HOME Cart(0) Quotation About-Us Policies PDFs Standard-List
www.ChineseStandard.net Database: 221581 (27 Mar 2026)
Path: Home > GB/T > Page122 > GB/T 21739-2025 || Home > Standard_List > GB/T > Page122 > GB/T 21739-2025

GB/T 21739-2025 PDF English

Price & Delivery

US$1559.00 ยท In stock
Delivery: <= 10 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 21739-2025: Safety rules for the construction and installation of home lifts
Status: Valid

GB/T 21739: Evolution and historical versions

Std IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)Status
GB/T 21739-2025English1559 Add to Cart 10 days [Need to translate] Safety rules for the construction and installation of home lifts Valid
GB/T 21739-2008English1389 Add to Cart 10 days [Need to translate] Rules for the construction and installation of home lifts Valid

Standard similar to GB/T 21739-2025

GB/T 24478 | GB/T 24807 | GB/T 24476 | GB/T 24477 | GB/T 18775 |

Basic data

Standard ID GB/T 21739-2025 (GB/T21739-2025)
Description (Translated English) Safety rules for the construction and installation of home lifts
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard Q78
Classification of International Standard 91.140.90
Word Count Estimation 78,740
Date of Issue 2025-08-29
Date of Implementation 2026-03-01
Older Standard (superseded by this standard) GB/T 21739-2008
Issuing agency(ies) State Administration for Market Regulation; Standardization Administration of China

GB/T 21739-2025: Safety rules for the construction and installation of home lifts

---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT21739-2025
ICS 91.140.90 CCSQ78 National Standards of the People's Republic of China Replaces GB/T 21739-2008 Safety Specifications for the Manufacturing and Installation of Home Elevators Published on 2025-08-29 Implemented on 2026-03-01 State Administration for Market Regulation The State Administration for Standardization issued a statement.

Table of Contents

Preface III Introduction VII 1.Scope 1 2 Normative References 1 3.Terms and Definitions 2 4.Safety requirements and/or protective measures 3. 5.Verification of safety requirements and/or protective measures 45 6.Information 52 Appendix A (Informative) List of Major Hazards 55 Appendix B (Normative) Type Test Procedure for Conformity Certification of Safety Components Driven by Screws and Nuts in Home Elevators 58 Appendix C (Normative) Table 61 of Electrical Safety Devices Appendix D (Informative) Technical Conformity Documents 63 Appendix E (Informative) Regular Inspection and Maintenance 64 References 65

