
Replacing JJG 198-1994
In the vortex into the vortex flowmeter part
Responsible Unit. National Traffic Capacity Measurement Technical Committee
The main drafting unit. China Institute of Metrology
Beijing Institute of Metrology and Testing
Participated in the drafting unit. Xinjiang Metrology and Testing Institute
Days letter Instrument Group Co., Ltd.
Zhejiang Cangnan Instrument Factory
Zhejiang Fu Ma Instrument Co., Ltd.
Beijing Fischer Porter Instrument Co., Ltd.
This procedure entrusts the National Flow Capacity Measurement Technical Committee to explain
The main drafters of this procedure.
Duan Huiming (China Institute of Metrology)
Yang Youtao (Beijing Institute of Metrology and Measurement Science)
Participate in the drafters.
Li Hao (Xinjiang Institute of Measurement and Testing)
Ye Peng (days letter Instrument Group Co., Ltd.)
Yin Xingjing (Zhejiang Cangnan Instrument Factory)
Zheng Yingming (Zhejiang Fu Ma Instrument Co., Ltd.)
Wang Yue sound (Beijing Feishipote Instrument Co., Ltd.)
table of Contents
Introduction (II)
1 Scope (1)
2 References (1)
3 terms and units of measurement (1)
3.1 Terms (1)
3.2 Unit of measurement (1)
4 Overview (1)
4.1 Use and working principle (1)
4.2 Structure (2)
5 Measurement performance requirements (2)
5.1 Accuracy class and maximum permissible error (2)
5.2 Repeatability (3)
6 General technical requirements (3)
6.1 Appearance (3)
6.2 Sealing (3)
7 Metering device control (3)
7.1 Test conditions (3)
7.2 Verification and verification methods (4)
7.3 Verification Result Processing (6)
7.4 Verification cycle (6)
Appendix A Certificate of Verification/Verification Result Page Format (7)
Appendix B Using Gas Flowmeter K Factor to Calculate the Accumulated Error of the Model Condition (8)
Introduction
This procedure replaces the JJG 198-1994 part of the precession vortex flowmeter.
This procedure in accordance with JJF1002-2010 "national measurement procedures for the preparation of rules", according to JJF1004 "flow
Metrological terminology and definitions ", GB 3836.1-2010" Explosive atmospheres Part 1. General requirements for equipment
GB 3836.2-2010 "Explosive atmospheres Part 2. Equipment protected by flameproof enclosure" d "
GB 3836.3-2010 "Explosive atmospheres Part 3. Equipment protected by increased safety" e ", GB 4208-
2008 "enclosure protection class (IP code)", GB 50251 "gas pipeline engineering design specifications", GB/T 13609
"Natural Gas Sampling Guidelines", GB/T 13610 "Composition Analysis of Natural Gas Gas Chromatography", GB/T 17747.2-
2011 "Calculation of natural gas compression factor Part 2. Calculation by molar composition", International Organization of Legal Metrology
(OIML) International Recommendation R137-1
Eddy current meter technical level and industry status to be revised. And JJG 198-1994 "speed flowmeter" in the
The "precession vortex flowmeter" section compared to the main changes are as follows.
--- Added "Introduction, reference documents, terms and units of measurement";
--- cancel the "0.1, 0.2, 0.5 and 4.0 level of accuracy";
--- introduced the "boundary flow qt" concept, in the same accuracy level, respectively, by qt ≤ q ≤ qmax and qmin ≤
--- cancel 0.7qmax test flow point;
--- Amend the "Verification Certificate/Verification Result Notice Page Format" appendix.
Prerequisites of this Code Release.
--- "JJG 198-1994" speed flowmeter "in the" precession vortex flowmeter "part;
--- JJG 464-1986 "Rotary vortex flow transmitter" (Trial).
Test procedure for rotary vortex flowmeter
1 Scope
This procedure applies to the first test of the precession vortex flowmeter (hereinafter referred to as flowmeter), subsequent verification and use
an examination.
2 reference file
The provisions contained in the following documents constitute the provisions of this Code by reference.
JQF1004 flow meter noun terms and definitions
Electrical equipment for explosive atmospheres GB 3836
GB 4208 enclosure protection class (IP code)
Code for design of gas transmission pipeline GB 50251
Guide for sampling of natural gas GB/T 13609
GB/T 13610 Natural Gas Component Analysis - Gas Chromatography
GB/T 17747.2-2011 Calculation of natural gas compression factor - Part 2. Calculation of molar composition
Natural gas
OIMLR137-1
Any reference to the date of the document, only the date of the version of the application of this procedure; those who do not note the date of the reference file,
The latest version (including all amendments) applies to this procedure.
3 terms and units of measurement
3.1 terminology
In addition to the terms and definitions of JJF1004, this procedure uses the following terms.
3.1.1 Piezoelectric Sensors piezoelectricsensor
Sensitive elements that detect vortex precession frequencies.
3.1.2 body body of the body
Install the vortex generator, piezoelectric sensors and rectifiers and other components, and with the contraction and diffusion section of the pipe section.
3.1.3 K-factor K-Coefficient
When the volume of fluid flows through the flow meter, the number of pulses emitted by the flowmeter.
3.1.4 standard volume flow normalized volumetricflowrate
The temperature is 20 ℃, the pressure is 101.325kPa standard state of the volume flow.
3.2 Units of measurement
Flowmeter shows the cumulative flow unit. cubic meter, symbol m3; l, symbol L (dm3).
Flowmeter shows instantaneous flow unit. cubic meter per hour, symbol m3/h.
4 Overview
4.1 Use and working principle
Flow meter for gas, liquid flow measurement.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJG 1121-2015_English be delivered?Answer: Upon your order, we will start to translate JJG 1121-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJG 1121-2015_English with my colleagues?Answer: Yes. The purchased PDF of JJG 1121-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|