US$759.00 ยท In stock Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email. SB/T 10480-2008: Technical rule of disassembly/installation and maintenance for room air-conditioner Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| SB/T 10480-2008 | English | 759 |
Add to Cart
|
5 days [Need to translate]
|
Technical rule of disassembly/installation and maintenance for room air-conditioner
| Valid |
SB/T 10480-2008
|
PDF similar to SB/T 10480-2008
Basic data | Standard ID | SB/T 10480-2008 (SB/T10480-2008) | | Description (Translated English) | Technical rule of disassembly/installation and maintenance for room air-conditioner | | Sector / Industry | Domestic Trade Industry Standard (Recommended) | | Classification of Chinese Standard | A20 | | Classification of International Standard | 03.080.01 | | Word Count Estimation | 29,253 | | Date of Issue | 2008-09-27 | | Date of Implementation | 2009-03-01 | | Quoted Standard | GB 156; GB/T 700; GB 1002; GB/T 3187-1994; GB/T 3608; GB/T 3787; GB 4706.1; GB 4706.32-2004; GB/T 5013; GB/T 5023; GB 5306; GB/T 7373; GB/T 7725-2004; GB 8877; GB 9237; GB/T 12325; GB 13955; GB 17790-1999; GB 19210; GB 50169; AQ 7004; HG 23014; SB/T 10349-2002 | | Regulation (derived from) | ?Ministry of Commerce Announcement 2008 No.72 | | Issuing agency(ies) | Ministry of Commerce of the People's Republic of China | | Summary | This standard specifies the technical requirements for household and similar purposes in the use of room air conditioners workplace removal/installation and maintenance services specified places, operating specifications and quality evaluation methods. This standard applies to the use of air-cooled condenser, Hermetic compressor-motor. For confined space air conditioning or similar purposes and a controllable speed (outdoor unit) trailer and more (Part of the indoor unit > type room air conditioner. |
SB/T 10480-2008: Technical rule of disassembly/installation and maintenance for room air-conditioner ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Technical rule of disassembly/installation and maintenance for room air-conditioner
ICS 03.080.01
A20
Record number. 25124-2008
People's Republic of China domestic trade industry standard
Room air conditioner disassembly and assembly
Technical specification for repair service
Released on.2008-09-27
2009-03-01 implementation
Published by the Ministry of Commerce
Content
Foreword III
1 Scope 1
2 Normative references 1
3 Terms and Definitions 1
4 Disassembly and Repair Service Technical Requirements 4
5 Disassembly work procedure 8
6 Installation procedure 8
7 Maintenance procedures 10
8 Repair operation procedures 11
9 Technical support for professional repairs 12
10 Quality Inspection and Evaluation 13
Appendix A (informative) Installation and maintenance service quality assurance period classification 17
Appendix B (informative) Technical aspects of the installation program 18
Appendix C (informative) Installation Service Agreement Example 21
Appendix D (informative) Notes on daily use 22
Appendix E (informative) Maintenance Order Example 24
Foreword
Appendix A, Appendix B, Appendix C, Appendix D and Appendix E of this standard are informative annexes.
This standard was proposed by the China Business Federation.
This standard is managed by the Ministry of Commerce of the People's Republic of China.
This standard was drafted. China Household Electrical Appliances Maintenance Association, Beijing University of Technology, Beijing Electric Engineering School, Hisense Kelon Electric Co., Ltd.
Co., Ltd., Zhuhai Gree Electric Co., Ltd.
The main drafters of this standard. Guo Chibing, Li Hongqi, Song Youshan, Liu Song, Chen Zhiqin, Wang Yunwei, Mao Guoding.
Room air conditioner disassembly and assembly
Technical specification for repair service
1 Scope
This standard specifies the disassembly/installation of the room air conditioner for household and similar purposes at the place of use and the repair service at the specified place.
Technical requirements, operational specifications and quality assessment methods.
This standard applies to the use of air-cooled condensers, fully enclosed compressors - electric motors, air conditioning in confined spaces or the same purpose
Speed controllable type and one (outdoor unit) towing more (partial indoor unit) type room air conditioner.
2 Normative references
The terms in the following documents become the terms of this standard by reference to this standard. All dated references, followed by all
Modifications (not including errata content) or revisions do not apply to this standard, however, parties to agreements based on this standard are encouraged to study
Is it possible to use the latest version of these files? For undated references, the latest edition applies to this standard.
GB 156 standard voltage
GB/T 700 carbon structure
GB 1002 Single-phase plug and socket type and basic parameters and dimensions for household and similar purposes
GB/T 3187-1994 Reliability, maintainability terminology
GB/T 3608 high work classification
Safety technical regulations for the management, use, inspection and maintenance of GB/T 3787 hand-held power tools
Safety of household and similar electrical appliances - Part 1. General requirements
GB 4706.32-2004 Safety requirements for heat pumps, air conditioners and dehumidifiers for household and similar electrical appliances
GB/T 5013 Rubber insulated cable with rated voltage of 450/750V and below
GB/T 5023 PVC insulated cable with rated voltage of 450/750V and below
GB 5306 Specialized Personnel Safety Technical Assessment Management Rules
GB/T 7373 Industrial difluorochloromethane (HCFC-22)
GB/T 7725-2004 room air conditioner
GB 8877 Safety requirements for installation, use and maintenance of household appliances
GB 9237 Safety requirements for mechanical refrigeration systems for refrigeration and heating
GB/T 12325 power quality supply voltage deviation
GB 13955 residual current action protection device installation and operation
GB 17790-1999 room air conditioner installation specification
GB 19210 Air conditioning ventilation system cleaning specification
GB 50169 Electrical installation engineering grounding device construction and acceptance specifications
AQ7004 Refrigeration and Air Conditioning Safety Technical Specifications
HG23014 Plant Area Safety Regulations
SB/T 10349-2002 Household appliance repair service department rating specification
3 Terms and definitions
The following terms and definitions apply to this standard.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of SB/T 10480-2008_English be delivered?Answer: Upon your order, we will start to translate SB/T 10480-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of SB/T 10480-2008_English with my colleagues?Answer: Yes. The purchased PDF of SB/T 10480-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|