US$279.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. JJG 2037-2015: Verification Scheme of Measuring Instruments for Air-borne Sound Pressure Status: Valid JJG 2037: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJG 2037-2015 | English | 279 |
Add to Cart
|
3 days [Need to translate]
|
Verification Scheme of Measuring Instruments for Air-borne Sound Pressure
| Valid |
JJG 2037-2015
|
JJG 2037-2004 | English | 399 |
Add to Cart
|
3 days [Need to translate]
|
Verification Scheme of Measuring Instruments for Air Borne Acoustics Pressure
| Obsolete |
JJG 2037-2004
|
JJG 2037-1989 | English | 239 |
Add to Cart
|
2 days [Need to translate]
|
Verification Scheme of Measuring Instruments for Air Acoustics Pressure
| Obsolete |
JJG 2037-1989
|
PDF similar to JJG 2037-2015
Basic data Standard ID | JJG 2037-2015 (JJG2037-2015) | Description (Translated English) | Verification Scheme of Measuring Instruments for Air-borne Sound Pressure | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A59 | Classification of International Standard | 17.140 | Word Count Estimation | 12,192 | Date of Issue | 2015-02-09 | Date of Implementation | 2015-08-09 | Older Standard (superseded by this standard) | JJG 2037-2004 | Regulation (derived from) | State Quality Inspection Administration Announcement 2015 No. 26 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This Standard applies to the money transfer air sound pressure measuring instruments. It provides air sound through the air pressure measurement reference sound pressure measurement standard to the money transfer program of work for the appliance between the value transfer method and measurement uncertainty. In carrying out the calibration can also be used as a basis for traceability. |
JJG 2037-2015: Verification Scheme of Measuring Instruments for Air-borne Sound Pressure---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Verification Scheme of Measuring Instruments for Air-borne Sound Pressure
People's Republic of China National Metrological Verification System tables
Air sound pressure measuring instruments
Issued on. 2015-02-09
2015-08-09 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
Air sound pressure measuring instruments
Verification System
Replacing JJG 2037-2004
Focal point. the National Committee of the acoustic measurement technology
Drafting units. China Institute of Metrology
China Testing Technology Research Institute
Shenzhen Academy of Metrology and Quality Inspection
The Verification System commissioned the National Technical Committee Acoustic responsible for the interpretation of measurement
The Verification System drafters.
He Longbiao (China Institute of Metrology)
Niu Feng (China Institute of Metrology)
E treatment group (China Testing Technology Research Institute)
Xu Huan (China Institute of Metrology)
Pu Zhiqiang (China Testing Technology Research Institute)
Hao Yu-chuan (China Testing Technology Research Institute)
Zhang Guoqing (Shenzhen Academy of Metrology and Quality Inspection)
table of Contents
Introduction (Ⅱ)
1 Scope (1)
2 air sound pressure measurement reference (1)
2.1 Overview (1)
2.2 coupling cavity reciprocity method of sound pressure reference means (1)
2.3 free field reciprocity method of sound pressure reference means (2)
2.4 coupling cavity reciprocity method of sound pressure secondary standard device (2)
3 air sound pressure measurement standards (3)
3.1 Overview (3)
3.2 working standard microphone calibration device (3)
3.3 acoustic calibrator verification device (4)
3.4 Sound Level Meter calibration device (4)
3.5 standard sound source verification device (4)
3.6 Calibration acoustic sensor means (4)
4 air sound pressure measuring instruments work (4)
4.1 Overview (4)
4.2 working standard microphones (4)
4.3 sound calibrators (4)
4.4 Sound Level Meter (5)
4.5 standard sound source (5)
4.6 Sound intensity meter (5)
4.7 Sound meter (5)
4.8 ultrasonic measuring instrument (5)
5 air sound pressure measuring instruments Verification System block diagram (5)
Introduction
The Verification System based JJF1104-2003 "National Metrological Verification System write rules" in preparation.
