HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

JJF 2037-2023 English PDF

US$329.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJF 2037-2023: Calibration Specification for Portable Stripping Voltammetry Heavy Metal Detectors
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJF 2037-2023English329 Add to Cart 3 days [Need to translate] Calibration Specification for Portable Stripping Voltammetry Heavy Metal Detectors Valid JJF 2037-2023

Standard similar to JJF 2037-2023

JJF 1033   JJF 1030   JJG 2037   

Basic data

Standard ID JJF 2037-2023 (JJF2037-2023)
Description (Translated English) Calibration Specification for Portable Stripping Voltammetry Heavy Metal Detectors
Sector / Industry Metrology & Measurement Industry Standard
Word Count Estimation 15,113
Date of Issue 2023-03-15
Date of Implementation 2023-09-15
Issuing agency(ies) State Administration for Market Regulation

JJF 2037-2023: Calibration Specification for Portable Stripping Voltammetry Heavy Metal Detectors


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
National Metrology Technical Specifications of the People's Republic of China JJF 2037-2023 Portable stripping voltammetry for heavy metals Detector Calibration Specifications Heavy Metal Detectors 2023-09-15 Implementation Released by the State Administration for Market Regulation Portable stripping voltammetry for heavy metals Detector Calibration Specifications Responsible Unit: National Technical Committee of Physical and Chemical Metrology Main drafting unit: Hunan Institute of Metrology and Testing Xinjiang Uygur Autonomous Region Institute of Metrology and Testing Participating in the drafting unit:Shandong Jianzhu University Jiangsu Tianrui Instrument Co:, Ltd: Xiamen Standor Scientific Instrument Co:, Ltd: This specification entrusts the National Technical Committee of Physical and Chemical Metrology to be responsible for interpretation The main drafters of this specification: Ren Yun (Hunan Institute of Metrology and Testing) Peng Lihua (Hunan Institute of Metrology and Testing) Wang Jinrong (Xinjiang Uygur Autonomous Region Institute of Metrology and Testing) Participating drafters: Zhu Xiang (Hunan Institute of Metrology and Testing) Xu Sisi (Shandong Jianzhu University) Liu Zhaogui (Jiangsu Tianrui Instrument Co:, Ltd:) Yang Xiaolu (Xiamen Standor Scientific Instrument Co:, Ltd:)

Table of contents

Introduction (Ⅱ) 1 Scope(1) 2 References(1) 3 Overview(1) 4 Metrological characteristics(1) 5 Calibration conditions(2) 5:1 Environmental conditions (2) 5:2 Measuring standards and other equipment (2) 6 Calibration items and calibration methods (2) 6:1 Preparations before calibration(2) 6:2 Concentration indication error (2) 6:3 Measurement repeatability(2) 6:4 Detection limit(3) 7 Expression of Calibration Results(3) 8 Recalibration interval(3) Appendix A Calibration Raw Record Format(4) Appendix B Calibration Certificate Inner Page Format (5) Appendix C Example of Evaluation of Measurement Uncertainty of Concentration Indication Error (6)

Introduction

This specification is based on JJF 1071-2010 "National Measurement and Calibration Specification Writing Rules", JJF 1001-2011 "General "Measurement Terms and Definitions" and JJF 1059:1-2012 "Assessment and Expression of Measurement Uncertainty" were compiled: The difference between this specification and JJF 1565-2016 "Calibration Specification for Heavy Metal Water Quality Online Analyzer" is that the former is applicable Portable stripping voltammetry heavy metal detector for laboratory or field use, the latter is suitable for automatic water quality monitoring station Heavy metal online water quality monitor or analyzer: This specification is published for the first time: Portable stripping voltammetry for heavy metals Detector Calibration Specifications

1 Scope

This specification is applicable to the calibration of portable stripping voltammetry heavy metal detectors for measuring cadmium, lead and copper elements:

2 References

This specification references the following documents: JJG646-2006 pipette GB/T 6682-2008 Analytical laboratory water specifications and test methods For dated references, only the dated version applies to this specification; for undated references document, its latest version (including all amendments) applies to this specification:

3 Overview

The portable stripping voltammetry heavy metal detector (hereinafter referred to as the detector) is in a certain electrolyte solution, adding appropriate When the pre-electrolysis potential is set, after a certain period of pre-electrolysis enrichment, the metal ions to be measured are reduced and enriched on the electrode: exist The reverse scanning voltage is applied on the electrode, and the metal to be tested enriched on the electrode forms ions and dissolves into the solution: According to the solution Qualitative and quantitative detection of peak potential, peak height or peak area: The detector is mainly composed of detection unit, control unit, data acquisition unit, data processing unit and display unit, etc: grouped:

4 Metrological characteristics

The measurement characteristics of the detector are shown in Table 1: Table 1 Metrological characteristics of the detector Metrological characteristics technical indicators 0μg/L< range≤200μg/L range>200μg/L Concentration indication error is not more than ±12%, not more than ±10% Measurement repeatability ≤5% ≤4% Detection limit≤0:5μg/L ≤10μg/L Note: 1 The above indicators are not used as the basis for eligibility determination and are for reference only: 2 Select the corresponding analyte according to the intended use of the calibrated detector: 3 This indicator is applicable to cadmium, lead and copper elements:

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJF 2037-2023_English be delivered?

Answer: Upon your order, we will start to translate JJF 2037-2023_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJF 2037-2023_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 2037-2023_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.