Foreword

This document complies with the provisions of GB/T 1.1-2020 "Standardization Work Guidelines Part 1.Structure and Drafting Rules of Standardization Documents". Drafting. This document replaces GB/T 21739-2008 "Code for Manufacturing and Installation of Home Elevators". Compared with GB/T 21739-2008, except for the structure... Aside from adjustments and editorial changes, the main technical changes are as follows. ---The scope of application has been changed, and the content and requirements applicable to gear and rack driven home elevators have been removed (see Chapter 1,.2008). Chapter 1 (Year Edition) ---The term "building in use" has been changed to "existing building," and its definition has been revised (see 3.2,.2008 edition). ---The term and definition of "competent personnel" have been removed (see 3.3 in the.2008 edition); ---Added requirements for signs, markings, warnings, and operating instructions (see 4.1.2); ---Performance requirements under fire conditions have been changed (see 4.3, 4.4 in the.2008 edition); ---Noise requirements have been added (see 4.4); ---The protection requirements against harmful external influences have been removed (see 4.12 in the.2008 edition); ---The protection rating requirement for outdoor use has been removed (see 4.13 of the.2008 edition); ---The minimum channel requirement has been removed (see 4.14 in the.2008 version); ---The requirements for shafts and machine rooms have been changed (see 4.5.1.2, 5.1 in the.2008 version); ---Increased ventilation requirements for shafts and machine spaces (see 4.5.1.3); ---Added lighting requirements for shaft and machine space (see 4.5.1.4); ---Added requirement to install lighting control switches within the machine space (see 4.5.1.5.2); ---Added requirements for equipment hoisting (see 4.5.1.6); ---The strength and surface requirements for walls, floors, and ceilings have been changed (see 4.5.1.7 and 4.5.1.8, 5.7 in the.2008 edition); ---Increased access requirements for shafts and machine spaces (see 4.5.2); ---Requirements for access doors, access trapdoors, and maintenance doors have been changed (see 4.5.3, 5.8 in the.2008 edition); ---Added warning sign requirements for doors, trapdoors, and passageway doors leading to machine spaces (see 4.5.4); ---The sealing requirements for the shaft have been changed (see 4.5.5.2, 5.2.2 and 5.6.2.2 in the.2008 version); ---The structural requirements for the landing door and hoistway wall facing the car entrance of home elevators with car doors have been changed (see 4.5.5.3,.2008 version). 5.6.2.1.3 and 12.1.1); ---The protection requirements for the space below the shaft have been changed (see 4.5.5.5, 5.5 in the.2008 version); ---Added protection requirements for areas operating under heavy or counterweight conditions (see 4.5.5.6); ---The top-level space requirement has been changed (see 4.5.5.8, version 5.3 of the.2008 edition); ---The pit space requirements have been changed (see 4.5.5.9, 5.4 in the.2008 version); ---Added warnings and instructions regarding machine space requirements (see 4.5.6.2); ---Added requirements for machines to be located in the computer room (see 4.5.6.3); ---Increased requirements for machine protection, operating space, and marking within the shaft (see 4.5.6.4.1); ---Increased the size requirements for the working area within the shaft (see 4.5.6.4.2); ---Added requirements for the working area inside the car (see 4.5.6.4.3); ---The requirements for the machine's working area outside the hoistway have been changed (see 4.5.6.5.2, 4.3.2.3 in the.2008 version); ---The requirements for emergency and test operation equipment have been changed (see 4.5.6.6, 4.3.2.1 of the.2008 version); ---The ramp setup requirements have been changed (see 4.6.4, 6.4.6 in the.2008 version); ---The horizontal distance requirement between the manual car door sill and the landing door sill has been changed (see 4.6.5, 12.1.1.2 in the.2008 version); ---The mechanical strength requirements for landing doors and car doors have been changed (see 4.6.6.2, 6.4.7 and 7.13.2.7 in the.2008 edition); ---The requirements for powered doors have been changed (see 4.6.7.2, 6.4.3.4 and 6.4.10 in the.2008 version); ---Added a requirement for the door to open in reverse during the closing process (see 4.6.7.4); ---Added requirements for localized lighting at each floor (see 4.6.8.1); ---The car's instructions here have been modified (see 4.6.8.2.1, 6.4.8 in the.2008 version); ---The unlocking zone requirements have been changed (see 4.6.9.1, version 6.5.1 