The verification system in place JJG 2037-2004 "sound of air pressure measuring instruments." And JJG 2037-2004 phase
Ratio, the main technical changes are as follows.
--- Coupled cavity reciprocity method reference sound pressure by the lower limit of the frequency range of 20Hz extended to 2Hz;
--- Upper frequency limit range free-field sound pressure from baseline extended to 20kHz 50kHz;
--- The original electro-acoustic refinement of standard equipment for the working standard microphone calibration device, acoustic calibrator verification device,
Sound level meter verification device, standard sound source verification device, infrasound sensor calibration devices, including infrasound sensor calibration device
Home is new.
The previous version of the verification system for the release of the case.
--- JJG 2037-1989;
--- JJG 2037-2004.
Air sound pressure measuring instruments Verification System
1 Scope
The verification system applicable to money transfer sound of air pressure measuring instruments. It provides air sound pressure metering group
Associate sound through the air pressure measurement standards to working measuring instruments of value transfer procedure between the value transfer method and measurement are not
Degree of certainty. In carrying out the calibration can also be used as a basis for traceability.
2 air reference sound pressure measurement
2.1 Overview
Air pressure measurement reference for sound reproduction and preservation of sound pressure values of air units, and measurement standards through the work of
Measuring instruments of value transfer. The unit of sound pressure values Pa, SPL value in units of dB, reference sound pressure
20μPa.
Air reference sound pressure measurement means coupled cavity reciprocity method of sound pressure reference means, coupled cavity reciprocity law Deputy reference sound pressure mounted
Set and free-field reciprocity method of sound pressure reference means.
The tables use the microphone sensitivity (sensitivity and free-field sound pressure sensitivity) multiplex sound pressure values
Now and delivery. Open-circuit voltage and the uniform application of the microphone output sound pressure sensitivity of the microphone in the microphone diaphragm surface
Than the sound pressure on the microphone sensitivity of the free-field microphone output open circuit voltage and the sound of this microphone is not free
Field, the sound pressure ratio at the center of the microphone sound. The sensitivity of the unit is V/Pa, generally expressed sensitivity level,
Units of dB (with 1V/Pa as a reference).
Air sound pressure measuring standard reference sound pressure sensitivity of the microphone or the free-field sensitivity by reciprocity method to achieve the sound pressure
Magnitude reproduction, and save it to reproduce the sound pressure values indirectly traceable to a current base unit ampere (A) and the length of the basic
In meters (m).
2.2 coupling cavity reciprocity law means the reference sound pressure
Coupled cavity reciprocity law means by the reference sound pressure reference microphones, coupled cavity reciprocity calibration systems and related ancillary set
Preparation, whose sound pressure values are reproduced by coupling cavity reciprocity method to accurately measure the reference microphone to achieve. Datum
LS1 and LS2 into the microphone type type, must be long-term stability assessment.
LS1 type reference microphone reciprocity calibration measurement frequency range of 2Hz ~ 10kHz, the measurement uncertainty.
2Hz ~ 10Hz, 0.20dB (k = 2);
> 10Hz ~ 6.3kHz, 0.05dB (k = 2);
> 6.3kHz ~ 10kHz, 0.10dB (k = 2).
LS2 type reference microphone reciprocity calibration measurement frequency range of 10Hz ~ 25kHz, the measurement uncertainty.
10Hz ~ 31.5Hz, 0.10dB (k = 2);
> 31.5Hz ~ 6.3kHz, 0.05dB (k = 2);
> 6.3kHz ~ 25kHz, 0.12dB (k = 2).
Transfer sound pressure values using coupled cavity reciprocity law by reference microphones and measurement standards laboratory standard microphone
Is composed of a group (of three), in coupled-cavity reciprocal reciprocity calibration measurements carried out on the reference means of acoustic pressure to give the experiment
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJG 2037-2015_English be delivered?Answer: Upon your order, we will start to translate JJG 2037-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJG 2037-2015_English with my colleagues?Answer: Yes. The purchased PDF of JJG 2037-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version JJG 2037-2015?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 2037-2015 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|