US$459.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. JJG 393-2018: Portable Ambient Dose Equivalent (Rate) Meters and Monitors for X and gamma Radiations Status: Valid JJG 393: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJG 393-2018 | English | 459 |
Add to Cart
|
4 days [Need to translate]
|
Portable Ambient Dose Equivalent (Rate) Meters and Monitors for X and gamma Radiations
| Valid |
JJG 393-2018
|
JJG 393-2003 | English | 839 |
Add to Cart
|
5 days [Need to translate]
|
Verification Regulation of X and Gamma Radiation Dose Equivalent (Rate) Meters and Monitors Used in Radiation Protection
| Obsolete |
JJG 393-2003
|
JJG 393-1985 | English | 639 |
Add to Cart
|
5 days [Need to translate]
|
Verification Regulation of γRadiation Protection Instruments
| Obsolete |
JJG 393-1985
|
PDF similar to JJG 393-2018
Basic data Standard ID | JJG 393-2018 (JJG393-2018) | Description (Translated English) | Portable Ambient Dose Equivalent (Rate) Meters and Monitors for X and gamma Radiations | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A58 | Classification of International Standard | 17.240 | Word Count Estimation | 20,225 | Date of Issue | 2018-12-25 | Date of Implementation | 2019-06-25 | Older Standard (superseded by this standard) | JJG 393-2003 | Quoted Standard | JJF 1001; JJF 1035; GB/T 4835.1-2012; GB/T 4960.1; GB/T 4960.6; GB/T 12162.1; GB/T 12162.2; GB/T 12162.3; ICRU REPORT 47-1992 | Regulation (derived from) | Natural Resources Department Announcement No. 7 of 2019 | Issuing agency(ies) | State Administration for Market Regulation | Summary | This standard applies to the first verification, follow-up verification and in-use inspection of the portable X and �� radiation surrounding dose equivalent (rate) instrument and monitor. The surrounding dose equivalent H (10) and the dose equivalent rate H (10) are generated by externally irradiated X and �� radiation, and the X, �� radiant energy ranges from 80 keV to 1.5 MeV. This standard does not apply to the verification of passive measuring devices such as film dosimeters, thermoluminescent dosimeters or quartz wire electrometers. |
JJG 393-2018: Portable Ambient Dose Equivalent (Rate) Meters and Monitors for X and gamma Radiations ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Portable Ambient Dose Equivalent (Rate) Meters and Monitors for X and gamma Radiations
National Metrology Verification Regulations of the People's Republic
Portable X, γ radiation surrounding dose
Equivalent (rate) meter and monitor
Published on.2018-12-25
2019-06-25 implementation
State Market Supervisory Administration released
Portable X, gamma radiation surrounding dose equivalent
(rate) instrument and monitor verification procedures
XandγRadiations
Replace JJG 393-2003
Focal Point. National Ionizing Radiation Measurement Technical Committee
Drafting unit. Shanghai Institute of Metrology and Testing Technology
China Institute of Metrology
This regulation entrusts the National Ionizing Radiation Measurement Technical Committee to explain
Drafters of this procedure.
Chen Jianxin (Shanghai Institute of Metrology and Testing Technology)
Li Dehong (China Institute of Metrology)
Tang Fangdong (Shanghai Institute of Metrology and Testing Technology)
Bai Xue (Shanghai Institute of Metrology and Testing Technology)
table of Contents
Introduction (II)
1 Scope (1)
2 References (1)
3 Terms and units of measurement (1)
3.1 Terminology (1)
3.2 Unit of measurement (2)
4 Overview (2)
5 Metrological performance requirements (2)
6 General technical requirements (3)
6.1 Appearance (3)
6.2 Identification (3)
6.3 Functional characteristics (3)
7 measuring instrument control (3)
7.1 Verification conditions (3)
7.2 Verification project (5)
7.3 Verification method (5)
7.4 Processing of verification results (7)
7.5 Verification cycle (7)
Appendix A Recommended Recording Format (8)
Appendix B Recommended Format for Certification Certificate (9)
Appendix C Recommended Format of the Test Result Notice (10)
Appendix D Reference Radiation Characteristics and Related Conversion Coefficients (11)
Appendix E Statistical Fluctuations (12)
Appendix F Measurement and Expression of Energy/Impact Angle Response (15)
Introduction
JJF1002-2010 "Rules for the preparation of national metrological verification procedures", JJF1001-2011 "General measurement terminology and
Definitions, JJF1059.1-2012 "Measurement Uncertainty Evaluation and Representation" together constitute the basis for the development of this regulation
Basic norms.
