US$229.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. YY/T 0095-2013: Calcium tungstate middle speed intensifying screens for medical use Status: Valid YY/T 0095: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
YY/T 0095-2013 | English | 229 |
Add to Cart
|
3 days [Need to translate]
|
Calcium tungstate middle speed intensifying screens for medical use
| Valid |
YY/T 0095-2013
|
YY/T 0095-2004 | English | 399 |
Add to Cart
|
3 days [Need to translate]
|
Calcium tungstate middle speed intensifying screens for medical use
| Obsolete |
YY/T 0095-2004
|
YY 0095-1992 | English | 199 |
Add to Cart
|
2 days [Need to translate]
|
(Medical speed calcium tungstate intensifying screens)
| Obsolete |
YY 0095-1992
|
PDF similar to YY/T 0095-2013
Basic data Standard ID | YY/T 0095-2013 (YY/T0095-2013) | Description (Translated English) | Calcium tungstate middle speed intensifying screens for medical use | Sector / Industry | Medical Device & Pharmaceutical Industry Standard (Recommended) | Classification of Chinese Standard | C43 | Classification of International Standard | 11.040.50 | Word Count Estimation | 10,197 | Older Standard (superseded by this standard) | YY/T 0095-2004 | Quoted Standard | GB/T 191-2008; GB/T 2828.1-2012; GB/T 2829-2002; GB/T 9969-2008; GB/T 10149-1988 | Regulation (derived from) | State Food and Drug Administration Notice No. 36 of 2013; industry standard for filing Notice 2013 No. 12 (No. 168 overall) | Issuing agency(ies) | State Food and Drug Administration | Summary | This standard specifies the speed calcium tungstate intensifying screens for medical (hereinafter referred to as intensifying screens) terminology, requirements, test methods, inspection rules, signs, labels, instruction manual and packaging, transportati |
YY/T 0095-2013: Calcium tungstate middle speed intensifying screens for medical use---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calcium tungstate middle speed intensifying screens for medical use
ICS 11.040.50
C43
People's Republic of China pharmaceutical industry standards
Replacing YY/T 0095-2004
Medical speed calcium tungstate intensifying screen
Issued on. 2013-10-21
2014-10-01 implementation
China Food and Drug Administration released
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
Instead of the standard YY/T 0095-2004 "speed calcium tungstate intensifying screens for medical," compared with the YY/T 0095-2004 major changes
as follows.
--- Modify the standard reference file's number;
--- 5.3.2 sensitization modified coefficient test methods;
--- Modify the limiting resolution 5.4.2 Test Method.
Please note that some of the content of this standard may involve patents. The standard release mechanism does not assume the responsibility to identify these patents.
This standard was proposed by the China Food and Drug Administration.
This standard by the National Standardization Technical Committee on Medical Electrical medical X-ray equipment and utensils Standardization Technical Committee (SAC /
TC10/SC1) centralized.
This standard was drafted. Liaoning Provincial Medical Device Testing.
The main drafters of this standard. Qu Yan.
This standard supersedes previously issued as follows.
--- WS2-145-1965, WS2-145-1982;
--- YY/T 0095-1992, YY/T 0095-2004.
Medical speed calcium tungstate intensifying screen
1 Scope
This standard specifies the speed of medical calcium tungstate intensifying screen (hereinafter referred to as intensifying screen) terminology, requirements, test methods, inspection rules, marking,
Labels, instruction manual and packaging, transportation and storage.
This standard applies to X-ray intensifying screens used in photography.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 191-2008 Packaging - Pictorial signs
GB/T 2828.1-2012 count batch inspection sampling plan Sampling procedures for inspection by acceptance quality limit (AQL) retrieval
GB/T 2829-2002 periodic inspection Sampling procedures and tables (suitable for process stability test)
GB/T 9969-2008 General Industrial Product Manual
GB/T 10149-1988 X-ray equipment for medical terminology and symbols
3 Terms and Definitions
GB/T 10149-1988 define the following terms and definitions apply to this document.
3.1
Limiting resolution limitingresolution
The template smallest distance between two adjacent pairs as a distinguishable image information imaged on the ability of the film to the resolution. Intensifying screen
Limiting resolution is the use of intensifying screens for resolution test card image on the X-ray film, every millimeter maximum linear human eye can distinguish logarithm.
3.2
Emission spectrum emissionspectrum
Emission energy distribution by wavelength or frequency, said emission spectrum.
3.3
Sensitizing factor intensifyingfactor
Under the conditions of use and do not use the intensifying screen, to X-ray film was exposed at an exposure amount of the film density value 1
(The mAs) ratio.
4 Requirements
4.1 Working conditions
Intensifying screen should meet the following conditions.
Before a) can be equipped with blue or green film, the film is placed in front of the light-emitting surface opposite intensifying screen between the rear panel, and close to the intensifying screen, after
Screen panel, X-ray tube is aligned perpendicular to the reference axis intensifying screen on the back of the front panel;
b) at room temperature. 5 ℃ ~ 30 ℃;
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YY/T 0095-2013_English be delivered?Answer: Upon your order, we will start to translate YY/T 0095-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of YY/T 0095-2013_English with my colleagues?Answer: Yes. The purchased PDF of YY/T 0095-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version YY/T 0095-2013?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YY/T 0095-2013 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|