|
US$419.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. JJG 841-2012: Verification Regulation of Microwave Frequency Counters Status: Valid JJG 841: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| JJG 841-2012 | English | 419 |
Add to Cart
|
3 days [Need to translate]
|
Verification Regulation of Microwave Frequency Counters
| Valid |
JJG 841-2012
|
| JJG 841-1993 | English | 239 |
Add to Cart
|
2 days [Need to translate]
|
Verification Regulation of Microwave Frequency Couters
| Obsolete |
JJG 841-1993
|
PDF similar to JJG 841-2012
Basic data | Standard ID | JJG 841-2012 (JJG841-2012) | | Description (Translated English) | Verification Regulation of Microwave Frequency Counters | | Sector / Industry | Metrology & Measurement Industry Standard | | Classification of Chinese Standard | A57 | | Classification of International Standard | 17.080 | | Word Count Estimation | 18,126 | | Older Standard (superseded by this standard) | JJG 841-1993 | | Quoted Standard | JJG 180-2002 | | Regulation (derived from) | AQSIQ Announcement No. 45 of 2012 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | | Summary | This standard applies to the frequency range of 100kHz ~ 40GHz microwave frequency counters and other instruments in the microwave frequency counter function module initial verification, testing and use of follow-up checks. |
JJG 841-2012: Verification Regulation of Microwave Frequency Counters---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Verification Regulation of Microwave Frequency Counters
State verification procedures People's Republic of China
Microwave frequency counter
Issued on. 2012-03-20
2012-09-20 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
Microwave frequency counter test procedures
Counters
Replacing JJG 841-1993
Focal point. the National Commission on Time and Frequency Measurement Technology
Main drafting unit. Shanghai Institute of Measurement and Testing
China Testing Technology Research Institute
Participated in the drafting. Instrument Co., Ltd. Nanjing Telecommunications Union
The national time and frequency measurement procedures commissioned technical committee responsible for the interpretation
The main drafters of this procedure.
Dong Lin (Shanghai Institute of Measurement and Testing)
Guo Chunmei (China Testing Technology Research Institute)
Drafters participate.
Chen Yajun (Nanjing Telecommunications Union Instrument Co., Ltd.)
Liu Qihua (Shanghai Institute of Measurement and Testing)
Hu Lizhi (Shanghai Institute of Measurement and Testing)
table of Contents
Introduction (Ⅱ)
1 Scope (1)
2. References (1)
3 Terms (1)
3.1 Input sensitivity (1)
3.2 Maximum Input Level (1)
4 Overview (1)
5 metering performance requirements (1)
5.1 Input characteristics (1)
5.2 Frequency measurement error (2)
5.3 Built-in quartz crystal oscillator (2)
6 General Requirements (2)
6.1 Appearance (2)
6.2 of the work (2)
7 control of measuring instruments (2)
7.1 verification Conditions (2)
7.2 test items and test methods (3)
7.3 Verification Results Processing (6)
7.4 test cycle (6)
Appendix A test page original record data format (7)
B test certificates/test results in the notice page format Shape Appendix (9)
Introduction
JJG 841 "microwave frequency counter" is the revised version of JJG 841-1993 conducted. And JJG 841-1993
Compared to, in addition to editorial changes outside the main technical changes are as follows.
--- Increase the frequency measurement limit (see Chapter 1);
--- New introduction, the term content (see Introduction and Chapter 3);
--- Complement the performance requirements for content measurement (see Chapter 5);
--- Refine and clarify the test conditions (see 7.1);
--- Provisions of the applicable conditions of different test methods, eliminating synthetic, frequency converters, modular signal attenuator
Generating method and splitters method (see 7.2.2.3);
--- New frequency measurement error test items and test methods (see 5.2 and 7.2.2.4);
--- Test new original record data page format (see Appendix A), calibration certificate/test results within the page frame notice
Type style (see Appendix B).
JJG 841-1993 for the first release.
Microwave frequency counter test procedures
1 Scope
The order applies to the measurement frequency range of 100kHz ~ 40GHz microwave frequency counter and other instruments
The microwave frequency counting function module initial verification, use and subsequent verification check.
2. References
JJG 180-2002 "electronic measuring instruments within the quartz oscillator"
For dated references, only the dated edition applies to this procedure; undated reference documents
Member, the latest edition (including any amendments) applies to this procedure.
3 Terms
3.1 Input sensitivity inputsensitivity
Microwave frequency counter works fine and the reading is stable, the measured signal is accurate minimum required level value.
3.2 Maximum input level maximuminputlevel
Microwave frequency counter works fine and the reading is stable, the measured signal is accurate can withstand the maximum level value.
4 Overview
Microwave frequency counter frequency measurement refers to the upper reaches of the microwave frequency counter, also known as the microwave frequency counter. it
Usually down-conversion technology, microprocessor controlled by the frequency of the measured microwave signals can be converted into a counter
Direct measurement of the frequency, widely used in national defense, scientific research, universities and military departments measuring microwave, millimeter wave band power
Signal frequency.
5 metering performance requirements
5.1 Input characteristics
Input characteristics are shown in Table 1.
Table 1 Input characteristics
Technical Specifications
Bands
Frequency range 100kHz ~ 1GHz (1 ~ 18) GHz (18 ~ 26.5) GHz (26.5 ~ 40) GHz
Input sensitivity (20 ~ 300) mV (-33 ~ -20) dBm (-29 ~ -17) dBm (-23 ~ -15) dBm
The maximum input level (2 ~ 7) V (5 ~ 13) dBm (7 ~ 13) dBm (7 ~ 13) dBm
BNC input connector type N-type socket/SMA and other 3.5mm/K type, etc. 2.4mm/K type, etc.
Note. The band division and technical specifications to the product specification shall prevail.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJG 841-2012_English be delivered?Answer: Upon your order, we will start to translate JJG 841-2012_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJG 841-2012_English with my colleagues?Answer: Yes. The purchased PDF of JJG 841-2012_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version JJG 841-2012?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 841-2012 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|