US$529.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. JJG 773-2013: Verification Regulation of Medical Radiation Source for γ-ray Afterloading Brachytherapy Status: Valid JJG 773: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJG 773-2013 | English | 529 |
Add to Cart
|
4 days [Need to translate]
|
Verification Regulation of Medical Radiation Source for γ-ray Afterloading Brachytherapy
| Valid |
JJG 773-2013
|
JJG 773-1992 | English | 279 |
Add to Cart
|
3 days [Need to translate]
|
Verification Regulation of After Loading γ-Radiation Source for Brachytherapy
| Obsolete |
JJG 773-1992
|
PDF similar to JJG 773-2013
Basic data Standard ID | JJG 773-2013 (JJG773-2013) | Description (Translated English) | Verification Regulation of Medical Radiation Source for ��-ray Afterloading Brachytherapy | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A58 | Classification of International Standard | 17.240 | Word Count Estimation | 23,265 | Older Standard (superseded by this standard) | JJG 773-1992 | Quoted Standard | JJF 1035; GB 4075; GB 9706.13-2008; GBZ 121-2002 | Regulation (derived from) | ?State AQSIQ Announcement 2013 No. 28 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This standard applies to medical ��-ray after-loading brachytherapy radiation (dose rate range of about 0. 01 Gy/min ~ 5 Gy/min) the initial verification, follow-up test and use checks. This procedure does not apply to the medical neutron brachytherapy rad |
JJG 773-2013: Verification Regulation of Medical Radiation Source for γ-ray Afterloading Brachytherapy ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Verification Regulation of Medical Radiation Source for γ-ray Afterloading Brachytherapy
State verification procedures People's Republic of China
After the medical device γ-ray radiation brachytherapy
Issued on. 2013-02-16
2013-08-16 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
After the medical device γ-ray brachytherapy
Radiation test procedures
py
Alternative JJG 773-1992
Focal point. the National Technical Committee of ionizing radiation metrology
Main drafting unit. Shenzhen Academy of Metrology and Quality Inspection
Zhejiang Institute of Metrology
Henan Institute of Metrology
Participated in the drafting unit. Hubei Provincial People's Hospital
Beijing Institute of Metrology detection
This procedure commissioned the National Technical Committee is responsible for ionizing radiation measurement interpretation
The main drafters of this procedure.
Zhou Yingchun (Shenzhen Academy of Metrology and Quality Inspection)
Mao Dingli (Zhejiang Institute of Metrology)
Lee name trillion (Shenzhen Academy of Metrology and Quality Inspection)
Ma Long (Henan Institute of Metrology)
Drafters participate.
Xu Liming (Hubei Provincial People's Hospital)
Xu Tao (Shenzhen Academy of Metrology and Quality Inspection)
Ask Lu (Beijing Institute of Metrology detection)
table of Contents
Introduction (Ⅱ)
1 Scope (1)
2. References (1)
3 terminology and units of measurement (1)
3.1 The term (1)
3.2 units of measurement (2)
4 Overview (2)
5 metering performance requirements (2)
5.1 dose repeatability (2)
5.2 dose error (2)
5.3 source equivalent activity (2)
5.4 radiation directivity (2)
5.5 Transfer position deviation source (2)
6 General technical conditions (3)
6.1 Equipment Signs (3)
6.2 Display (3)
7 control of measuring instruments (3)
7.1 test conditions (3)
7.2 Verification Project (4)
7.3 Verification Methods (4)
7.4 Verification Results Processing (7)
7.5 test cycle (7)
Appendix A of the ionization chamber line correction factor (8)
Appendix B and the water absorbed dose conversion factor Cλx and exposure to air kerma conversion factor Cλk (9)
Appendix C after brachytherapy commonly used radionuclides exposure rate constant τx and air kerma rate constant τk (10)
Appendix D aqueous medium attenuation and scatter correction factor S (r) (11)
Appendix E water phantom measuring bracket (12)
Appendix F Medical γ rays after loading brachytherapy radiation test recording format pattern (13)
Appendix G calibration certificate/test results in the notice page format pattern (15)
Introduction
This procedure based on JJF1002-2010 "national verification procedures to write the rules" to prepare.
