US$329.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. JJG 478-2016: α, β Surface Contamination Monitors Status: Valid JJG 478: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJG 478-2016 | English | 329 |
Add to Cart
|
3 days [Need to translate]
|
α, β Surface Contamination Monitors
| Valid |
JJG 478-2016
|
JJG 478-1996 | English | 279 |
Add to Cart
|
3 days [Need to translate]
|
V.R.of Alpha Beta and Gamma Surface Contamination Instruments
| Obsolete |
JJG 478-1996
|
JJG 478-1986 | English | RFQ |
ASK
|
3 days [Need to translate]
|
(Chinese Industry Standard)
| Obsolete |
JJG 478-1986
|
PDF similar to JJG 478-2016
Basic data Standard ID | JJG 478-2016 (JJG478-2016) | Description (Translated English) | ��, �� Surface Contamination Monitors | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A58 | Word Count Estimation | 14,184 | Date of Issue | 2016-11-30 | Date of Implementation | 2017-05-30 | Older Standard (superseded by this standard) | JJG 478-1996 | Quoted Standard | JJF 1001-2011; GB/T 4960.1-2010; GB/T 4960.6-2008; GB/T 5202-2008; GB/T 8997-2008 | Regulation (derived from) | State Administration of Quality Supervision, Inspection and Quarantine Notice No.119 of 2016 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This standard applies to the first test of ��, �� surface contamination test, follow-up inspection and inspection in use, including �� surface contamination measuring instrument and monitor, �� surface contamination measuring instrument and monitor, and ��/�� surface contamination measuring instrument and monitoring instrument. This procedure does not apply to the fixed ��, �� personal surface contamination measurement monitoring device and the maximum energy less than 60 keV �� particle measurement or monitoring instrument verification. |
JJG 478-2016: α, β Surface Contamination Monitors---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
α, β Surface Contamination Monitors
National Metrological Verification Regulation of the People's Republic of China
α, β surface contamination meter
2016-11-30 release
2017-05-30 implementation
State Administration of Quality Supervision, Inspection and Quarantine issued
Verification procedure of α, β surface contamination meter
VerificationRegulationforα, β
Replacing JJG 478-1996
Unit. National Diameter Radiation Metrology Technical Committee
The main drafting unit. Shanghai Institute of Metrology and Testing Technology
Participated in the drafting unit. Beijing Institute of Metrology and Testing
Shenzhen Institute of Measurement and Quality Inspection
This procedure is entrusted to the National Council on Ionizing Radiation Metrology
The main drafters of this procedure.
Tang Fangdong (Shanghai Institute of Metrology and Testing Technology)
He Linfeng (Shanghai Institute of Metrology and Testing Technology)
ZHAO Gui-kun (Beijing Institute of Metrology and Measurement Science)
Zhou Yingchun (Shenzhen Institute of Measurement and Quality Inspection)
Participate in the drafters.
Luo Chen (Beijing Institute of Metrology and Testing)
Li Mingzhao (Shenzhen Institute of Measurement and Quality Inspection)
Lu Xiaojun (Shanghai Institute of Metrology and Testing Technology)
table of Contents
Introduction (II)
1 Scope (1)
2 References (1)
3 terms and units of measurement (1)
3.1 Terms (1)
3.2 Unit of measurement (1)
4 Overview (1)
5 Measurement performance requirements (2)
6 General technical requirements (2)
6.1 Appearance (2)
6.2 Identification (2)
7 Metering device control (2)
7.1 Test conditions (2)
7.2 Verification Project (3)
7.3 Verification method (3)
7.4 Processing of test result (4)
7.5 Test cycle (4)
Appendix A Test Record Recommended Format (5)
Appendix B Certification Certificate Information and Recommended Formats (6)
Appendix C Results of the results of the notice and recommended format (7)
Appendix D Surface activity response and its calculation method (8)
Appendix E Methods of measurement of calibration factors (9)
Introduction
α, β surface contamination meter is a commonly used radiation protection equipment for open radioactive workplace radioactive surface
Pollution monitoring, the measurement performance directly affect the monitoring results of accurate and reliable, related to radiation safety.
JJF1002-2010 "Rules for the preparation of national metrological verification procedures", JJF1001-2011 "General measurement terms and
Definition ", JJF1059.1-2012" measurement uncertainty assessment and representation "together constitute the basis for the development of the rules
Nature specification. The revision of this procedure is based on GB/T 8997-2008 "α, β surface contamination measuring instrument and monitor
Quasi ", GB/T 5202-2008" radiation protection equipment α, β and α/β (β energy greater than 60keV) pollution measuring instrument and
Monitor "as the main technical reference.
Compared with JJG 478-1996, in addition to editorial changes, the main technical changes are as follows.
--- the name of the program changed to "α, β surface pollution meter", canceled the "γ surface pollution meter";
- Increased requirements for standard plane source value uncertainty;
--- to relax the test conditions on the ambient temperature requirements;
--- cancel the "β energy response" test items;
--- increase the "background count rate" test items;
--- "surface emissivity response" instead of "surface activity response";
--- "basic error" is replaced by "relative inherent error";
The method of calculating the surface activity response and the measurement method of the calibration factor in the appendix.
The previous versions of this order are released as follows.
--- JJG 478-1996.
Verification procedure of α, β surface contamination meter
1 Scope
This procedure applies to the first test of α, β surface contamination meter, subsequent verification and inspection in use, including α surface
Pollution measuring instrument and monitor, β surface contamination measuring instrument and monitor, and α/β surface contamination measuring instrument and monitor.
This procedure does not apply to fixed α, β personal surface contamination measurement monitoring devices and the maximum energy less than 60keV
Of the beta particle measurement or monitoring instrument.
2 reference file
This procedure refers to the following documents.
Standard Terminology and Definitions for JJF1001-2011
Nuclear science and technology terminology - Part 1. Nuclear physics and nuclear chemistry GB/T 4960.1-2010
Nuclear science and technology terminology - Part 6. Nuclear instrumentation GB/T 4960.6-2008
GB/T 5202-2008 Radiation protection equipment α, β and α/β (β energy greater than 60keV) Pollution measuring instrument and
Monitor
GB/T 8997-2008 Calibration of α, β surface contamination measuring instrument and monitor
For dated references, only the dated edition applies to this rule; references that are not dated
, The latest version (including all modified units) applies to this procedure.
3 terms and units of measurement
3.1 terminology
JJF1001-2011, GB/T 4960.1-2010, GB/T 4960.6-2008 Defined and the following terms and
The definition applies to this procedure.
3.1.1 Surface emissivity response surfaceemissionrateresponse
Under certain conditions, the response of the measuring instrument or device (system) to the stimulating effect is called a response
The indication of the value and the amount of encouragement. When the magnitude of the radiation source is expressed as the surface emissivity, it is called the surface emissivity
response.
3.1.2 Surface activity response surfaceactivityresponse
α, β surface contamination of the standard plane source of the value of the standard plane with the unit area of the activity of the quotient.
3.2 Units of measurement
3.2.1 [radioactive] activity. beige [lux]; symbol. Bq.
3.2.2 [source] Surface emissivity. 2π particles per minute; Symbol. (min · 2πsr) -1.
4 Overview
α, β surface contamination meter includes portable α, β surface contamination measuring instrument and monitor, which has the alarm function.
By the detector, signal processing and display components, usually using scintillator detectors or gas detectors for the opening
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJG 478-2016_English be delivered?Answer: Upon your order, we will start to translate JJG 478-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJG 478-2016_English with my colleagues?Answer: Yes. The purchased PDF of JJG 478-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version JJG 478-2016?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 478-2016 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|