from.2008); ---The type testing requirements for landing door locking devices have been revised (see 4.6.10.1, 15.1.6 of the.2008 edition); ---Added type testing requirements for car door locking devices (see 4.6.10.2); ---Added requirements for the position of the triangular unlocking device (see 4.6.10.3.2); ---Added a common requirement for devices confirming the locked and closed status of landing doors (see 4.6.11); ---The requirements for mechanically connected multi-sliding landing doors have been changed (see 4.6.12, 6.8 in the.2008 edition); ---The requirements for mechanically connected multi-sliding or folding car doors have been changed (see 4.6.15, 7.13.2.9 of the.2008 edition); ---The requirements for opening the car doors have been changed (see 4.6.16, 7.13.2.4 and 7.13.2.10 in the.2008 version); ---The requirements for calculating the effective area of the elevator car in home elevators with doors have been revised (see 4.7.2.1.3, 7.3.2 of the.2008 version); ---The requirements for information displayed inside the car have been changed (see 4.7.2.2, 16.2.1.1 in the.2008 version); ---The mechanical strength requirements for the car walls have been changed (see 4.7.3.4, 7.5.2 in the.2008 version); ---The handrail height requirements for using glass car walls have been changed (see 4.7.3.6, 7.5.3.1 in the.2008 version); ---Added requirement for extendable footplates (see 4.7.5.3); ---The mechanical strength requirements for foot protectors have been changed (see 4.7.5.4, 7.8.3 in the.2008 version); ---The mechanical strength requirements for the car roof have been changed (see 4.7.6.1, 7.4.2 in the.2008 version); ---The installation requirements for the car roof kickboard have been changed (see 4.7.6.2, 7.4.4.2 in the.2008 version); ---The mechanical strength requirements for the car roof guardrail have been increased [see 4.7.6.5e]; ---The handrail requirements have been changed (see 4.7.9, 7.10 in the.2008 version); ---The requirements for folding chairs have been changed (see 4.7.10, 7.11 in the.2008 version); ---The ventilation requirements for home elevators with car doors have been changed (see 4.7.11, 7.6 in the.2008 edition); ---The requirements for car lighting have been changed (see 4.7.12.1 and 4.7.12.3, and 7.12.1 and 7.12.3 in the.2008 edition); ---The requirements for emergency lighting in the car have been changed (see 4.7.12.4, 7.12.5 in the.2008 edition); ---The requirement for covering ropes and covering straps as suspension devices has been added (see 4.8); ---The requirement for drive sprockets has been removed (see 13.5.3.3 in the.2008 version); ---The traction requirements have been changed (see 4.8.3, version 13.6.6 of the.2008 edition); ---The protection requirements for traction sheaves, pulleys, sprockets, speed governors, and tensioners have been changed (see 4.8.6.1, 13.1.7.1 of the.2008 edition); ---Added requirements for anti-detachment devices (see 4.8.6.3); ---The provision regarding "clamping devices" in the mechanical anti-settlement measures for hydraulically driven home elevators has been deleted (see section 13.8.11.2 of the.2008 edition). 13.8.11.3); ---The requirement for safety clamp braking distance has been removed (see 10.1.1.3 in the.2008 version); ---Added requirements for a car accidental movement protection device (see 4.9.1.2, 4.9.1.3 and 4.9.7); ---The safety clamp release requirements have been changed (see 4.9.2.1.4, 10.1.3 in the.2008 version); ---The requirements for the structure and triggering method of the safety clamp have been changed (see 4.9.2.1.6.4, 10.1.2.1 in the.2008 version); ---The speed limiter triggering requirements have been changed (see 4.9.2.2.1, version 10.2 of the.2008 edition); ---Added requirements for triggering suspension failure (see 4.9.2.2.2); ---Added safety rope triggering requirements (see 4.9.2.2.3); ---The requirements for rupture valves have been changed (see 4.9.3, 13.8.7.5 of the.2008 version); ---Throttle valve requirements have been changed (see 4.9.4, 13.8.7.6 of the.2008 version); ---The requirements for the ratchet mechanism have been changed (see 4.9.5, 13.8.11.4 in the.2008 version); ---The requirements for the car's upward overspeed protection device have been changed (see 4.9.6, 13.6.7 of the.2008 version); ---The requirements for the forces acting on the guide rail and the method for calculating the guide rail have been changed (see 4.10, 9.4.3 in the.2008 edition); ---Added requirements regarding the placement of obstacles in the pit when the buffer is fixed to the car or counterweight (see 4.11.1.1); ---The