US$339.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. JJG 983-2003: Verification Regulation of Verifying Instrument for Single and Dispersion Controlled Centrally Telephone Accounter Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| JJG 983-2003 | English | 339 |
Add to Cart
|
3 days [Need to translate]
|
Verification Regulation of Verifying Instrument for Single and Dispersion Controlled Centrally Telephone Accounter
| Valid |
JJG 983-2003
|
PDF similar to JJG 983-2003
Basic data | Standard ID | JJG 983-2003 (JJG983-2003) | | Description (Translated English) | Verification Regulation of Verifying Instrument for Single and Dispersion Controlled Centrally Telephone Accounter | | Sector / Industry | Metrology & Measurement Industry Standard | | Classification of Chinese Standard | A57 | | Word Count Estimation | 13,135 | | Date of Issue | 2003-11-24 | | Date of Implementation | 2004-02-24 | | Quoted Standard | JJF 1001-1998; JJF 1059-1999; JJG 107-2002; GB/T 15279-1994; YD/T 1004-1999 | | Issuing agency(ies) | State Administration of Quality Supervision, Inspection and Quarantine | | Summary | This standard applies to a variety of stand-alone and centralized management of decentralized telephone billing Calibrator (hereinafter referred to as Calibrator) the first test, the follow-up test and in-service inspection. |
JJG 983-2003: Verification Regulation of Verifying Instrument for Single and Dispersion Controlled Centrally Telephone Accounter ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Verification Regulation of Verifying Instrument for Single and Dispersion Controlled Centrally Telephone Accounter
National Metrology Verification Regulations of the People's Republic
Released on.2003-11-24
2004-02-24 implementation
The General Administration of Quality Supervision, Inspection and Quarantine issued
Stand-alone and centralized management
Telephone meter verification instrument verification procedure
honeAccounter
This regulation was approved by the General Administration of Quality Supervision, Inspection and Quarantine on November 24,.2003, and
Implemented on February 24,.2004.
Focal Point. National Time Frequency Measurement Technical Committee
Main drafting unit. Liaoning Institute of Metrology
Participated in drafting unit. Shanghai Institute of Metrology and Testing Technology
Hunan Institute of Metrology and Testing Technology
Hangzhou Jinshuo Technology Development Co., Ltd.
This procedure entrusts the National Time Frequency Measurement Technical Committee to explain
The main drafters of this procedure.
Sun Jialin (Liaoning Institute of Metrology)
Yan Xiaoju (Liaoning Institute of Metrology)
Participate in the drafters.
Zhu Genfu (Shanghai Institute of Metrology and Testing Technology)
Peng Zhengliang (Hunan Institute of Metrology and Testing Technology)
Sun Yinhai (Hangzhou Jinshuo Technology Development Co., Ltd.)
table of Contents
1 Scope (1)
2 Citations (1)
3 Overview (1)
4 Metrology performance requirements (1)
4.1 Internal Crystal Frequency Accuracy A (1)
4.2 Output time interval T (1)
4.3 issue characteristics (1)
4.4 Storage Rate and Billing Amount (1)
4.5 Output Feed Voltage, Current and Maximum Allowable Error (1)
4.6 Electrical Characteristics (1)
5 General technical requirements (2)
5.1 Appearance and logo (2)
5.2 Function (2)
6 measuring instrument control (2)
6.1 Verification conditions (2)
6.2 Verification equipment (2)
6.3 Verification project (2)
6.4 Verification method (2)
6.5 Processing of verification results (4)
6.6 Verification cycle (4)
Appendix A Technical Requirements for Numbering (5)
Appendix B Verification method of electrical performance indicators (6)
Appendix C Verification Certificate (inside page) format (7)
Stand-alone and centralized management
Telephone meter verification instrument verification procedure
1 Scope
This procedure is applicable to all kinds of single-type and centralized management decentralized telephone meter verification instruments (hereinafter referred to as the verification instrument)
First verification, follow-up verification and in-use inspection.
2 Citations
This procedure refers to the following documents.
JJF1001-1998 General Terms and Definitions
JJF1059-1999 "Measurement and Expression of Measurement Uncertainty"
JJG 107-2002 "Single-type and centralized management of decentralized billing telephone timing meter" verification procedures
GB/T 15279-1994 "Automatic telephone technical conditions"
YD/T 1004-1999 "Technical requirements and test methods for multi-channel telephone billing system"
When using this procedure, care should be taken to use the current valid version of the above cited documents.
3 Overview
The calibration instrument is used for verification of single-type and centralized management of distributed billing type telephone timing meter (hereinafter referred to as billing)
Special instrument for the device). The internal design of the analog program-controlled switching circuit, using the microprocessor for timing and control, can
The standard billing signal is outputted, and the verification of the meter is completed by comparing with the meter.
4 Metrological performance requirements
4.1 Internal crystal frequency accuracy A. 5 × 10-5.
4.2 Output time interval T. Range. 0.1s~1200s,
Step interval. 0.1s,
Maximum allowable error. ± (T × A 0.1) s.
4.3 Issue characteristics. See Appendix A.
4.4 Storage Rate and Billing Amount
The storage rate and billing amount of the verifier should be exactly the same as those of the local price department or the competent department of the industry.
4.5 Output feed voltage, current and maximum allowable error
The feed voltage is 48V and the maximum allowable error is ±1V;
Feed current range. 10mA~40mA, the maximum allowable error is ±1mA.
4.6 Electrical characteristics
4.6.1 Maximum allowable error of intervention attenuation. ±0.1dB.
4.6.2 Maximum allowable error of frequency response. ±0.1dB.
4.6.3 Maximum allowable error of insulation resistance. ±10%.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJG 983-2003_English be delivered?Answer: Upon your order, we will start to translate JJG 983-2003_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJG 983-2003_English with my colleagues?Answer: Yes. The purchased PDF of JJG 983-2003_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|