The regulations replace JJG 773-1992 "close after γ-ray radiation brachytherapy."
This procedure compared with JJG 773-1992, in addition to editorial changes, the main technical differences are as follows.
--- According to the requirements JJF1002-2010, an increase of introduction;
--- Increasing the ionization chamber line of the amended definition (see 3.1.5); and in absorbed dose calculation formula, modify agent
The amount of the gradient correction factor for the ionization chamber line of the correction factor (see 7.3.2.1 and Appendix A);
After loading dose radiation output --- modified randomly selected multiple sources (radiation) source system repeatability to
Seek, from 5% modified to not more than 3.0% (see 5.1.2);
--- Increase the radiation directivity requirements and test methods (see 5.4 and 7.3.4);
--- Modify the phantom and measurement bracket requirements (see 7.1.2.2);
--- Increasing the absorbed dose to the applicator error assays and kinds of provisions "when the test is administered must
Comprising at least one metal hose applicator and applicator "(see 7.3.2.5);
Test methods --- transmission source of bias in place, for photographic film with a slow method of modifying the original procedures described
Said that verification operational, while the image size by specifying sources formed to standardize imaging quality
Volume, thereby improving the accuracy of measurement (see 7.3.5.1);
--- Increasing the typical radionuclide air kerma conversion factor Cλk value queries (see Appendix B).
The previous versions of the release JJG 773 case.
--- JJG 773-1992.
After the medical device γ-ray brachytherapy
Radiation test procedures
1 Scope
The order applies to medical γ-ray after-loading brachytherapy radiation (dose rate range of about 0.01Gy/min ~
5Gy/min) the initial verification, use and subsequent verification check.
This procedure does not apply to medical neutron radiation sources close brachytherapy, radiation therapy and medical Sticking seed implantation
Radiation therapy and other verification.
2. References
This procedure references the following documents.
JJF1035 ionizing radiation measurement terms and definitions
GB 4075 Sealed radioactive sources - General requirements and classification
GB 9706.13-2008 Medical electrical equipment - Part 2. automatic control of brachytherapy equipment installed
Requirements for safety (IEC 60601-2-17.2004, IDT)
GB Z121-2002 after loading brachytherapy source γ health protection standard
For dated references, only the dated edition applies to this procedure; undated reference documents
Member, the latest edition (including any amendments) applies to this procedure.
3 terminology and units of measurement
JJF1035 "ionizing radiation measurement terminology and definitions" and defined the following terms and definitions apply to this procedure.
3.1 Terms
3.1.1 After installation technology afterloadingtechniques
Pre-positioned in a patient in need of treatment administered the site correctly, then the inner receptacle radioactive source is input applicator
In the implementation of treatment technologies.
3.1.2 γ-rays after loading brachytherapy γ-rayafterloadingbrachytherapy
With mounting technology, in accordance with the clinical requirements, so that γ radioactive source resides or shipped between the body's natural cavity, duct or tissue
Moving, but to achieve a predetermined dose of radiation treatment and distribution.
3.1.3 applicator radiationsourcesapplicator
Previously placed between the body cavity, duct or tissue, for presence or movement of radioactive sources, and the implementation of a special container treatment
Treatment is also known. Such as a needle, tube, or have other special shape of the applicator.
3.1.4 source storage device storecontainerofradiationsources
After the storage container brachytherapy radioactive sources.
3.1.5 ionization chamber line corrections correctionofionizationchamberdimension
In the dose distribution, since the distance between the point source is too close, the ionization chamber can not be seen as a correction point detectors carried out, such a
Fixed distance main ionization chamber cavity with maximum size and point source related to the ionization chamber.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJG 773-2013_English be delivered?Answer: Upon your order, we will start to translate JJG 773-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJG 773-2013_English with my colleagues?Answer: Yes. The purchased PDF of JJG 773-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version JJG 773-2013?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 773-2013 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|