This procedure is for JJG 393-2003 "X, γ radiation dose equivalent (rate) instrument and monitor for radiation protection"
Amendment to GB/T 4835.1-2012 "radiation protection equipment beta, X and gamma radiation around and/or directed dose when
Measurements and/or monitors Part 1. Portable workplaces and environmental measuring instruments and monitors,
GB/T 12162.1 "X and γ reference radiation for calibrating dosimeters and dose rate meters and determining their energy response
Part 1. Radiation characteristics and production methods, GB/T 12162.2 "for calibration of dosimeters and dose rate meters and indeed
X and γ reference radiation for its energy response Part 2. 8keV~1.3MeV and 4MeV~9MeV
Dose determination of radiation, GB/T 12162.3 "for calibrating dosimeters and dose rate meters and determining their energy response
X and γ reference radiation Part 3. Calibration of site dosimeters and surrounding dosimeters and their energy response and angular response
The determination should be the main technical reference.
The main technical changes in this revision are as follows.
1. Refer to GB/T 4835.1-2012, the name is "radiation protection X, gamma radiation dose equivalent (rate) meter and
The monitor was revised to "portable X, gamma radiation surrounding dose equivalent (rate) instrument and monitor".
2. In the verification project, cancel the “overload characteristic” “alarm threshold error” and change the “energy/incident angle response” to “can”
Volume response".
3. Refer to the measurement performance requirements and verification methods for the "relative inherent error, repeatability, energy response" project.
The technical requirements and test methods of GB/T 4835.1-2012 are modified accordingly.
4. Add “Energy/incident angle response measurement method and calibration factor” in the appendix.
The previous release of this procedure.
---JJG 393-2003;
---JJG 393-1985 and JJG 483-1986.
Portable X, γ radiation surrounding dose
Equivalent (rate) instrument and monitor verification procedures
1 Scope
This procedure is applicable to the first verification and follow-up of the dose equivalent (rate) meter and monitor around portable X and γ radiation.
Verification and in-use inspection. Peripheral dose equivalent H*(10) and dose equivalent rate H
*(10) X, γ radiation from external illumination
The X, γ radiant energy ranges from 80 keV to 1.5 MeV.
This procedure does not apply to passive measuring devices such as film dosimeters, thermoluminescent dosimeters or quartz wire electrometers.
Verification.
2 reference files
This procedure refers to the following documents.
JJF1001 General Measurement Terms and Definitions
JJF1035 Terms and definitions of ionizing radiation measurement
GB/T 4835.1-2012 Radiation protection equipment β, X and γ radiation around and/or directed dose equivalent (rate)
Instruments and/or monitors - Part 1. Portable workplaces and environmental measuring devices and monitors
GB/T 4960.1 Technical terminology of nuclear science - Part 1. Nuclear physics and chemistry
GB/T 4960.6 Nuclear science and technical terms - Part 6. Nuclear instrumentation
GB/T 12162.1 X and γ reference for calibrating dosimeters and dose rate meters and determining their energy response
Radiation Part 1. Radiation characteristics and methods of production
GB/T 12162.2 X and γ reference for calibrating dosimeters and dose rate meters and determining their energy response
Radiation Part 2. Dosimetry of reference radiation from 8 keV to 1.3 MeV and 4 MeV to 9 MeV
GB/T 12162.3 X and γ reference for calibrating dosimeters and dose rate meters and determining their energy response
Radiation Part 3. Calibration of site dosimeters and surrounding dosimeters and determination of their energy and angular response
ICRUReport47.1992 Measurement of externally illuminated photons and electron radiation dose equivalents (Measurementof
Doseequivalentfromexternalphotonandelectronradiations)
For dated references, only dated versions apply to this Code; any undated references
The latest version of the document (including all amendments) applies to this procedure.
3 terms and units of measure
3.1 Terms
JJF1001, JJF1035, GB/T 4960.1, GB/T 4960.6 define the following terms and definitions apply
In this procedure.
3.1.1 surrounding dose equivalent ambientdoseequivalentH *(10)
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJG 393-2018_English be delivered?Answer: Upon your order, we will start to translate JJG 393-2018_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJG 393-2018_English with my colleagues?Answer: Yes. The purchased PDF of JJG 393-2018_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version JJG 393-2018?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 393-2018 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|