US$209.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. MT/T 690-1997: Determination of resistance on ground and mesa conducting statial electricity in detonator production line
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| MT/T 690-1997 | English | 209 |
Add to Cart
|
3 days [Need to translate]
|
Determination of resistance on ground and mesa conducting statial electricity in detonator production line
| |
MT/T 690-1997
|
PDF similar to MT/T 690-1997
Basic data | Standard ID | MT/T 690-1997 (MT/T690-1997) | | Description (Translated English) | Determination of resistance on ground and mesa conducting statial electricity in detonator production line | | Sector / Industry | Coal Industry Standard (Recommended) | | Classification of Chinese Standard | G89 | | Classification of International Standard | 71.100.30 | | Word Count Estimation | 6,677 | | Date of Issue | 12/30/1997 | | Date of Implementation | 7/1/1998 | | Quoted Standard | GB 4385-1984; GB 12014-1989; MT 520-1995 | | Summary | This standard specifies the testing equipment and materials detonator production line static conductive floor, countertops resistance value measurement requirements and measuring step and so on. This standard applies to the production line detonator antistatic floor, countertops measured resistance value. |
MT/T 6: ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Determination of resistance on ground and mesa conducting statial electricity in detonator production line
People's Republic of China Coal Industry Standard
Detonator production line static conductive floor, table resistance value
test methods
1997-12-30 Approved.1998-07-01 Implementation
Approved by the Ministry of Coal Industry of the People's Republic of China
Contents
1 Scope 1
2 Normative references 1
3 Method summary 1
4 Instruments and materials 1
5 Test match 1
6 Determination step 2
7 Measurement object 2
8 Expression of results 2
9 Test report 2
Detonator production line static conductive floor, table resistance value
test methods
1 Scope
This standard specifies the measuring instruments and materials for the static-conductive floor and table resistance of the detonator production line, measurement requirements, and measurement procedures.
This standard is applicable to the measurement of the resistance of the static-conductive floor and table of the detonator production line.
2 Reference standards
The following standards contain provisions that, through reference in this standard, constitute provisions of this standard. When this standard was published, the editions shown were all
Is effective. All standards will be revised, and all parties using this standard should explore the possibility of using the latest versions of the following standards.
GB 4385-84 Technical requirements for anti-static shoes and conductive shoes
GB 12014-89 anti-static work clothes
MT 520-1995 Antistatic safety regulations for mine detonator production plant
3 Method summary
Connect the positive electrode of the megohmmeter to the measuring electrode, and the negative electrode to ground, and measure the resistance value between the measuring electrode and ground.
4 Instruments and materials
4.1 Instrument
500V megohmmeter. The measurement range is 1 × 102Ω ~ 1 × 1012Ω, and the accuracy is ± 5%.
4.2 Materials
a) Main electrode. chrome-plated cylindrical brass electrode. Diameter. 60mm ± 0.01mm, mass. 2kg (including handle), electrode bottom surface
Surface roughness is 1.6 μm
b) Gasket. sponge gasket. Diameter. 60mm, thickness. 5mm ~ 6mm, p = 10 ~ 102Ω · cm, hardness. 40 ~ 50 Shore.
The measurement electrodes consisting of a and b are shown in the figure.
1-Handle; 2-Main electrode; 3-Shim
Figure 1 Schematic diagram of the measuring electrode
c) Connection wire. Polyethylene sheathed multi-strand copper wire with a cross-sectional area of 1.5mm2. The insulation resistance of the wire should not be less than
5 × 108Ω.
5 Test match
5.1 Measurements must be performed after production has been stopped and products and hazardous materials have been cleaned.
5.2 During the measurement, the line connection should be safe and reliable to prevent sparks during the measurement.
5.3 If there is flammable and explosive gas dust in the room, the measurement is strictly prohibited.
5.4 When measuring, an insulation board should be placed under the instrument.
5.5 Measurement in thunderstorms is strictly prohibited.
5.6 The testing personnel shall wear antistatic work clothes in accordance with GB 12014 and antistatic shoes in accordance with GB 4385.
5.7 The measurement points for each 10m2 of the production room shall be not less than 5 points, and the measurement points for less than 10m2 or an independent piece of floor or table shall be 5 points.
Better.
6 Measurement steps
6.1 Before the measurement, if the floor is oily, it must be removed with water or neutral detergent. The floor or work surface should be dry and clean during the measurement
status.
6.2 Wet the sponge pad with water.
6.3 Choose one point on the conductive floor or work surface.
a) For non-flexible (such as FRP, etc.) conductive floor or table surface, the measurement should be placed under the main electrode wet and screwed
De-watering sponge pad.
b) For conductive floors or countertops laid with flexible (such as conductive rubber sheet, etc.), no sponge can be placed under the main electrode during measurement
Gasket.
6.4 Connect the "line" end button of the megohmmeter to the electrode, and the "ground" end button to the grounding net of the conductive ground,
The resistance value is measured, and this value is used as the resistance value to ground at the measurement point.
7 Measurement object
According to the process classification specified in Chapter 3 of MT 520, the floor and table of each process are used to measure the resistance of the measuring electrode to ground.
8 Expression of results
8.1 The data read should be retained to one digit after the decimal point.
8.2 When measuring the resistance value of several points at the same place, the highest value is the resistance value of the ground and the table within the measurement range.
9 Test report
The test report must include the following.
a) measurement time;
b) measured temperature and humidity conditions;
c) using the name and model of the instrument;
d) the location of the measurement;
e) The measured pole-to-ground resistance.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of MT/T 690-1997_English be delivered?Answer: Upon your order, we will start to translate MT/T 690-1997_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of MT/T 690-1997_English with my colleagues?Answer: Yes. The purchased PDF of MT/T 690-1997_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|