requirement for top-mounted buffers has been changed (see 4.11.2,.2008 version 11.2), adding rows for car and counterweight buffers. Process requirements (see 4.11.2); ---Added requirements for protection of accessible rotating parts (see 4.12.1.6); ---The speed deviation requirement has been changed (see 4.12.2, 13.1.8 of the.2008 version); ---The braking force requirements for electromechanical brakes have been changed, and monitoring requirements have been added (see 4.12.3.2.2.1, 13.2.2.1 in the.2008 version); ---Added requirements for cutting off the power supply to the brake [see 4.12.3.2.2.3a)2) and 4.12.3.2.2.3a)3)]; ---The requirement for continuously manually opening the brake has been changed (see 4.12.3.2.2.7, 13.2.2.2 in the.2008 version); ---Added a requirement to move the car to a nearby floor when manually releasing the brake (see 4.12.3.2.2.9); ---The requirements for motor power supply and control have been changed (see 4.12.3.4, 14.8 of the.2008 version); ---Requirements for hydraulically driven home elevators have been revised (see 4.12.4, 13.8 of the.2008 edition); ---Electromagnetic compatibility requirements have been changed (see 4.13.1.1.3, 14.10 of the.2008 version); ---Added requirements for electrical operators (see 4.13.1.1.4); ---Added requirements for the location of control devices (see 4.13.1.1.5); ---Added requirements for component temperature and accessible equipment temperature limits (see 4.13.1.1.6); ---Added electric shock protection requirements (see 4.13.1.2); ---The insulation resistance requirement has been changed (see 4.13.1.3, 14.4.2.9 in the.2008 edition); ---The requirements for contactors and contactor-type relays have been changed (see 4.13.3, 14.7 of the.2008 edition); ---The protection requirements for electrical equipment have been changed (see 4.13.4, 14.13.1 in the.2008 edition); ---Added requirements for the location of the main switch (see 4.13.5.3); ---Added a requirement for a power cut-off switch for each input power supply (see 4.13.5.3); ---Electrical wiring requirements have been changed (see 4.13.6, 14.4.1.2 of the.2008 version); ---Added requirements for power control of lighting and sockets (see 4.13.8); ---The requirements for electrical safety devices have been changed (see 4.14, 14.9 and 14.12 in the.2008 edition); ---Added requirements for leveling and re-leveling control when doors are not closed or locked (see 4.15.1.3); ---The maintenance operation control requirements have been changed (see 4.15.1.4, 14.17.2 of the.2008 version); ---The emergency electric operation control requirements have been changed (see 4.15.1.5, 14.17.3 of the.2008 version); ---Added requirements for bypass devices for landing doors and car doors (see 4.15.1.6); ---Added requirements to prevent the home elevator from operating normally in the event of a door contact circuit failure (see 4.15.1.7); ---The requirements for electrical anti-settlement systems in hydraulically driven home elevators have been changed (see 4.15.1.8, 14.17.4 of the.2008 edition); ---Added requirements for automatic rescue operation devices (see 4.15.1.9); ---The requirements for the stopping device have been changed (see 4.15.1.10, 14.15.5 in the.2008 version); ---The limit switch requirements have been changed (see 4.15.2, 14.15.6 in the.2008 version); ---The priority requirements have been changed (see 4.15.4, 14.15.3 and 14.15.4 from the.2008 edition); ---Additional requirements for battery power have been changed (see 4.16, 14.14 in the.2008 edition); ---Added technical conformity documentation requirements (see 5.1); ---Design verification requirements have been added (see 5.2); ---The pre-delivery inspection requirements have been changed (see 5.3, 15.2.1 of the.2008 version); ---The requirements for the user and maintenance manual have been changed (see 6.2, 16.4 of the.2008 edition).
GB/T 21739-2025 English cover page

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 21739-2025_English be delivered?

Answer: Upon your order, we will start to translate GB/T 21739-2025_English as soon as possible, and keep you informed of the progress. The lead time is typically 6 ~ 10 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 21739-2025_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 21739-2025_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 21739-2025?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 21739-2025 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
Terms of Service | Contact Information | Privacy Policy | Refund Policy | Shipping Policy